• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Body Material
  • Cavity Size
  • Coil Nut Tightening Torque
  • Coil Type
  • Configuration
  • Division
  • Division
  • Filter Efficiency Rating
  • Flow Direction
More Filters...

Proportional Poppet Valves

Picture for category Proportional Poppet Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s selection of 2-way proportional poppet valves provide precise and dependable controls for applications that require a proportional flow control with an extremely low leakage rate. These valves are capable of handling flows up to 117 lpm (31 gpm) and pressures as high as 210 bar (3000 psi). These valves inspire confidence because of the high level of repeatable and accurate operation throughout the full control range of the valve. Parker’s 2-way proportional poppet valves are available in normally-open or normally-closed configurations and will pair with any Current Controlled Pulse Width Modulation (PWM) valve driver. These valves have uses on a variety of machinery within the agriculture, aerial, material handling, or construction markets.

Markets:
• Agriculture
• Aerial
• Construction
• Material Handling
• Miscellaneous Mobile

Features/Benefits:
• Excellent metering capability and control throughout the full flow range
• Reduced drift
• Low leak control (less than 5 dpm)
• Modular solution to applied problem
• Improved control throughout the control range

Applications:
• Applications requiring precise controls
• Variable flow applications
• Actuator control
• Motor speed control

Additional Technical Insight:
Recommended to be used with a Current Controlled Pulse Width Modulation (PWM) valve driver.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPartner AvailablePriceMaximum Operating PressureBody MaterialDivisionMinimum Operating TemperatureMaximum Kinematic ViscosityDivisionWeightMaximum Operating TemperatureOverride FunctionalityCavity SizeMaximum Inlet Pressure RatingSeal MaterialActuation TypeInstallation TorqueFor Fluid TypeFunctionFrequencyConfigurationFlow DirectionValve MaterialFilter Efficiency RatingVariation of Closing PointLeak RateOperating TemperatureFlow RateMaximum Flow RateCoil TypeHysteresisPower ConsumptionCoil Nut Tightening TorqueVariation of Opening PointMinimum Pressure DifferentialConfigurationSeal MaterialMaximum Flow Rate
FAP081C
Backordered
210 barn/aHydraulic Cartridge Systems Division-35 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems Division0.17 kg+200 °Fn/aC08-23000 psiD-Ring (Standard)Electrical30 NmMineral-based or synthetic hydraulic fluidsProportional Flow Control/Regulator100-400 HzNormally ClosedSide to Nose (2 - 1)All parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4N/A5 @ 3000 PSI (210 BAR) drops/min-37 to +93 °C7 Gal/min7 Gal/min5/8" Super Coil Low Watt (CAS)< 15%18 W1.4 Nm20-25% of Input Signal21 barNormally ClosedD-Ring (Standard)7 GAL/MIN, 27 L/MIN
FAP081CN
Backordered
3000 psin/aHydraulic Cartridge Systems Division-30 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems Division0.17 kg+250 °Fn/aC08-2210 barNitrileElectrical30 NmMineral-based or synthetic hydraulic fluidsProportional Flow Control/Regulator100-400 HzNormally ClosedSide to Nose (2 - 1)All parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4N/A5 @ 3000 PSI (210 BAR) drops/min-30 to +250 °F7 Gal/min27 L/min5/8" Super Coil Low Watt (CAS)< 15%18 W1 lb-ft20-25% of Input Signal300 psiNormally ClosedNitrile7 GAL/MIN, 27 L/MIN
FAP081CV
Backordered
3000 psin/aHydraulic Cartridge Systems Division-15 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems Division0.17 kg+204 °Cn/aC08-23000 psiFluorocarbonElectrical30 NmMineral-based or synthetic hydraulic fluidsProportional Flow Control/Regulator100-400 HzNormally ClosedSide to Nose (2 - 1)All parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4N/A5 @ 3000 PSI (210 BAR) drops/min-26 to +204 °C27 L/min7 Gal/min5/8" Super Coil Low Watt (CAS)< 15%18 W1 lb-ft20-25% of Input Signal300 psiNormally ClosedFluorocarbon7 GAL/MIN, 27 L/MIN
FAP081N
Backordered
210 barn/aHydraulic Cartridge Systems Division-37 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems Division0.48 lb+200 °Fn/aC08-2210 barD-Ring (Standard)Electrical30 NmMineral-based or synthetic hydraulic fluidsProportional Flow Control/Regulator100-400 HzNormally OpenSide to Nose (2 - 1)All parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 460-65% of Input Signal5 @ 3000 PSI (210 BAR) drops/min-37 to +93 °C40 L/min40 L/min5/8" Super Coil Low Watt (CAS)< 15%18 W1.4 NmN/A300 psiNormally OpenD-Ring (Standard)10.5 GAL/MIN, 40 L/MIN
FAP081NN
Backordered
210 barn/aHydraulic Cartridge Systems Division-34 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems Division0.22 kg+121 °Cn/aC08-23000 psiNitrileElectrical20 lb-ftMineral-based or synthetic hydraulic fluidsProportional Flow Control/Regulator100-400 HzNormally OpenSide to Nose (2 - 1)All parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 460-65% of Input Signal5 @ 3000 PSI (210 BAR) drops/min-30 to +250 °F10.5 Gal/min40 L/min5/8" Super Coil Low Watt (CAS)< 15%18 W1 lb-ftN/A300 psiNormally OpenNitrile10.5 GAL/MIN, 40 L/MIN
FAP081NV
Backordered
210 barn/aHydraulic Cartridge Systems Division-15 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems Division0.22 kg+400 °Fn/aC08-23000 psiFluorocarbonElectrical30 NmMineral-based or synthetic hydraulic fluidsProportional Flow Control/Regulator100-400 HzNormally OpenSide to Nose (2 - 1)All parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 460-65% of Input Signal5 @ 3000 PSI (210 BAR) drops/min-15 to +400 °F10.5 Gal/min40 L/min5/8" Super Coil Low Watt (CAS)< 15%18 W1.4 NmN/A21 barNormally OpenFluorocarbon10.5 GAL/MIN, 40 L/MIN
FAP101C
Backordered
3000 psin/aHydraulic Cartridge Systems Division-37 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems Division0.19 kg+93 °Cn/aC10-23000 psiD-Ring (Standard)Electrical34 NmMineral-based or synthetic hydraulic fluidsProportional Flow Control/Regulator100-400 HzNormally ClosedSide to Nose (2 - 1)All parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4N/A5 @ 3000 PSI (210 BAR) drops/min-37 to +93 °C10.5 Gal/min40 L/min5/8" Super Coil Low Watt (CAS)< 15%18 W1 lb-ft20-25% of Input Signal21 barNormally ClosedD-Ring (Standard)10.5 GAL/MIN, 40 L/MIN
FAP101CH
Backordered
210 barn/aHydraulic Cartridge Systems Division-37 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems Division0.42 lb+200 °Fn/aC10-23000 psiD-Ring (Standard)Electrical34 NmMineral-based or synthetic hydraulic fluidsProportional Flow Control/Regulator100-400 HzNormally Closed, High FlowSide to Nose (2 - 1)All parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4N/A5 @ 3000 PSI (210 BAR) drops/min-35 to +200 °F13 Gal/min40 L/min5/8" Super Coil Low Watt (CAS)< 15%18 W1.4 Nm20-25% of Input Signal300 psiNormally ClosedD-Ring (Standard)13 GAL/MIN, 45 L/MIN
FAP101CHM
Backordered
210 barn/aHydraulic Cartridge Systems Division-35 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems Division0.42 lb+93 °CScrew TypeC10-23000 psiD-Ring (Standard)Electrical, Manual25 lb-ftMineral-based or synthetic hydraulic fluidsProportional Flow Control/Regulator100-400 HzNormally Closed, High FlowSide to Nose (2 - 1)All parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4N/A5 @ 3000 PSI (210 BAR) drops/min-35 to +200 °F45 L/min40 L/min5/8" Super Coil Low Watt (CAS)< 15%18 W1.4 Nm20-25% of Input Signal300 psiNormally ClosedD-Ring (Standard)13 GAL/MIN, 45 L/MIN
FAP101CM
Backordered
3000 psin/aHydraulic Cartridge Systems Division-35 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems Division0.42 lb+200 °FScrew TypeC10-2210 barD-Ring (Standard)Electrical, Manual25 lb-ftMineral-based or synthetic hydraulic fluidsProportional Flow Control/Regulator100-400 HzNormally ClosedSide to Nose (2 - 1)All parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4N/A5 @ 3000 PSI (210 BAR) drops/min-35 to +200 °F40 L/min10.5 Gal/min5/8" Super Coil Low Watt (CAS)< 15%18 W1 lb-ft20-25% of Input Signal300 psiNormally ClosedD-Ring (Standard)10.5 GAL/MIN, 40 L/MIN
FAP101CN
Backordered
3000 psin/aHydraulic Cartridge Systems Division-34 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems Division0.42 lb+121 °Cn/aC10-2210 barNitrileElectrical25 lb-ftMineral-based or synthetic hydraulic fluidsProportional Flow Control/Regulator100-400 HzNormally ClosedSide to Nose (2 - 1)All parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4N/A5 @ 3000 PSI (210 BAR) drops/min-30 to +250 °F10.5 Gal/min40 L/min5/8" Super Coil Low Watt (CAS)< 15%18 W1 lb-ft20-25% of Input Signal21 barNormally ClosedNitrile10.5 GAL/MIN, 40 L/MIN
FAP101N
Backordered
210 barn/aHydraulic Cartridge Systems Division-37 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems Division0.23 kg+93 °Cn/aC10-23000 psiD-Ring (Standard)Electrical34 NmMineral-based or synthetic hydraulic fluidsProportional Flow Control/Regulator100-400 HzNormally OpenSide to Nose (2 - 1)All parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 460-65% of Input Signal5 @ 3000 PSI (210 BAR) drops/min-35 to +200 °F55 L/min55 L/min5/8" Super Coil Low Watt (CAS)< 15%18 W1 lb-ftN/A300 psiNormally OpenD-Ring (Standard)14.5 GAL/MIN, 55 L/MIN
FAP101NN
Backordered
3000 psin/aHydraulic Cartridge Systems Division-34 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems Division0.23 kg+121 °Cn/aC10-2210 barNitrileElectrical34 NmMineral-based or synthetic hydraulic fluidsProportional Flow Control/Regulator100-400 HzNormally OpenSide to Nose (2 - 1)All parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 460-65% of Input Signal5 @ 3000 PSI (210 BAR) drops/min-30 to +250 °F55 L/min14.5 Gal/min5/8" Super Coil Low Watt (CAS)< 15%18 W1.4 NmN/A300 psiNormally OpenNitrile14.5 GAL/MIN, 55 L/MIN
FAP101NV
Backordered
210 barn/aHydraulic Cartridge Systems Division-15 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems Division0.23 kg+400 °Fn/aC10-23000 psiFluorocarbonElectrical25 lb-ftMineral-based or synthetic hydraulic fluidsProportional Flow Control/Regulator100-400 HzNormally OpenSide to Nose (2 - 1)All parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 460-65% of Input Signal5 @ 3000 PSI (210 BAR) drops/min-26 to +204 °C14.5 Gal/min14.5 Gal/min5/8" Super Coil Low Watt (CAS)< 15%18 W1.4 NmN/A300 psiNormally OpenFluorocarbon14.5 GAL/MIN, 55 L/MIN
FAP121CN
Backordered
3000 psin/aHydraulic Cartridge Systems Division-34 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems Division0.65 lb+121 °Cn/aC12-2F3000 psiNitrileElectrical55 lb-ftMineral-based or synthetic hydraulic fluidsProportional Flow Control/Regulator100-400 HzNormally ClosedSide to Nose (2 - 1)All parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4N/A5 @ 3000 PSI (210 BAR) drops/min-30 to +250 °F21.5 Gal/min21.5 Gal/min5/8" Super Coil Low Watt (CAS)< 15%18 W1.4 Nm20-25% of Input Signal21 barNormally ClosedNitrile21.5 GAL/MIN, 81.5 L/MIN
FAP121CV
Backordered
210 barn/aHydraulic Cartridge Systems Division-15 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems Division0.65 lb+400 °Fn/aC12-2F3000 psiFluorocarbonElectrical74 NmMineral-based or synthetic hydraulic fluidsProportional Flow Control/Regulator100-400 HzNormally ClosedSide to Nose (2 - 1)All parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4N/A5 @ 3000 PSI (210 BAR) drops/min-26 to +204 °C21.5 Gal/min21.5 Gal/min5/8" Super Coil Low Watt (CAS)< 15%18 W1.4 Nm20-25% of Input Signal300 psiNormally ClosedFluorocarbon21.5 GAL/MIN, 81.5 L/MIN
FAP121NN
Backordered
210 barn/aHydraulic Cartridge Systems Division-30 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems Division0.68 lb+250 °Fn/aC12-2F210 barNitrileElectrical55 lb-ftMineral-based or synthetic hydraulic fluidsProportional Flow Control/Regulator100-400 HzNormally OpenSide to Nose (2 - 1)All parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 460-65% of Input Signal5 @ 3000 PSI (210 BAR) drops/min-30 to +250 °F26 Gal/min98.5 L/min5/8" Super Coil Low Watt (CAS)< 15%18 W1.4 NmN/A300 psiNormally OpenNitrile26 GAL/MIN, 98.5 L/MIN
FAP121NV
Backordered
210 barn/aHydraulic Cartridge Systems Division-26 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems Division0.68 lb+400 °Fn/aC12-2F3000 psiFluorocarbonElectrical55 lb-ftMineral-based or synthetic hydraulic fluidsProportional Flow Control/Regulator100-400 HzNormally OpenSide to Nose (2 - 1)All parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 460-65% of Input Signal5 @ 3000 PSI (210 BAR) drops/min-26 to +204 °C26 Gal/min26 Gal/min5/8" Super Coil Low Watt (CAS)< 15%18 W1 lb-ftN/A21 barNormally OpenFluorocarbon26 GAL/MIN, 98.5 L/MIN
FAP161CN
Backordered
3000 psin/aHydraulic Cartridge Systems Division-30 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems Division0.4 kg+121 °Cn/aC16-23000 psiNitrileElectrical80-85 lb-ftMineral-based or synthetic hydraulic fluidsProportional Flow Control/Regulator100-400 HzNormally ClosedSide to Nose (2 - 1)All parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4N/A5 @ 3000 PSI (210 BAR) drops/min-30 to +250 °F106 L/min106 L/min5/8" Super Coil Low Watt (CAS)< 15%18 W1 lb-ft20-25% of Input Signal21 barNormally ClosedNitrile28 GAL/MIN, 106 L/MIN
FAP161CV
Backordered
3000 psin/aHydraulic Cartridge Systems Division-15 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems Division0.4 kg+204 °Cn/aC16-23000 psiFluorocarbonElectrical80-85 lb-ftMineral-based or synthetic hydraulic fluidsProportional Flow Control/Regulator100-400 HzNormally ClosedSide to Nose (2 - 1)All parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4N/A5 @ 3000 PSI (210 BAR) drops/min-26 to +204 °C28 Gal/min28 Gal/min5/8" Super Coil Low Watt (CAS)< 15%18 W1.4 Nm20-25% of Input Signal300 psiNormally ClosedFluorocarbon28 GAL/MIN, 106 L/MIN