2/2-Way Seat Valve for Subplate Mounting - Series D4S

Picture for category 2/2-Way Seat Valve for Subplate Mounting - Series D4S

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker's highly versatile 2/2-way seat valves series D4S for subplate mounting are designed for directional control functions and feature numerous options. A large variety of poppets, springs and covers – including shuttle valves, stroke limiters, solenoid valves (VV01) and position control – allows to design individual hydraulic solutions for nominal flow up to 600 l/min.

Markets:
• Industrial

Features/Benefits:
• Proven, robust design - ensures reliable operation
• Individual configurability, various function options - useable for numerous applications
• Good price-performance ratio - fast return of investment
• Short delivery time - no warehousing necessary
• Subplate mounting according to ISO 5781
• Leak-free seat valve design
• Numerous pilot options
• 6 poppet types:
    - D4S03 - NG10
    - D4S06 - NG25
    - D4S10 - NG32

Applications:
• Suitable for general hydraulic applications
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPartner AvailablePriceWeightBody MaterialMounting TypeSeal MaterialActuation TypeProduct SeriesMaximum Flow RateDivisionMaximum Operating PressureMaximum Operating TemperatureMinimum Operating TemperatureFor Fluid TypeFunctionMounting PositionSeal MaterialPort ConnectionSwitching OptionCoverOptionsSpool TypeSleeve TypeInput VoltageMinimum Opening PressurePilot Inlet / Drain Locations
026-67821-H
Backordered
6 kgCast IronSubplateNBRPilotCheck Valve600 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CHydraulic Oil According to DIN 51524Vent Function Solenoid activated, unpressurized circulation, with manual override.UnrestrictedNBRNG32 / ISO 6264Shuttle valve Z-Y and vent function: Solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 AC24 (VDC)A-B 3.5 bar, B-A 6.0 barPilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)
026-67949-0
Backordered
4.5 kgCast IronSubplateNBRPilotCheck Valve360 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CHydraulic Oil According to DIN 51524n/aUnrestrictedNBRNG25 / ISO 6264N/APilot line cap: With stroke limiter, pilot oil = pilot drain, X orifice 1.2, Y closedN/APoppet with throttle spool, 10° chamferAA=0.60 AC, AB=0.40 ACnaA-B 2.2 bar, B-A 3.8 barPilot line body: Internal from A (A-X orifice 1.2 / B-Y open)
026-70909-H
Backordered
6 kgCast IronSubplateNBRPilotCheck Valve600 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CHydraulic Oil According to DIN 51524Shuttle Valve X-YUnrestrictedNBRNG32 / ISO 6264Shuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 AC24 (VDC)A-B 0.6 BAR, B-A 1.0 BARPilot line body: Internal from B (A-X closed / B-Y orifice 1.2)
026-70949-H
Backordered
6 kgCast IronSubplateNBRPilotCheck Valve600 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CHydraulic Oil According to DIN 51524Vent Function Solenoid activated, unpressurized circulation, with manual override.UnrestrictedNBRNG32 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 AC24 (VDC)A-B 16.0 bar, B-A 28.0 barPilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)
026-70976-H
Backordered
6 kgCast IronSubplateNBRPilotCheck Valve600 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CHydraulic Oil According to DIN 51524Vent Function Solenoid activated, unpressurized circulation, with manual override.UnrestrictedNBRNG32 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 AC24 (VDC)A-B 3.5 bar, B-A 6.0 barPilot line body: Internal from A (A-X orifice 1.2 / B-Y open)
026-75836-T
Backordered
4.5 kgCast IronSubplateNBRPilotCheck Valve360 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CHydraulic Oil According to DIN 51524Vent Function Solenoid activated, unpressurized circulation, with manual override.UnrestrictedNBRNG25 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 15° chamferAA=0.95 AC, AB=0.05 AC110/120 (VAC), 50/60 (Hz)A-B 2.2 barPilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)
026-95556-H
Backordered
4.5 kgCast IronSubplateFPMSolenoidCheck Valve360 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CWater-GlycolVent Function Solenoid activated, unpressurized circulation, with manual override.UnrestrictedFPMNG25 / ISO 6264Shuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 AC24 (VDC)A-B 3.5 bar, B-A 6.0 barPilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)
026-96259-0
Backordered
6 kgCast IronSubplateNBRPilotCheck Valve600 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CHydraulic Oil According to DIN 51524n/aUnrestrictedNBRNG32 / ISO 6264N/APilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACnaA-B 3.5 bar, B-A 6.0 barPilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)
026-96484-H
Backordered
6 kgCast IronSubplateNBRSolenoidCheck Valve600 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CHydraulic Oil According to DIN 51524Vent Function Solenoid activated, unpressurized circulation, with manual override.UnrestrictedNBRNG32 / ISO 6264Shuttle valve Z-Y and vent function: Solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 AC24 (VDC)A-B 3.5 bar, B-A 6.0 barPilot line body: Internal from B (A-X closed / B-Y orifice 1.2)
026-96516-H
Backordered
4.5 kgCast IronSubplateNBRSolenoidCheck Valve360 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CHydraulic Oil According to DIN 51524Position Control and Vent Function Solenoid activated, unpressurized circulation, without manual override, with amplifier.UnrestrictedNBRNG25 / ISO 6264Position control and vent function: Solenoid activated, unpressurized circulation, without manual override, with amplifierPilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with safety spoolAA=0.60 AC, AB=0.40 AC24 (VDC)A-B 1 bar, B-A 1.7 barPilot line body: External from X (A-X closed / B-Y open)
026-96518-H
Backordered
6 kgCast IronSubplateNBRPilotCheck Valve600 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CHydraulic Oil According to DIN 51524Position Control and Vent Function Solenoid activated, unpressurized circulation, without manual override, with amplifier.UnrestrictedNBRNG32 / ISO 6264Position control and vent function: Solenoid activated, unpressurized circulation, without manual override, with amplifierPilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with safety spoolAA=0.60 AC, AB=0.40 AC24 (VDC)A-B 0.6 BAR, B-A 1.0 BARPilot line body: External from X (A-X closed / B-Y open)
026-96673-0
Backordered
2.7 kgCast IronSubplateNBRPilotCheck Valve180 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CHydraulic Oil According to DIN 51524n/aUnrestrictedNBRNG10 / ISO 6264N/APilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACnaA-B 3.0 barPilot line body: Internal from A (A-X orifice 1.2 / B-Y open)
026-99107-T
Backordered
6 kgCast IronSubplateNBRSolenoidCheck Valve600 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CHydraulic Oil According to DIN 51524Vent Function Solenoid not activated, unpressurized circulation, with manual override.UnrestrictedNBRNG32 / ISO 6264Vent function: Solenoid not activated, unpressurized circulation, with manual overridePilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 AC110/120 (VAC), 50/60 (Hz)A-B 0.6 BAR, B-A 1.0 BARPilot line body: Internal from A (A-X orifice 1.2 / B-Y open)
026-99402-0
Backordered
4.5 kgCast IronSubplateNBRSolenoidCheck Valve360 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CHydraulic Oil According to DIN 51524n/aUnrestrictedNBRNG25 / ISO 6264N/APilot line cap: With stroke limiter, pilot oil = pilot drain, X orifice 1.2, Y closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACnaA-B 1 bar, B-A 1.7 barPilot line body: External from X (A-X closed / B-Y open)
026-99453-0
Backordered
4.5 kgCast IronSubplateNBRSolenoidCheck Valve360 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CHydraulic Oil According to DIN 51524n/aUnrestrictedNBRNG25 / ISO 6264N/APilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedN/APoppet with throttle spool, 10° chamferAA=0.60 AC, AB=0.40 ACnaA-B 2.2 bar, B-A 3.8 barPilot line body: External from X (A-X closed / B-Y closed)
026-99487-0
Backordered
6 kgCast IronSubplateNBRSolenoidCheck Valve600 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CHydraulic Oil According to DIN 51524n/aUnrestrictedNBRNG32 / ISO 6264N/APilot line cap: With stroke limiter, pilot oil = pilot drain, X orifice 1.2, Y closedN/APoppet with throttle spool, 3° chamferAA=0.60 AC, AB=0.40 ACnaA-B 3.5 bar, B-A 6.0 barPilot line body: External from X (A-X closed / B-Y open)
026-99492-H
Backordered
6 kgCast IronSubplateFPMPilotCheck Valve600 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CWater-GlycolVent Function Solenoid activated, unpressurized circulation, with manual override.UnrestrictedFPMNG32 / ISO 6264Shuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual overridePilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 AC24 (VDC)A-B 3.5 bar, B-A 6.0 barPilot line body: Internal from B (A-X closed / B-Y orifice 1.2)
026-99697-H
Backordered
6 kgCast IronSubplateNBRSolenoidCheck Valve600 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CHydraulic Oil According to DIN 51524Position Control and Vent Function Solenoid activated, unpressurized circulation, without manual override, with amplifier.UnrestrictedNBRNG32 / ISO 6264Position control and vent function: Solenoid activated, unpressurized circulation, without manual override, with amplifierPilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openCover for end position controlPoppet with safety spoolAA=0.60 AC, AB=0.40 AC24 (VDC)A-B 2.2 bar, B-A 3.8 barPilot line body: Internal from A (A-X orifice 1.2 / B-Y open)
026-99808-0
Backordered
4.5 kgCast IronSubplateNBRSolenoidCheck Valve360 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CHydraulic Oil According to DIN 51524n/aUnrestrictedNBRNG25 / ISO 6264N/APilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACnaA-B 0.5 barPilot line body: External from X (A-X closed / B-Y closed)
056-40120-0
Backordered
4.5 kgCast IronSubplateNBRSolenoidCheck Valve360 L/minIndustrial Systems Division Europe350 bar60 °C-20 °CHydraulic Oil According to DIN 51524n/aUnrestrictedNBRNG25 / ISO 6264N/APilot line cap: Standard, pilot oil = pilot drain, X closed, Y open, Z orifice 1.2, X-Y open, Y1 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACnaA-B 1 bar, B-A 1.7 barPilot line body: Internal from B (A-X closed / B-Y orifice 1.2)