• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Body Material
  • Division
  • For Fluid Type
  • Function
  • Maximum Flow Rate
  • Maximum Operating Pressure
  • Maximum Operating Temperature
  • Minimum Operating Temperature
  • Mounting Position
More Filters...

2/2-Way Seat Valve for Subplate Mounting - Series D4S

Picture for category 2/2-Way Seat Valve for Subplate Mounting - Series D4S

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker's highly versatile 2/2-way seat valves series D4S for subplate mounting are designed for directional control functions and feature numerous options. A large variety of poppets, springs and covers – including shuttle valves, stroke limiters, solenoid valves (VV01) and position control – allows to design individual hydraulic solutions for nominal flow up to 600 l/min.

Markets:
• Industrial

Features/Benefits:
• Proven, robust design - ensures reliable operation
• Individual configurability, various function options - useable for numerous applications
• Good price-performance ratio - fast return of investment
• Short delivery time - no warehousing necessary
• Subplate mounting according to ISO 5781
• Leak-free seat valve design
• Numerous pilot options
• 6 poppet types:
    - D4S03 - NG10
    - D4S06 - NG25
    - D4S10 - NG32

Applications:
• Suitable for general hydraulic applications
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPartner AvailablePriceDivisionMaximum Operating TemperatureMinimum Operating TemperatureMaximum Operating PressureMounting TypeSeal MaterialWeightBody MaterialProduct SeriesFor Fluid TypeMounting PositionActuation TypeMaximum Flow RateFunctionSeal MaterialPort ConnectionOptionsSpool TypeInput VoltageSwitching OptionCoverSleeve TypeMinimum Opening PressurePilot Inlet / Drain Locations
D4S10-9B514209G0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid600 L/minVent Function Solenoid not activated, unpressurized circulation, with manual override.NBRNG32 / ISO 6264N/APoppet with closed bottom, 45° chamfer24 (VDC)Vent function: Solenoid not activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openAA=0.95 AC, AB=0.05 ACA-B 0.5 barPilot line body: External from X (A-X closed / B-Y closed)
D4S10-9B514409G0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot600 L/minVent Function Solenoid not activated, unpressurized circulation, with manual override.NBRNG32 / ISO 6264N/APoppet with closed bottom, 45° chamfer24 (VDC)Vent function: Solenoid not activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openAA=0.95 AC, AB=0.05 ACA-B 2.2 barPilot line body: External from X (A-X closed / B-Y closed)
D4S10-9B514411G0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot600 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRNG32 / ISO 6264N/APoppet with closed bottom, 45° chamfer24 (VDC)Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openAA=0.95 AC, AB=0.05 ACA-B 2.2 barPilot line body: External from X (A-X closed / B-Y closed)
D4S10-9B534409G0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid600 L/minVent Function Solenoid not activated, unpressurized circulation, with manual override.NBRNG32 / ISO 6264N/APoppet with closed bottom, 45° chamfer24 (VDC)Vent function: Solenoid not activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openAA=0.60 AC, AB=0.40 ACA-B 3.5 bar, B-A 6.0 barPilot line body: External from X (A-X closed / B-Y closed)
D4S10-9B534411G0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid600 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRNG32 / ISO 6264N/APoppet with closed bottom, 45° chamfer24 (VDC)Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openAA=0.60 AC, AB=0.40 ACA-B 3.5 bar, B-A 6.0 barPilot line body: External from X (A-X closed / B-Y closed)
D4S10-9C2112CDW30B1
Backordered
Hydraulic Valve Systems Division Europe60 °C-20 °C350 barSubplateNBR6.0 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid600 L/minShuttle Valve X-YNBRNG32 / ISO 6264naPoppet with closed bottom, 15° chamfer110/120 (VAC), 50/60 (Hz)Shuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedAA=0.95 AC, AB=0.05 ACA-B 0.5 barPilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)
D4S10-9C2141CDG0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6.0 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid600 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRNG32 / ISO 6264N/APoppet with closed bottom, 45° chamfer24 (VDC)Shuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedAA=0.95 AC, AB=0.05 ACA-B 3.5 BARPilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)
D4S10-9C2144CBG0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot600 L/minShuttle Valve X-YNBRNG32 / ISO 6264N/APoppet with closed bottom, 45° chamfer24 (VDC)Shuttle valve X-Y and vent function: Solenoid not activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedAA=0.95 AC, AB=0.05 ACA-B 2.2 barPilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)
D4S10-9C2145CDG0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid600 L/minShuttle Valve X-YNBRNG32 / ISO 6264N/APoppet with closed bottom, 45° chamfer24 (VDC)Shuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedAA=0.95 AC, AB=0.05 ACA-B 9.0 barPilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)
D4S10-9C2341CDG0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid600 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRNG32 / ISO 6264N/APoppet with closed bottom, 45° chamfer24 (VDC)Shuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedAA=0.60 AC, AB=0.40 ACA-B 6.5 bar, B-A 11 barPilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)
D4S10-9C2342CBW30B1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6.0 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot600 L/minShuttle Valve X-YNBRNG32 / ISO 6265N/APoppet with closed bottom, 45° chamfer110/120 (VAC), 50/60 (Hz)Shuttle valve X-Y and vent function: Solenoid not activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedAA=0.60 AC, AB=0.40 ACA-B 1 bar, B-A 1.7 barPilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)
D4S10-9C2342CDG0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot600 L/minShuttle Valve X-YNBRNG32 / ISO 6264N/APoppet with closed bottom, 45° chamfer24 (VDC)Shuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedAA=0.60 AC, AB=0.40 ACA-B 1 bar, B-A 1.7 barPilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)
D4S10-9C2343CDG0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid600 L/minShuttle Valve X-YNBRNG32 / ISO 6264N/APoppet with closed bottom, 45° chamfer24 (VDC)Shuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedAA=0.60 AC, AB=0.40 ACA-B 0.6 BAR, B-A 1.0 BARPilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)
D4S10-9C2344CDG0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot600 L/minShuttle Valve X-YNBRNG32 / ISO 6264N/APoppet with closed bottom, 45° chamfer24 (VDC)Shuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedAA=0.60 AC, AB=0.40 ACA-B 3.5 bar, B-A 6.0 barPilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)
D4S10-9C2344CDW30B1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot600 L/minShuttle Valve X-YNBRNG32 / ISO 6264N/APoppet with closed bottom, 45° chamfer110/120 (VAC), 50/60 (Hz)Shuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedAA=0.60 AC, AB=0.40 ACA-B 3.5 bar, B-A 6.0 barPilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)
D4S10-9C23A4BKG0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6.0 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid600 L/minVent Function Solenoid not activated, unpressurized circulation, without manual override, with amplifier.NBRNG32 / ISO 6264N/APoppet with safety spool24 (VDC)Shuttle valve X-Y, position control and vent function: Solenoid not activated, unpressurized circulation, without manual override, with amplifierPilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedAA=0.60 AC, AB=0.40 ACA-B 3.5 bar, B-A 6.0 barPilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)
D4S10-9C23B4CDG0QB1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid600 L/minVent Function Solenoid activated, unpressurized circulation, with manual override.NBRNG32 / ISO 6264N/APoppet with throttle spool, 10° chamfer24 (VDC)Shuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedAA=0.60 AC, AB=0.40 ACA-B 3.5 bar, B-A 6.0 barPilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)
D4S10-9D1344B5
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6.0 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot600 L/minn/aFPMNG32 / ISO 6264N/APoppet with closed bottom, 45° chamfernaN/APilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedAA=0.60 AC, AB=0.40 ACA-B 3.5 bar, B-A 6.0 barPilot line body: Internal from B (A-X closed / B-Y orifice 1.2)
D4S10-9D3114B1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedSolenoid600 L/minn/aNBRNG32 / ISO 6264N/APoppet with closed bottom, 15° chamfernaN/APilot line cap: With stroke limiter, pilot oil = pilot drain, X orifice 1.2, Y closedAA=0.95 AC, AB=0.05 ACA-B 2.2 barPilot line body: Internal from B (A-X closed / B-Y orifice 1.2)
D4S10-9D4144B1
Backordered
Industrial Systems Division Europe60 °C-20 °C350 barSubplateNBR6 kgCast IronCheck ValveHydraulic Oil According to DIN 51524UnrestrictedPilot600 L/minn/aNBRNG32 / ISO 6264N/APoppet with closed bottom, 45° chamfernaN/APilot line cap: With stroke limiter, pilot oil = pilot drain, X closed, Y orifice 1.2AA=0.95 AC, AB=0.05 ACA-B 2.2 barPilot line body: Internal from B (A-X closed / B-Y orifice 1.2)