• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Body Material
  • Division
  • For Fluid Type
  • Function
  • Maximum Flow Rate
  • Maximum Operating Pressure
  • Maximum Operating Temperature
  • Minimum Operating Temperature
  • Mounting Position
More Filters...

2/2-Way Seat Valve for Subplate Mounting - Series D4S

Picture for category 2/2-Way Seat Valve for Subplate Mounting - Series D4S

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker's highly versatile 2/2-way seat valves series D4S for subplate mounting are designed for directional control functions and feature numerous options. A large variety of poppets, springs and covers – including shuttle valves, stroke limiters, solenoid valves (VV01) and position control – allows to design individual hydraulic solutions for nominal flow up to 600 l/min.

Markets:
• Industrial

Features/Benefits:
• Proven, robust design - ensures reliable operation
• Individual configurability, various function options - useable for numerous applications
• Good price-performance ratio - fast return of investment
• Short delivery time - no warehousing necessary
• Subplate mounting according to ISO 5781
• Leak-free seat valve design
• Numerous pilot options
• 6 poppet types:
    - D4S03 - NG10
    - D4S06 - NG25
    - D4S10 - NG32

Applications:
• Suitable for general hydraulic applications
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPartner AvailablePriceDivisionWeightBody MaterialMounting TypeSeal MaterialActuation TypeFor Fluid TypeProduct SeriesMaximum Flow RateMaximum Operating PressureMaximum Operating TemperatureMinimum Operating TemperatureFunctionMounting PositionSeal MaterialPort ConnectionSwitching OptionInput VoltagePilot Inlet / Drain LocationsCoverOptionsSpool TypeSleeve TypeMinimum Opening Pressure
056-40223-H
Backordered
Industrial Systems Division Europe2.7 kgCast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve180 L/min350 bar60 °C-20 °CVent Function Solenoid not activated, unpressurized circulation, with manual override.UnrestrictedNBRNG10 / ISO 6264Vent function: Solenoid not activated, unpressurized circulation, with manual override24 (VDC)Pilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)Pilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 1.0 BAR, B-A 1.5 BAR
056-40370-H
Backordered
Industrial Systems Division Europe4.5 kgCast IronSubplateFPMSolenoidWater-GlycolCheck Valve360 L/min350 bar60 °C-20 °CVent Function Solenoid activated, unpressurized circulation, with manual override.UnrestrictedFPMNG25 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual overridenaPilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)Pilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 0.6 BAR, B-A 1.0 BAR
056-40431-B
Backordered
Industrial Systems Division Europe4.5 kgCast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve360 L/min350 bar60 °C-20 °CVent Function Solenoid activated, unpressurized circulation, with manual override.UnrestrictedNBRNG25 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual override110/120 (VAC), 50/60 (Hz)Pilot line body: External from X (A-X closed / B-Y closed)Pilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 3.5 bar, B-A 6.0 bar
056-40569-H
Backordered
Industrial Systems Division Europe6 kgCast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve600 L/min350 bar60 °C-20 °CPosition ControlUnrestrictedNBRNG32 / ISO 6264Shuttle valve X-Y, position control and vent function: Solenoid not activated, unpressurized circulation, without manual override, with amplifier24 (VDC)Pilot line body: Internal from B (A-X closed / B-Y orifice 1.2)Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with safety spoolAA=0.60 AC, AB=0.40 ACA-B 3.5 bar, B-A 6.0 bar
056-40645-0
Backordered
Industrial Systems Division Europe2.7 kgCast IronSubplateNBRSolenoidHydraulic Oil According to DIN 51524Check Valve180 L/min350 bar60 °C-20 °Cn/aUnrestrictedNBRNG10 / ISO 6264N/AnaPilot line body: External from X (A-X closed / B-Y open)Pilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 0.6 bar, B-A 0.9 bar
D4S03-91114409G0QB1
Backordered
Industrial Systems Division Europe2.7 kgCast IronSubplateNBRSolenoidHydraulic Oil According to DIN 51524Check Valve180 L/min350 bar60 °C-20 °CVent Function Solenoid not activated, unpressurized circulation, with manual override.UnrestrictedNBRNG10 / ISO 6264Vent function: Solenoid not activated, unpressurized circulation, with manual override24 (VDC)Pilot line body: Internal from A (A-X orifice 1.2 / B-Y open)Pilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACA-B 2.2 bar
D4S03-91614109G0QB1
Backordered
Industrial Systems Division Europe2.7 kgCast IronSubplateNBRSolenoidHydraulic Oil According to DIN 51524Check Valve180 L/min350 bar60 °C-20 °CVent Function Solenoid not activated, unpressurized circulation, with manual override.UnrestrictedNBRNG10 / ISO 6264Vent function: Solenoid not activated, unpressurized circulation, with manual override24 (VDC)Pilot line body: Internal from A (A-X orifice 1.2 / B-Y open)Pilot line cap: With vent function, internal pilot drain, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACA-B 2.8 BAR
D4S03-921114B1
Backordered
Industrial Systems Division Europe2.7 kgCast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve180 L/min350 bar60 °C-20 °Cn/aUnrestrictedNBRNG10 / ISO 6264N/AnaPilot line body: External from X (A-X closed / B-Y open)Pilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedN/APoppet with closed bottom, 15° chamferAA=0.95 AC, AB=0.05 ACA-B 2.2 bar
D4S03-921144B1
Backordered
Industrial Systems Division Europe2.7 kgCast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve180 L/min350 bar60 °C-20 °Cn/aUnrestrictedNBRNG10 / ISO 6264N/AnaPilot line body: External from X (A-X closed / B-Y open)Pilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACA-B 2.2 bar
D4S03-921342B1
Backordered
Industrial Systems Division Europe2.7 kgCast IronSubplateNBRSolenoidHydraulic Oil According to DIN 51524Check Valve180 L/min350 bar60 °C-20 °Cn/aUnrestrictedNBRNG10 / ISO 6264N/AnaPilot line body: External from X (A-X closed / B-Y open)Pilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 1.0 BAR, B-A 1.5 BAR
D4S03-921342B5
Backordered
Industrial Systems Division Europe2.7 kgCast IronSubplateFPMPilotWater-GlycolCheck Valve180 L/min350 bar60 °C-20 °Cn/aUnrestrictedFPMNG10 / ISO 6264N/AnaPilot line body: External from X (A-X closed / B-Y open)Pilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 1.0 BAR, B-A 1.5 BAR
D4S03-921346B1
Backordered
Industrial Systems Division Europe2.7 kgCast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve180 L/min350 bar60 °C-20 °Cn/aUnrestrictedNBRNG10 / ISO 6264N/AnaPilot line body: External from X (A-X closed / B-Y open)Pilot line cap: Standard, pilot oil = pilot drain, X open, Y closed, Z orifice 1.2, X-Y open, Y1 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 2.0 bar, A-B 3.0 bar
D4S03-92211411G0QB1
Backordered
Industrial Systems Division Europe2.7 kgCast IronSubplateNBRSolenoidHydraulic Oil According to DIN 51524Check Valve180 L/min350 bar60 °C-20 °CVent Function Solenoid activated, unpressurized circulation, with manual override.UnrestrictedNBRNG10 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual override24 (VDC)Pilot line body: External from X (A-X closed / B-Y open)Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 15° chamferAA=0.95 AC, AB=0.05 ACA-B 2.2 bar
D4S03-9A211409G0QB1
Backordered
Hydraulic Valve Systems Division Europe2.7 kgCast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve180 L/min350 bar60 °C-20 °CVent Function Solenoid not activated, unpressurized circulation, with manual override.UnrestrictedNBRNG10 / ISO 6264Vent function: Solenoid not activated, unpressurized circulation, with manual override24 (VDC)Pilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closednaPoppet with closed bottom, 15° chamferAA=0.95 AC, AB=0.05 ACA-B 2.2 bar
D4S03-9A211411G0QB1
Backordered
Industrial Systems Division Europe2.7 kgCast IronSubplateNBRSolenoidHydraulic Oil According to DIN 51524Check Valve180 L/min350 bar60 °C-20 °CVent Function Solenoid activated, unpressurized circulation, with manual override.UnrestrictedNBRNG10 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual override24 (VDC)Pilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 15° chamferAA=0.95 AC, AB=0.05 ACA-B 2.2 bar
D4S03-9A214411W31B1
Backordered
Industrial Systems Division Europe2.7 kgCast IronSubplateNBRSolenoidHydraulic Oil According to DIN 51524Check Valve180 L/min350 bar60 °C-20 °CVent Function Solenoid activated, unpressurized circulation, with manual override.UnrestrictedNBRNG10 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual override230/240 (VAC), 50/60 (Hz)Pilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACA-B 2.2 bar
D4S03-9A234209G0QB1
Backordered
Industrial Systems Division Europe2.7 kgCast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve180 L/min350 bar60 °C-20 °CVent Function Solenoid not activated, unpressurized circulation, with manual override.UnrestrictedNBRNG10 / ISO 6264Vent function: Solenoid not activated, unpressurized circulation, with manual override24 (VDC)Pilot line body: Internal from A (A-X orifice 1.2 / B-Y closed)Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 1.0 BAR, B-A 1.5 BAR
D4S03-9B534311G0QB1
Backordered
Industrial Systems Division Europe2.7 kgCast IronSubplateNBRSolenoidHydraulic Oil According to DIN 51524Check Valve180 L/min350 bar60 °C-20 °CVent Function Solenoid activated, unpressurized circulation, with manual override.UnrestrictedNBRNG10 / ISO 6264Vent function: solenoid activated, unpressurized circulation, with manual override24 (VDC)Pilot line body: External from X (A-X closed / B-Y closed)Pilot line cap: With vent function, external to subplate, X open, Y open, Z orifice 1.2, X-Y closed, Y1 closed, VV01 openN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 0.6 bar, B-A 0.9 bar
D4S03-9C2141CDW31B1
Backordered
Industrial Systems Division Europe2.7 kgCast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve180 L/min350 bar60 °C-20 °CVent Function Solenoid activated, unpressurized circulation, with manual override.UnrestrictedNBRNG10 / ISO 6264Shuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual override230/240 (VAC), 50/60 (Hz)Pilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.95 AC, AB=0.05 ACA-B 2.8 BAR
D4S03-9C2344CDG0QB1
Backordered
Industrial Systems Division Europe2.7 kgCast IronSubplateNBRPilotHydraulic Oil According to DIN 51524Check Valve180 L/min350 bar60 °C-20 °CVent Function Solenoid activated, unpressurized circulation, with manual override.UnrestrictedNBRNG10 / ISO 6264Shuttle valve X-Y and vent function: Solenoid activated, unpressurized circulation, with manual override24 (VDC)Pilot line body: Internal from A+B (A-X orifice 1.2 / B-Y orifice 1.2)Pilot line cap: With vent function, external pilot drain from cap, X open, Y open, Z orifice 1.2, X-Y closed, Y1 open, VV01 closedN/APoppet with closed bottom, 45° chamferAA=0.60 AC, AB=0.40 ACA-B 4.0 bar, B-A 5.5 bar