• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Body Material
  • Cavity Size
  • Coil Nut Tightening Torque
  • Coil Type
  • Configuration
  • Current
  • Division
  • Division
  • Filter Efficiency Rating
More Filters...

Pressure Reducing Proportional Valves

Picture for category Pressure Reducing Proportional Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s family of proportional pressure reducing valves give the operator reliable performance for applications that require pressure limitation. These valves are capable of handling flows up to 37 lpm (10 gpm) and pressures as high as 210 bar (3000 psi). Parker’s proportional pressure reducing valves are ideal for pilot control or functions such as cylinders where there may be a risk of buckling due to over-pressurization, and can be paired with any Current Controlled Pulse Width Modulation (PWM) valve driver. The simple and compact design enables these valves to be used on a variety of equipment within the mobile, industrial, or manufacturing markets.

Markets:
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile

Features/Benefits:
• Low hysteresis
• One piece cartridge housing
• Non-magnetic spool and housing assembly

Applications:
• Pilot control
• Applications sensitive to over-pressurization

Additional Technical Insight:
Recommended to be used with a Current Controlled Pulse Width Modulation (PWM) valve driver.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPartner AvailablePriceMaximum Operating PressureSeal MaterialBody MaterialDivisionMinimum Operating TemperatureMaximum Kinematic ViscosityDivisionOverride FunctionalityWire Mesh Screen IncludedMaximum Inlet Pressure RatingFlow RateActuation TypeOperation TypeCavity SizeConfigurationFor Fluid TypeMaximum Operating TemperatureHysteresisValve MaterialOperating TemperatureFilter Efficiency RatingMounting TypeWeightCoil TypeInstallation TorqueMaximum Tank PressureCurrentFunctionFrequencyLeak RateResponse TimeFlow DirectionMaximum Flow RatePower ConsumptionMaximum Drain Flow RateMaximum Pressure SettingCoil Nut Tightening TorqueMaximum Regulating PressureOverride FunctionalitySeal MaterialMaximum Inlet Pressure RatingConfigurationMaximum Flow RateWire Mesh Screen IncludedMaximum Regulating Pressure
EPR111C10V
Backordered
350 barFluorocarbonn/aHydraulic Cartridge Systems Division-26 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems Divisionn/an/a350 bar10 Gal/minElectricalSolenoid OperatedC10-3LPressure Reducing/RelievingMineral-based or synthetic hydraulic fluids+204 °C4%All parts steel. All operating parts hardened steel-26 to +204 °CISO 4406 18/16/13, SAE Class 4Screw in cartridge valve0.59 kg1/2" Super Coil Low Watt (CCS)37-41 lb-ftN/A psi0.9 at 12VDC, 0.45 at 24VDC AProportional Pressure Reducing200-600 Hz492 @ 300 PSI (21 BAR), 946 @ 3000 PSI (210 BAR) cm3/minN/A msInlet port 1, Reducing port 2, Tank port 337.5 L/min9 @ Max Reduced Pressure WN/A cm3/minN/A psi7-9.5 Nm68.9 barN/AFluorocarbon5000 PSI, 350 BARPressure Reducing/Relieving10 GAL/MIN, 37.5 L/MINN/A1000 PSI, 68.9 BAR
EPR111C20
Backordered
350 barD-Ring (Standard)n/aHydraulic Cartridge Systems Division-35 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems Divisionn/an/a5000 psi37.5 L/minElectricalSolenoid OperatedC10-3LPressure Reducing/RelievingMineral-based or synthetic hydraulic fluids+93 °C4%All parts steel. All operating parts hardened steel-37 to +93 °CISO 4406 18/16/13, SAE Class 4Screw in cartridge valve0.59 kg1/2" Super Coil Low Watt (CCS)37-41 lb-ftN/A psi0.9 at 12VDC, 0.45 at 24VDC AProportional Pressure Reducing200-600 Hz492 @ 300 PSI (21 BAR), 946 @ 3000 PSI (210 BAR) cm3/minN/A msInlet port 1, Reducing port 2, Tank port 337.5 L/min9 @ Max Reduced Pressure WN/A cm3/minN/A psi7-9.5 Nm138 barN/AD-Ring (Standard)5000 PSI, 350 BARPressure Reducing/Relieving10 GAL/MIN, 37.5 L/MINN/A2000 PSI, 138 BAR
EPR111C20N
Backordered
350 barNitrilen/aHydraulic Cartridge Systems Division-30 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems Divisionn/an/a5000 psi10 Gal/minElectricalSolenoid OperatedC10-3LPressure Reducing/RelievingMineral-based or synthetic hydraulic fluids+121 °C4%All parts steel. All operating parts hardened steel-30 to +250 °FISO 4406 18/16/13, SAE Class 4Screw in cartridge valve1.3 lb1/2" Super Coil Low Watt (CCS)37-41 lb-ftN/A psi0.9 at 12VDC, 0.45 at 24VDC AProportional Pressure Reducing200-600 Hz492 @ 300 PSI (21 BAR), 946 @ 3000 PSI (210 BAR) cm3/minN/A msInlet port 1, Reducing port 2, Tank port 337.5 L/min9 @ Max Reduced Pressure WN/A cm3/minN/A psi5-7 lb-ft138 barN/ANitrile5000 PSI, 350 BARPressure Reducing/Relieving10 GAL/MIN, 37.5 L/MINN/A2000 PSI, 138 BAR
EPR111C20V
Backordered
350 barFluorocarbonn/aHydraulic Cartridge Systems Division-26 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems Divisionn/an/a350 bar37.5 L/minElectricalSolenoid OperatedC10-3LPressure Reducing/RelievingMineral-based or synthetic hydraulic fluids+204 °C4%All parts steel. All operating parts hardened steel-26 to +204 °CISO 4406 18/16/13, SAE Class 4Screw in cartridge valve0.59 kg1/2" Super Coil Low Watt (CCS)50-56 NmN/A psi0.9 at 12VDC, 0.45 at 24VDC AProportional Pressure Reducing200-600 Hz492 @ 300 PSI (21 BAR), 946 @ 3000 PSI (210 BAR) cm3/minN/A msInlet port 1, Reducing port 2, Tank port 337.5 L/min9 @ Max Reduced Pressure WN/A cm3/minN/A psi5-7 lb-ft138 barN/AFluorocarbon5000 PSI, 350 BARPressure Reducing/Relieving10 GAL/MIN, 37.5 L/MINN/A2000 PSI, 138 BAR
EPR111C30
Backordered
350 barD-Ring (Standard)n/aHydraulic Cartridge Systems Division-37 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems Divisionn/an/a350 bar10 Gal/minElectricalSolenoid OperatedC10-3LPressure Reducing/RelievingMineral-based or synthetic hydraulic fluids+200 °F4%All parts steel. All operating parts hardened steel-35 to +200 °FISO 4406 18/16/13, SAE Class 4Screw in cartridge valve0.59 kg1/2" Super Coil Low Watt (CCS)37-41 lb-ftN/A psi0.9 at 12VDC, 0.45 at 24VDC AProportional Pressure Reducing200-600 Hz492 @ 300 PSI (21 BAR), 946 @ 3000 PSI (210 BAR) cm3/minN/A msInlet port 1, Reducing port 2, Tank port 310 Gal/min9 @ Max Reduced Pressure WN/A cm3/minN/A psi5-7 lb-ft3000 psiN/AD-Ring (Standard)5000 PSI, 350 BARPressure Reducing/Relieving10 GAL/MIN, 37.5 L/MINN/A3000 PSI, 210 BAR
EPR111C30N
Backordered
350 barNitrilen/aHydraulic Cartridge Systems Division-30 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems Divisionn/an/a350 bar10 Gal/minElectricalSolenoid OperatedC10-3LPressure Reducing/RelievingMineral-based or synthetic hydraulic fluids+250 °F4%All parts steel. All operating parts hardened steel-34 to +121 °CISO 4406 18/16/13, SAE Class 4Screw in cartridge valve0.59 kg1/2" Super Coil Low Watt (CCS)50-56 NmN/A psi0.9 at 12VDC, 0.45 at 24VDC AProportional Pressure Reducing200-600 Hz492 @ 300 PSI (21 BAR), 946 @ 3000 PSI (210 BAR) cm3/minN/A msInlet port 1, Reducing port 2, Tank port 337.5 L/min9 @ Max Reduced Pressure WN/A cm3/minN/A psi5-7 lb-ft210 barN/ANitrile5000 PSI, 350 BARPressure Reducing/Relieving10 GAL/MIN, 37.5 L/MINN/A3000 PSI, 210 BAR
EPR111C30V
Backordered
350 barFluorocarbonn/aHydraulic Cartridge Systems Division-15 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems Divisionn/an/a350 bar10 Gal/minElectricalSolenoid OperatedC10-3LPressure Reducing/RelievingMineral-based or synthetic hydraulic fluids+400 °F4%All parts steel. All operating parts hardened steel-26 to +204 °CISO 4406 18/16/13, SAE Class 4Screw in cartridge valve0.59 kg1/2" Super Coil Low Watt (CCS)37-41 lb-ftN/A psi0.9 at 12VDC, 0.45 at 24VDC AProportional Pressure Reducing200-600 Hz492 @ 300 PSI (21 BAR), 946 @ 3000 PSI (210 BAR) cm3/minN/A msInlet port 1, Reducing port 2, Tank port 310 Gal/min9 @ Max Reduced Pressure WN/A cm3/minN/A psi5-7 lb-ft3000 psiN/AFluorocarbon5000 PSI, 350 BARPressure Reducing/Relieving10 GAL/MIN, 37.5 L/MINN/A3000 PSI, 210 BAR
EPR111C40
Backordered
350 barD-Ring (Standard)n/aHydraulic Cartridge Systems Division-37 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems Divisionn/an/a350 bar10 Gal/minElectricalSolenoid OperatedC10-3LPressure Reducing/RelievingMineral-based or synthetic hydraulic fluids+200 °F4%All parts steel. All operating parts hardened steel-35 to +200 °FISO 4406 18/16/13, SAE Class 4Screw in cartridge valve0.59 kg1/2" Super Coil Low Watt (CCS)50-56 NmN/A psi0.9 at 12VDC, 0.45 at 24VDC AProportional Pressure Reducing200-600 Hz492 @ 300 PSI (21 BAR), 946 @ 3000 PSI (210 BAR) cm3/minN/A msInlet port 1, Reducing port 2, Tank port 310 Gal/min9 @ Max Reduced Pressure WN/A cm3/minN/A psi5-7 lb-ft276 barN/AD-Ring (Standard)5000 PSI, 350 BARPressure Reducing/Relieving10 GAL/MIN, 37.5 L/MINN/A4000 PSI, 276 BAR
EPR111C40N
Backordered
5000 psiNitrilen/aHydraulic Cartridge Systems Division-34 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems Divisionn/an/a350 bar37.5 L/minElectricalSolenoid OperatedC10-3LPressure Reducing/RelievingMineral-based or synthetic hydraulic fluids+250 °F4%All parts steel. All operating parts hardened steel-34 to +121 °CISO 4406 18/16/13, SAE Class 4Screw in cartridge valve1.3 lb1/2" Super Coil Low Watt (CCS)50-56 NmN/A psi0.9 at 12VDC, 0.45 at 24VDC AProportional Pressure Reducing200-600 Hz492 @ 300 PSI (21 BAR), 946 @ 3000 PSI (210 BAR) cm3/minN/A msInlet port 1, Reducing port 2, Tank port 310 Gal/min9 @ Max Reduced Pressure WN/A cm3/minN/A psi5-7 lb-ft276 barN/ANitrile5000 PSI, 350 BARPressure Reducing/Relieving10 GAL/MIN, 37.5 L/MINN/A4000 PSI, 276 BAR
EPR111C40V
Backordered
5000 psiFluorocarbonn/aHydraulic Cartridge Systems Division-15 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems Divisionn/an/a5000 psi37.5 L/minElectricalSolenoid OperatedC10-3LPressure Reducing/RelievingMineral-based or synthetic hydraulic fluids+400 °F4%All parts steel. All operating parts hardened steel-26 to +204 °CISO 4406 18/16/13, SAE Class 4Screw in cartridge valve1.3 lb1/2" Super Coil Low Watt (CCS)37-41 lb-ftN/A psi0.9 at 12VDC, 0.45 at 24VDC AProportional Pressure Reducing200-600 Hz492 @ 300 PSI (21 BAR), 946 @ 3000 PSI (210 BAR) cm3/minN/A msInlet port 1, Reducing port 2, Tank port 337.5 L/min9 @ Max Reduced Pressure WN/A cm3/minN/A psi7-9.5 Nm276 barN/AFluorocarbon5000 PSI, 350 BARPressure Reducing/Relieving10 GAL/MIN, 37.5 L/MINN/A4000 PSI, 276 BAR
GP0130FN
Backordered
210 barNitrilen/aHydraulic Cartridge Systems Division-30 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems Divisionn/aYes3000 psi0.5 Gal/minElectricalSolenoid Operated54-1Bottom Cylinder PortMineral-based or synthetic hydraulic fluids+250 °F2%All parts steel. All operating parts hardened steel-30 to +250 °FISO 4406 18/16/13, SAE Class 4Screw in cartridge valve0.08 kg1/2" Super Coil High Watt (CCP), 1/2" Super Coil Low Watt (CCS)27 Nm440 psi1.1 at 12VDC (Low watt), 1.4 at 12VDC (High watt), 0.6 at 24VDC (Low watt), 0.7 at 24VDC (High watt) AProportional Pressure Reducing100-400 HzN/A cm3/min10 (Off), 30 (On) msInlet port 2, Reducing port 1, Tank port 31.9 L/min14, 19 W5 De-Energized, 200 In Regulating Zone @ 1000 PSI (68 BAR) cm3/minN/A psiFinger Tight Nm17 (Low Watt), 22 (High Watt) barN/ANitrile3000 PSI, 210 BARBottom Cylinder Port0.5 GAL/MIN, 1.9 L/MINYes250 PSI, 17 BAR Standard, or 320 PSI, 22 BAR High Pressure
GTP02340551V
Backordered
3000 psiFluorocarbonn/aHydraulic Cartridge Systems Division-26 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionInfinite ControlYes3000 psi19 L/minElectrical, ManualSolenoid operated, Manually operatedC08-3Side Cylinder PortMineral-based or synthetic hydraulic fluids+400 °F3.5%All parts steel. All operating parts hardened steel-26 to +204 °CISO 4406 18/16/13, SAE Class 4Screw in cartridge valve0.08 kg1/2" Super Coil High Watt (CCP)20 lb-ftN/A psi1.4 at 12VDC (High watt), 0.7 at 24VDC (High watt) AProportional Pressure Reducing100-400 HzN/A cm3/min10 msInlet port 3, Reducing port 2, Tank port 15 Gal/min19 W100 De-Energized, 750 In Regulating Zone @ 300 PSI (21 BAR) cm3/minN/A psi3 lb-ft31-40 barInfinite ControlFluorocarbon3000 PSI, 210 BARSide Cylinder Port5 GAL/MIN, 19 L/MINYes450-580 PSI, 31-40 BAR
GTP02340951V
Backordered
3000 psiFluorocarbonn/aHydraulic Cartridge Systems Division-26 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionInfinite ControlYes210 bar19 L/minElectrical, ManualSolenoid operated, Manually operatedC08-3Side Cylinder PortMineral-based or synthetic hydraulic fluids+400 °F3.5%All parts steel. All operating parts hardened steel-15 to +400 °FISO 4406 18/16/13, SAE Class 4Screw in cartridge valve0.08 kg1/2" Super Coil High Watt (CCP)20 lb-ftN/A psi1.4 at 12VDC (High watt), 0.7 at 24VDC (High watt) AProportional Pressure Reducing100-400 HzN/A cm3/min10 msInlet port 3, Reducing port 2, Tank port 15 Gal/min19 W100 De-Energized, 750 In Regulating Zone @ 300 PSI (21 BAR) cm3/minN/A psi4.1 Nm65-79 barInfinite ControlFluorocarbon3000 PSI, 210 BARSide Cylinder Port5 GAL/MIN, 19 L/MINYes940-1140 PSI, 65-79 BAR
GTP04340251N
Backordered
210 barNitrilen/aHydraulic Cartridge Systems Division-30 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionInfinite ControlYes210 bar30 L/minElectrical, ManualSolenoid operated, Manually operated3XSide Cylinder PortMineral-based or synthetic hydraulic fluids+250 °F3.5%All parts steel. All operating parts hardened steel-34 to +121 °CISO 4406 18/16/13, SAE Class 4Screw in cartridge valve0.13 kg5/8" Super Coil High Watt (CAP)30 NmN/A psi1.4 at 12VDC (High watt), 0.7 at 24VDC (High watt) AProportional Pressure Reducing100-400 HzN/A cm3/min40 msInlet port 3, Reducing port 2, Tank port 18 Gal/min28 W25 De-Energized, 800 In Regulating Zone @ 300 PSI (21 BAR) cm3/minN/A psi4.1 Nm200-240 psiInfinite ControlNitrile3000 PSI, 210 BARSide Cylinder Port8 GAL/MIN, 30 L/MINYes200-240 PSI, 14-17 BAR
GTP04340551V
Backordered
210 barFluorocarbonn/aHydraulic Cartridge Systems Division-26 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionInfinite ControlYes210 bar30 L/minElectrical, ManualSolenoid operated, Manually operated3XSide Cylinder PortMineral-based or synthetic hydraulic fluids+400 °F3.5%All parts steel. All operating parts hardened steel-15 to +400 °FISO 4406 18/16/13, SAE Class 4Screw in cartridge valve0.13 kg5/8" Super Coil High Watt (CAP)30 NmN/A psi1.4 at 12VDC (High watt), 0.7 at 24VDC (High watt) AProportional Pressure Reducing100-400 HzN/A cm3/min40 msInlet port 3, Reducing port 2, Tank port 130 L/min28 W25 De-Energized, 800 In Regulating Zone @ 300 PSI (21 BAR) cm3/minN/A psi3 lb-ft420-550 psiInfinite ControlFluorocarbon3000 PSI, 210 BARSide Cylinder Port8 GAL/MIN, 30 L/MINYes420-550 PSI, 29-38 BAR