• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Body Material
  • Division
  • For Fluid Type
  • Function
  • Maximum Flow Rate
  • Maximum Operating Pressure
  • Maximum Operating Temperature
  • Minimum Operating Temperature
  • Mounting Position
More Filters...

2/2-Way Seat Valve for Subplate Mounting - Series D4S

Picture for category 2/2-Way Seat Valve for Subplate Mounting - Series D4S

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker's highly versatile 2/2-way seat valves series D4S for subplate mounting are designed for directional control functions and feature numerous options. A large variety of poppets, springs and covers – including shuttle valves, stroke limiters, solenoid valves (VV01) and position control – allows to design individual hydraulic solutions for nominal flow up to 600 l/min.

Markets:
• Industrial

Features/Benefits:
• Proven, robust design - ensures reliable operation
• Individual configurability, various function options - useable for numerous applications
• Good price-performance ratio - fast return of investment
• Short delivery time - no warehousing necessary
• Subplate mounting according to ISO 5781
• Leak-free seat valve design
• Numerous pilot options
• 6 poppet types:
    - D4S03 - NG10
    - D4S06 - NG25
    - D4S10 - NG32

Applications:
• Suitable for general hydraulic applications
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPartner AvailablePriceDivisionMaximum Operating TemperatureMinimum Operating TemperatureMaximum Operating PressureMounting TypeSeal MaterialWeightBody MaterialProduct SeriesFor Fluid TypeMounting PositionActuation TypeMaximum Flow RateFunctionSeal MaterialOptionsSleeve TypeInput VoltagePort ConnectionCoverPilot Inlet / Drain LocationsSwitching OptionSpool TypeMinimum Opening Pressure
D4S06-9C23C2CDG0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR4.5 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot360 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRN/AAA=0.60 AC, AB=0.40 AC24 (VDC)NG25 / ISO 6264Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedPilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)Shuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual overridePoppet with throttle spool, 3° chamferA-B 1 bar, B-A 1.7 bar
D4S06-9C23C6DBG0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR4.5 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot360 L/minShuttle Valve Z-YNBRN/AAA=0.60 AC, AB=0.40 AC24 (VDC)NG25 / ISO 6264Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedPilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)Shuttle valve Z-Y and vent function: Solenoid not activated, unpressurized circulation, with manual overridePoppet with throttle spool, 3° chamferA-B 2.2 bar, B-A 3.8 bar
D4S06-9G1343B5
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateFPM4.5 kgCast IronCheck ValveWater-GlycolUnrestrictedSolenoid360 L/minn/aFPMN/AAA=0.60 AC, AB=0.40 ACnaNG25 / ISO 6264Pilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedPilot line body: External from Y (A-X orifice 1.2 / B-Y open)N/APoppet with closed bottom, 45° chamferA-B 0.6 BAR, B-A 1.0 BAR
D4S06-9GC144B1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR4.5 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid360 L/minn/aNBRN/AAA=0.95 AC, AB=0.05 ACnaNG25 / ISO 6264Pilot line cap: Standard, pilot oil = pilot drain, X closed, Y open, Z orifice 1.2, X-Y open, Y1 closedPilot line body: External from Y (A-X orifice 1.2 / B-Y open)N/APoppet with closed bottom, 45° chamferA-B 2.2 bar
D4S06-9GC3C4B1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR4.5 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot360 L/minn/aNBRN/AAA=0.60 AC, AB=0.40 ACnaNG25 / ISO 6264Pilot line cap: Standard, pilot oil = pilot drain, X closed, Y open, Z orifice 1.2, X-Y open, Y1 closedPilot line body: External from Y (A-X orifice 1.2 / B-Y open)N/APoppet with throttle spool, 3° chamferA-B 3.5 bar, B-A 6.0 bar
D4S06-9GC3C6B1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR4.5 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot360 L/minn/aNBRN/AAA=0.60 AC, AB=0.40 ACnaNG25 / ISO 6264Pilot line cap: Standard, pilot oil = pilot drain, X closed, Y open, Z orifice 1.2, X-Y open, Y1 closedPilot line body: External from Y (A-X orifice 1.2 / B-Y open)N/APoppet with throttle spool, 3° chamferA-B 2.2 bar, B-A 3.8 bar
D4S10-91111111G0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6.0 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid600 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRN/AAA=0.95 AC, AB=0.05 AC24 (VDC)NG32 / ISO 6264Pilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedPilot line body: Internal from A (A-X orifice 1.2 / B-Y open)Vent function: solenoid activated, unpressurized circulation, with manual overridePoppet with closed bottom, 15° chamferA-B 3.5 BAR
D4S10-911115B1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6.0 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot600 L/minn/aNBRN/AAA=0.95 AC, AB=0.05 ACnaNG32 / ISO 6264Pilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedPilot line body: Internal from A (A-X orifice 1.2 / B-Y open)N/APoppet with closed bottom, 15° chamferA-B 9.0 bar
D4S10-911144B1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid600 L/minn/aNBRN/AAA=0.95 AC, AB=0.05 ACnaNG32 / ISO 6264Pilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedPilot line body: Internal from A (A-X orifice 1.2 / B-Y open)N/APoppet with closed bottom, 45° chamferA-B 2.2 bar
D4S10-9123A4BKG0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid600 L/minShuttle Valve X-YNBRN/AAA=0.60 AC, AB=0.40 AC24 (VDC)NG32 / ISO 6264Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedPilot line body: Internal from A (A-X orifice 1.2 / B-Y open)Shuttle valve X-Y, position control and vent function: Solenoid not activated, unpressurized circulation, without manual override, with amplifierPoppet with safety spoolA-B 3.5 bar, B-A 6.0 bar
D4S10-9123A6BEG0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot600 L/minPosition Control and Vent Function Solenoid activated, unpressurized circulation, without manual override, with amplifier.NBRN/AAA=0.60 AC, AB=0.40 AC24 (VDC)NG32 / ISO 6264Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedPilot line body: Internal from A (A-X orifice 1.2 / B-Y open)Position control and vent function: Solenoid activated, unpressurized circulation, without manual override, with amplifierPoppet with safety spoolA-B 2.2 bar, B-A 3.8 bar
D4S10-91614111G0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot600 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRN/AAA=0.95 AC, AB=0.05 AC24 (VDC)NG32 / ISO 6264Pilot line cap: With vent function, internal pilot drain, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openPilot line body: Internal from A (A-X orifice 1.2 / B-Y open)Vent function: solenoid activated, unpressurized circulation, with manual overridePoppet with closed bottom, 45° chamferA-B 3.5 BAR
D4S10-91614409G0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot600 L/minVent Function Solenoid not activated, unpressurized circulation, with manual override.NBRN/AAA=0.95 AC, AB=0.05 AC24 (VDC)NG32 / ISO 6264Pilot line cap: With vent function, internal pilot drain, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openPilot line body: Internal from A (A-X orifice 1.2 / B-Y open)Vent function: Solenoid not activated, unpressurized circulation, with manual overridePoppet with closed bottom, 45° chamferA-B 2.2 bar
D4S10-91614411W30B1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot600 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRN/AAA=0.95 AC, AB=0.05 AC110/120 (VAC), 50/60 (Hz)NG32 / ISO 6264Pilot line cap: With vent function, internal pilot drain, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openPilot line body: Internal from A (A-X orifice 1.2 / B-Y open)Vent function: solenoid activated, unpressurized circulation, with manual overridePoppet with closed bottom, 45° chamferA-B 2.2 bar
D4S10-91634111G0QB1
Backordered
Hydraulic Valve Systems Division Europe60 °C-20 °C350 barSubplateNBR6.0 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid600 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRnaAA=0.60 AC, AB=0.40 AC24 (VDC)NG32 / ISO 6264Pilot line cap: With vent function, internal pilot drain, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openPilot line body: Internal from A (A-X orifice 1.2 / B-Y open)Vent function: solenoid activated, unpressurized circulation, with manual overridePoppet with closed bottom, 45° chamferA-B 6.5 bar, B-A 11 bar
D4S10-921111B1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid600 L/minn/aNBRN/AAA=0.95 AC, AB=0.05 ACnaNG32 / ISO 6264Pilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedPilot line body: External from X (A-X closed / B-Y open)N/APoppet with closed bottom, 15° chamferA-B 3.5 BAR
D4S10-921342B5
Backordered
Hydraulic Valve Systems Division Europe60 °C-20 °C350 barSubplateFPM6.0 kgCast IronCheck ValveWater-GlycolUnrestrictedPilot600 L/minn/aFPMnaAA=0.60 AC, AB=0.40 ACnaNG32 / ISO 6264Pilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedPilot line body: External from X (A-X closed / B-Y open)naPoppet with closed bottom, 45° chamferA-B 1 bar, B-A 1.7 bar
D4S10-9213C4B1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6.0 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot600 L/minn/aNBRN/AAA=0.60 AC, AB=0.40 ACnaNG32 / ISO 6264Pilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedPilot line body: External from X (A-X closed / B-Y open)N/APoppet with throttle spool, 3° chamferA-B 3.5 bar, B-A 6.0 bar
D4S10-92234411W30B1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot600 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRN/AAA=0.60 AC, AB=0.40 AC110/120 (VAC), 50/60 (Hz)NG32 / ISO 6264Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedPilot line body: External from X (A-X closed / B-Y open)Vent function: solenoid activated, unpressurized circulation, with manual overridePoppet with closed bottom, 45° chamferA-B 3.5 bar, B-A 6.0 bar
D4S10-92634411G0QB1
Backordered
Hydraulic Valve Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot600 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRnaAA=0.60 AC, AB=0.40 AC24 (VDC)NG32 / ISO 6264Pilot line cap: With vent function, internal pilot drain, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openPilot line body: External from X (A-X closed / B-Y open)Vent function: solenoid activated, unpressurized circulation, with manual overridePoppet with closed bottom, 45° chamferA-B 3.5 bar, B-A 6.0 bar