Parker's highly versatile 2/2-way seat valves series D4S for subplate mounting are designed for directional control functions and feature numerous options. A large variety of poppets, springs and covers – including shuttle valves, stroke limiters, solenoid valves (VV01) and position control – allows to design individual hydraulic solutions for nominal flow up to 600 l/min.

Markets:
• Industrial

Features/Benefits:
• Proven, robust design - ensures reliable operation
• Individual configurability, various function options - useable for numerous applications
• Good price-performance ratio - fast return of investment
• Short delivery time - no warehousing necessary
• Subplate mounting according to ISO 5781
• Leak-free seat valve design
• Numerous pilot options
• 6 poppet types:
    - D4S03 - NG10
    - D4S06 - NG25
    - D4S10 - NG32

Applications:
• Suitable for general hydraulic applications
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPartner AvailablePriceDivisionMaximum Operating TemperatureMinimum Operating TemperatureMaximum Operating PressureMounting TypeSeal MaterialWeightBody MaterialProduct SeriesFor Fluid TypeMounting PositionActuation TypeMaximum Flow RateFunctionSeal MaterialSwitching OptionInput VoltagePort ConnectionPilot Inlet / Drain LocationsOptionsCoverSpool TypeSleeve TypeMinimum Opening Pressure
016-96235-0
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot600 L/minn/aNBRN/AnaNG32 / ISO 6264Pilot line body: External from X (A-X closed / B-Y open)N/APilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedPoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 3.5 bar, B-A 6.0 bar
026-21865-0
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot600 L/minn/aNBRN/AnaNG32 / ISO 6264Pilot line body: External from X (A-X closed / B-Y open)N/APilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedPoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACA-B 2.2 bar
026-21933-0
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid600 L/minn/aNBRN/AnaNG32 / ISO 6264Pilot line body: External from X (A-X closed / B-Y open)N/APilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedPoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACA-B 0.3 bar
026-23728-0
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR4.5 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid360 L/minn/aNBRN/AnaNG25 / ISO 6264Pilot line body: External from X (A-X closed / B-Y open)N/APilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedPoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACA-B 2.2 bar
026-23757-0
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR4.5 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid360 L/minn/aNBRN/AnaNG25 / ISO 6264Pilot line body: External from X (A-X closed / B-Y open)N/APilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedPoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 3.5 bar, B-A 6.0 bar
026-23833-0
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR4.5 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid360 L/minn/aNBRN/AnaNG25 / ISO 6264Pilot line body: External from X (A-X closed / B-Y open)N/APilot line cap: With stroke limiter, pilot oil = pilot drain, X orifice 1.2, Y closedPoppet with throttle spool, 10° chamferAA=0.60 AC, AB=0.40 ACA-B 3.5 bar, B-A 6.0 bar
026-23876-0
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR4.5 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot360 L/minn/aNBRN/AnaNG25 / ISO 6264Pilot line body: External from X (A-X closed / B-Y open)N/APilot line cap: With stroke limiter, pilot oil = pilot drain, X orifice 1.2, Y closedPoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 3.5 bar, B-A 6.0 bar
026-23949-0
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR2.7 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot180 L/minn/aNBRN/AnaNG10 / ISO 6264Pilot line body: External from X (A-X closed / B-Y open)N/APilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedPoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 4.0 bar, B-A 5.5 bar
026-24112-0
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR2.7 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot180 L/minn/aNBRN/AnaNG10 / ISO 6264Pilot line body: Internal from A (A-X orifice 1.2 / B-Y open)N/APilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedPoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACA-B 2.2 bar
026-24644-0
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid600 L/minn/aNBRN/AnaNG32 / ISO 6264Pilot line body: External from X (A-X closed / B-Y open)N/APilot line cap: With stroke limiter, pilot oil = pilot drain, X orifice 1.2, Y closedPoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 3.5 bar, B-A 6.0 bar
026-24661-0
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot600 L/minn/aNBRN/AnaNG32 / ISO 6264Pilot line body: External from X (A-X closed / B-Y open)N/APilot line cap: With stroke limiter, pilot oil = pilot drain, X orifice 1.2, Y closedPoppet with throttle spool, 10° chamferAA=0.60 AC, AB=0.40 ACA-B 0.6 BAR, B-A 1.0 BAR
026-24807-0
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR4.5 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot360 L/minn/aNBRN/AnaNG25 / ISO 6264Pilot line body: Internal from B (A-X closed / B-Y orifice 1.2)N/APilot line cap: Standard, pilot oil = pilot drain, X closed, Y open, Z orifice 1.2, X-Y open, Y1 closedPoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACA-B 2.2 bar
026-28719-0
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR4.5 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid360 L/minn/aNBRN/AnaNG25 / ISO 6264Pilot line body: External from X (A-X closed / B-Y open)N/APilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedPoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACA-B 0.5 bar
026-28768-0
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid600 L/minn/aNBRN/AnaNG32 / ISO 6264Pilot line body: External from X (A-X closed / B-Y open)N/APilot line cap: With stroke limiter, pilot oil = pilot drain, X orifice 1.2, Y closedPoppet with throttle spool, 10° chamferAA=0.60 AC, AB=0.40 ACA-B 3.5 bar, B-A 6.0 bar
026-30747-H
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR4.5 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot360 L/minVent Function Solenoid not activated, unpressurized circulation, with manual override.NBRVent function: Solenoid not activated, unpressurized circulation, with manual override24 (VDC)NG25 / ISO 6264Pilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)N/APilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openPoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACA-B 2.2 bar
026-36020-H
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR2.7 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot180 L/minVent Function Solenoid not activated, unpressurized circulation, with manual override.NBRVent function: Solenoid not activated, unpressurized circulation, with manual override24 (VDC)NG10 / ISO 6264Pilot line body: Internal from A (A-X orifice 1.2 / B-Y open)N/APilot line cap: With vent function, internal pilot drain, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openPoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 4.0 bar, B-A 5.5 bar
026-36046-S
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR4.5 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot360 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRVent function: solenoid activated, unpressurized circulation, with manual override230/240 (VAC), 50/60 (Hz)NG25 / ISO 6264Pilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)N/APilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openPoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACA-B 2.2 bar
026-36046-T
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR4.5 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot360 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRVent function: solenoid activated, unpressurized circulation, with manual override110/120 (VAC), 50/60 (Hz)NG25 / ISO 6264Pilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)N/APilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openPoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACA-B 2.2 bar
026-36048-H
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR4.5 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot360 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRVent function: solenoid activated, unpressurized circulation, with manual override24 (VDC)NG25 / ISO 6264Pilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)N/APilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openPoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 3.5 bar, B-A 6.0 bar
026-36562-H
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid600 L/minShuttle Valve X-YNBRShuttle valve X-Y and vent function: Solenoid not activated, unpressurized circulation, with manual override24 (VDC)NG32 / ISO 6264Pilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)N/APilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedPoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 3.5 bar, B-A 6.0 bar