• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Body Material
  • Cavity Size
  • Coil Nut Tightening Torque
  • Coil Type
  • Configuration
  • Current
  • Division
  • Filter Efficiency Rating
  • Flow Rate
More Filters...

Directional Control Proportional Valves

Picture for category Directional Control Proportional Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s selection of 3-position, 4-way proportional directional control valves provide predictable and precise controls for applications that require bidirectional flow and controllability. These valves are capable of handling flows up to 32 lpm (8.5 gpm) and pressures as high as 350 bar (5000 psi). These valves can be used in conjunction with an external compensator finer control is required, however these valves are ideal for variable flow actuator or motor applications that need exact control with to ability to stop completely and an acceptable rate of leakage due to the inherent characteristic spool design. Parker’s 3-position, 4-way proportional directional control valves can pair with any Current Controlled Pulse Width Modulation (PWM) valve driver and can be used on a variety of mobile and industrial applications within the agriculture, construction, and manufacturing markets.

Markets:
• Agriculture
• Construction
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile

Features/Benefits:
• One piece cartridge housing
• Regulates flow proportionally to input solenoid current
• All external parts zinc plated

Applications:
• Applications requiring precise controls
• Variable flow applications
• Actuator control
• Motor speed control

Additional Technical Insight:
Recommended to be used with a Current Controlled Pulse Width Modulation (PWM) valve driver.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPartner AvailablePriceMaximum Operating PressureBody MaterialMinimum Operating TemperatureMaximum Kinematic ViscosityDivisionMaximum Operating TemperatureWeightCoil Nut Tightening TorqueCoil TypePower ConsumptionInstallation TorqueCavity SizeFor Fluid TypeFrequencyConfigurationActuation TypeOperation TypeValve MaterialFilter Efficiency RatingMaximum Inlet Pressure RatingOperating TemperatureResponse TimeMaximum Tank PressureFunctionFlow RateLeak RateSeal MaterialMaximum Flow RateOverride FunctionalityCurrentHysteresisFlow Rate AccuracyVariation of Opening PointConfigurationSeal MaterialMaximum Inlet Pressure RatingFlow RateOverride Functionality
DSP105C1M
Backordered
210 barn/a-35 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems Division+200 °F0.28 kg3 lb-ft5/8" Super Coil High Watt (CAP)28 W25 lb-ftC10-4Mineral-based or synthetic hydraulic fluids100-400 HzNormally ClosedElectrical, ManualSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4210 bar-37 to +93 °C50 ms210 barProportional Directional Control32 L/min10 @ 3000 PSI (210 BAR) cm3/minD-Ring (Standard8.5 Gal/minPush and Pull2.33 @ 12 VDC, 1.17 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input SignalNormally ClosedD-Ring (Standard)3000 PSI, 210 BAR8.5 GAL/MIN, 32 L/MINPush and Pull
DSP105C1MN
Backordered
3000 psin/a-30 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems Division+250 °F0.28 kg4.1 Nm5/8" Super Coil High Watt (CAP)28 W34 NmC10-4Mineral-based or synthetic hydraulic fluids100-400 HzNormally ClosedElectrical, ManualSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 43000 psi-34 to +121 °C50 ms210 barProportional Directional Control8.5 Gal/min10 @ 3000 PSI (210 BAR) cm3/minNitrile8.5 Gal/minPush and Pull2.33 @ 12 VDC, 1.17 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input SignalNormally ClosedNitrile3000 PSI, 210 BAR8.5 GAL/MIN, 32 L/MINPush and Pull
DSP105C4M
Backordered
210 barn/a-35 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems Division+200 °F0.57 lb4.1 Nm5/8" Super Coil High Watt (CAP)28 W25 lb-ftC10-4Mineral-based or synthetic hydraulic fluids100-400 HzFloating CenterElectrical, ManualSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 43000 psi-37 to +93 °C50 ms210 barProportional Directional Control8.5 Gal/min10 @ 3000 PSI (210 BAR) cm3/minD-Ring (Standard8.5 Gal/minPush and Pull2.33 @ 12 VDC, 1.17 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input SignalFloating CenterD-Ring (Standard)3000 PSI, 210 BAR8.5 GAL/MIN, 32 L/MINPush and Pull
DSP105C4MN
Backordered
3000 psin/a-34 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems Division+250 °F0.57 lb3 lb-ft5/8" Super Coil High Watt (CAP)28 W25 lb-ftC10-4Mineral-based or synthetic hydraulic fluids100-400 HzFloating CenterElectrical, ManualSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 43000 psi-34 to +121 °C50 ms3000 psiProportional Directional Control8.5 Gal/min10 @ 3000 PSI (210 BAR) cm3/minNitrile8.5 Gal/minPush and Pull2.33 @ 12 VDC, 1.17 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input SignalFloating CenterNitrile3000 PSI, 210 BAR8.5 GAL/MIN, 32 L/MINPush and Pull
DSP105C4V
Backordered
3000 psin/a-15 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems Division+204 °C0.28 kg3 lb-ft5/8" Super Coil High Watt (CAP)28 W34 NmC10-4Mineral-based or synthetic hydraulic fluids100-400 HzFloating CenterElectricalSolenoid OperatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4210 bar-15 to +400 °F50 ms210 barProportional Directional Control8.5 Gal/min10 @ 3000 PSI (210 BAR) cm3/minFluorocarbon8.5 Gal/minn/a2.33 @ 12 VDC, 1.17 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input SignalFloating CenterFluorocarbon3000 PSI, 210 BAR8.5 GAL/MIN, 32 L/MINN/A
GP02511V
Backordered
5000 psin/a-26 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems Division+204 °C0.15 kg3 lb-ft1/2" Super Coil14, 19 W30 NmC08-4Mineral-based or synthetic hydraulic fluids100-400 HzNormally ClosedElectrical, ManualSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4350 bar-26 to +204 °C50 ms3000 psiProportional Directional Control4, 4.5 Gal/min10 @ 3000 PSI (210 BAR) cm3/minFluorocarbon4, 4.5 Gal/minNon-Detented1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input SignalNormally ClosedFluorocarbon5000 PSI, 350 BAR4, 4.5 GAL/MIN, 15, 17 L/MINNon-Detented
GP02512V
Backordered
5000 psin/a-26 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems Division+204 °C0.15 kg4.1 Nm1/2" Super Coil14, 19 W22 lb-ftC08-4Mineral-based or synthetic hydraulic fluids100-400 HzNormally ClosedElectrical, ManualSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4350 bar-26 to +204 °C50 ms210 barProportional Directional Control4, 4.5 Gal/min10 @ 3000 PSI (210 BAR) cm3/minFluorocarbon4, 4.5 Gal/minDetented1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input SignalNormally ClosedFluorocarbon5000 PSI, 350 BAR4, 4.5 GAL/MIN, 15, 17 L/MINDetented
GP02522N
Backordered
350 barn/a-34 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems Division+121 °C0.34 lb3 lb-ft1/2" Super Coil14, 19 W30 NmC08-4Mineral-based or synthetic hydraulic fluids100-400 HzNormally ClosedElectrical, ManualSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4350 bar-30 to +250 °F50 ms3000 psiProportional Directional Control17, 21 L/min10 @ 3000 PSI (210 BAR) cm3/minNitrile4.5, 5.5 Gal/minDetented1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input SignalNormally ClosedNitrile5000 PSI, 350 BAR4.5, 5.5 GAL/MIN, 17, 21 L/MINDetented
GP02531V
Backordered
350 barn/a-26 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems Division+400 °F0.15 kg3 lb-ft1/2" Super Coil14, 19 W30 NmC08-4Mineral-based or synthetic hydraulic fluids100-400 HzFloating CenterElectrical, ManualSolenoid operated, Manually operatedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 45000 psi-26 to +204 °C50 ms3000 psiProportional Directional Control2.7, 4 Gal/min10 @ 3000 PSI (210 BAR) cm3/minFluorocarbon10, 15 L/minNon-Detented1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC ALess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input SignalFloating CenterFluorocarbon5000 PSI, 350 BAR2.7, 4 GAL/MIN, 10, 15 L/MINNon-Detented