• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Body Material
  • Division
  • For Fluid Type
  • Function
  • Maximum Flow Rate
  • Maximum Operating Pressure
  • Maximum Operating Temperature
  • Minimum Operating Temperature
  • Mounting Position
More Filters...

2/2-Way Seat Valve for Subplate Mounting - Series D4S

Picture for category 2/2-Way Seat Valve for Subplate Mounting - Series D4S

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker's highly versatile 2/2-way seat valves series D4S for subplate mounting are designed for directional control functions and feature numerous options. A large variety of poppets, springs and covers – including shuttle valves, stroke limiters, solenoid valves (VV01) and position control – allows to design individual hydraulic solutions for nominal flow up to 600 l/min.

Markets:
• Industrial

Features/Benefits:
• Proven, robust design - ensures reliable operation
• Individual configurability, various function options - useable for numerous applications
• Good price-performance ratio - fast return of investment
• Short delivery time - no warehousing necessary
• Subplate mounting according to ISO 5781
• Leak-free seat valve design
• Numerous pilot options
• 6 poppet types:
    - D4S03 - NG10
    - D4S06 - NG25
    - D4S10 - NG32

Applications:
• Suitable for general hydraulic applications
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPartner AvailablePriceDivisionMaximum Operating TemperatureMinimum Operating TemperatureMaximum Operating PressureMounting TypeSeal MaterialWeightBody MaterialProduct SeriesFor Fluid TypeMounting PositionActuation TypeMaximum Flow RateFunctionSeal MaterialPort ConnectionOptionsSpool TypeInput VoltageSwitching OptionPilot Inlet / Drain LocationsSleeve TypeCoverMinimum Opening Pressure
D4S10-9A214111G0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid600 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRNG32 / ISO 6264N/APoppet with closed bottom, 45° chamfer24 (VDC)Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)AA=0.95 AC, AB=0.05 ACPilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedA-B 3.5 BAR
D4S10-9A214411G0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid600 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRNG32 / ISO 6264N/APoppet with closed bottom, 45° chamfer24 (VDC)Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)AA=0.95 AC, AB=0.05 ACPilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedA-B 2.2 bar
D4S10-9A23C211G0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid600 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRNG32 / ISO 6264N/APoppet with throttle spool, 3° chamfer24 (VDC)Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)AA=0.60 AC, AB=0.40 ACPilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedA-B 1 bar, B-A 1.7 bar
D4S10-9A514209G0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot600 L/minVent Function Solenoid not activated, unpressurized circulation, with manual override.NBRNG32 / ISO 6264N/APoppet with closed bottom, 45° chamfer24 (VDC)Vent function: Solenoid not activated, unpressurized circulation, with manual overridePilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)AA=0.95 AC, AB=0.05 ACPilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openA-B 0.5 bar
D4S10-9A514211G0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid600 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRNG32 / ISO 6264N/APoppet with closed bottom, 45° chamfer24 (VDC)Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)AA=0.95 AC, AB=0.05 ACPilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openA-B 0.5 bar
D4S10-9A514211W31B1
Backordered
Hydraulic Valve Systems Division Europe60 °C-20 °C350 barSubplateNBR6.0 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot600 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRNG32 / ISO 6264naPoppet with closed bottom, 45° chamfer230/240 (VAC), 50/60 (Hz)Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)AA=0.95 AC, AB=0.05 ACPilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openA-B 0.5 bar
D4S10-9A514609W30B1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid600 L/minVent Function Solenoid not activated, unpressurized circulation, with manual override.NBRNG32 / ISO 6264N/APoppet with closed bottom, 45° chamfer110/120 (VAC), 50/60 (Hz)Vent function: Solenoid not activated, unpressurized circulation, with manual overridePilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)AA=0.95 AC, AB=0.05 ACPilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openA-B 1.2 bar
D4S10-9A534411G0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot600 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRNG32 / ISO 6264N/APoppet with closed bottom, 45° chamfer24 (VDC)Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)AA=0.60 AC, AB=0.40 ACPilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openA-B 3.5 bar, B-A 6.0 bar
D4S10-9A534611W31B1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot600 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRNG32 / ISO 6264N/APoppet with closed bottom, 45° chamfer230/240 (VAC), 50/60 (Hz)Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)AA=0.60 AC, AB=0.40 ACPilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openA-B 2.2 bar, B-A 3.8 bar
D4S10-9A53A2BEG0QB1013
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid600 L/minPosition Control and Vent Function Solenoid activated, unpressurized circulation, without manual override, with amplifier.NBRNG32 / ISO 6264Cover for end position controlPoppet with safety spool24 (VDC)Position control and vent function: Solenoid activated, unpressurized circulation, without manual override, with amplifierPilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)AA=0.60 AC, AB=0.40 ACPilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openA-B 1 bar, B-A 1.7 bar
D4S10-9A53A4BEG0QB1013
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot600 L/minPosition Control and Vent Function Solenoid activated, unpressurized circulation, without manual override, with amplifier.NBRNG32 / ISO 6264Cover for end position controlPoppet with safety spool24 (VDC)Position control and vent function: Solenoid activated, unpressurized circulation, without manual override, with amplifierPilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)AA=0.60 AC, AB=0.40 ACPilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openA-B 3.5 bar, B-A 6.0 bar
D4S10-9A53A6EEG0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6.0 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot600 L/minVent Function Solenoid not activated, unpressurized circulation, without manual override and position control with amplifier.NBRNG32 / ISO 6264N/APoppet with safety spool24 (VDC)Vent function: Solenoid not activated, unpressurized circulation, without manual override and position control with amplifierPilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)AA=0.60 AC, AB=0.40 ACPilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openA-B 2.2 bar, B-A 3.8 bar
D4S10-9A53B209G0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid600 L/minVent Function Solenoid not activated, unpressurized circulation, with manual override.NBRNG32 / ISO 6264N/APoppet with throttle spool, 10° chamfer24 (VDC)Vent function: Solenoid not activated, unpressurized circulation, with manual overridePilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)AA=0.60 AC, AB=0.40 ACPilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openA-B 1 bar, B-A 1.7 bar
D4S10-9A53B411W30B1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid600 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRNG32 / ISO 6264N/APoppet with throttle spool, 10° chamfer110/120 (VAC), 50/60 (Hz)Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)AA=0.60 AC, AB=0.40 ACPilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openA-B 3.5 bar, B-A 6.0 bar
D4S10-9B1116B1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot600 L/minn/aNBRNG32 / ISO 6264N/APoppet with closed bottom, 15° chamfernaN/APilot line body: External from X (A-X closed / B-Y closed)AA=0.95 AC, AB=0.05 ACPilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedA-B 1.2 bar
D4S10-9B211311G0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot600 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRNG32 / ISO 6264N/APoppet with closed bottom, 15° chamfer24 (VDC)Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line body: External from X (A-X closed / B-Y closed)AA=0.95 AC, AB=0.05 ACPilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedA-B 0.3 bar
D4S10-9B33B6B1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot600 L/minn/aNBRNG32 / ISO 6264N/APoppet with throttle spool, 10° chamfernaN/APilot line body: External from X (A-X closed / B-Y closed)AA=0.60 AC, AB=0.40 ACPilot line cap: With stroke limiter, pilot oil = pilot drain, X orifice 1.2, Y closedA-B 2.2 bar, B-A 3.8 bar
D4S10-9B511311G0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid600 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRNG32 / ISO 6264N/APoppet with closed bottom, 15° chamfer24 (VDC)Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line body: External from X (A-X closed / B-Y closed)AA=0.95 AC, AB=0.05 ACPilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openA-B 0.3 bar
D4S10-9B512409G0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot600 L/minVent Function Solenoid not activated, unpressurized circulation, with manual override.NBRNG32 / ISO 6264N/APoppet with orifice, 15° chamfer24 (VDC)Vent function: Solenoid not activated, unpressurized circulation, with manual overridePilot line body: External from X (A-X closed / B-Y closed)AA=0.95 AC, AB=0.05 ACPilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openA-B 2.2 bar
D4S10-9B512411G0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot600 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRNG32 / ISO 6264N/APoppet with orifice, 15° chamfer24 (VDC)Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line body: External from X (A-X closed / B-Y closed)AA=0.95 AC, AB=0.05 ACPilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openA-B 2.2 bar