Parker’s 2-way poppet style solenoid valves feature a proven design that ensures very low leakage when flow is blocked in one direction and minimized pressure drop in the free flow position. These valves can operate with hydraulic system flows as high as 260 lpm and pressures up to 350 bar with normally-open or normally closed configurations available. Parker’s 2-way poppet solenoid valves are ideal for unloading and load holding applications that require low poppet style leakage within mobile, industrial, or manufacturing markets._x000D_
_x000D_
Markets:_x000D_
• Aerial_x000D_
• Construction_x000D_
• Material Handling_x000D_
• Miscellaneous Industrial_x000D_
• Miscellaneous Manufacturing_x000D_
• Miscellaneous Mobile_x000D_
_x000D_
Features & Benefits:_x000D_
• Replaceable one-piece coils with low amp draw_x000D_
• Fast response available_x000D_
• Manual override options_x000D_
• Low leakage spherical poppet_x000D_
• All external parts zinc plated_x000D_
_x000D_
Applications:_x000D_
• Unloading circuits_x000D_
• Load holding applications_x000D_
• Lift circuits_x000D_
_x000D_
Additional Technical Insight:_x000D_
Parker’s 2 way poppet valves are pilot operated, low leakage solenoid actuated valves. Similar to a check valve, these valves will block flow in one direction will very low leakage (5 drops per minute, or less). When actuated, these valves allow flow to pass through the valve. These valves are typically selected due to their low leakage characteristics and their ability to meet higher flow requirements. Poppet valves are often used on single operation actuators or in unloading functions. They are available in normally closed and normally open types with fast response versions available._x000D_
_x000D_
Parker’s two way, two position poppet valves consist of a main poppet, a pilot piston, a spring, and a solenoid coil. _x000D_
_x000D_
The normally closed poppet version of these valves will act as a check valve when the valve is de-energized. This blocks flow in both directions while allowing free flow in the reverse direction. When the coil is energized, the poppet is piloted open (lifts) and allows free flow in the previously checked direction, typically from the side of the cartridge out the nose._x000D_
_x000D_
The normally open poppet version of these valves, when the coil is de-energized, will allow free flow from the side port of the valve (port 2) out the nose of the valve (port 1). Energizing the coil shifts the poppet to block flow in both directions._x000D_
_x000D_
Operation: The normally closed poppet valve is held on its seat by a spring, blocking the pilot flow. This will allow pressure at the inlet port (port 2) to hold the poppet on its seat preventing flow through the valve (port 2 to port 1)._x000D_
_x000D_
If the nose of the cartridge (port 1) is pressurized enough to overcome the spring force, and pushing the poppet off of its seat, flow will be allowed through port 1 to port 2. When the coil is energized, the pilot poppet is lifted off of its seat, venting the pressure inside the poppet to port 1. This creates a pressure imbalance across the main poppet, therefore lifting the poppet and allowing flow from the side to the nose (2 to 1). Because these valves are pilot operated, a minimal amount of pressure differential is necessary (25-50 psi), along with flow between ports 2 and 1 must be present to overcome the spring and lift the poppet._x000D_
_x000D_
The normally open valve pilot is held off its seat by spring force. Pilot flow is vented to port 1, creating a pressure imbalance that moves the main poppet. This differential lifts the poppet allowing flow from the side to nose (2 to 1). Since poppet valves are pilot operated, a minimum amount of pressure differential (25-50 psi) between ports 2 overcomes the spring force to drive the valve pilot and main poppet into their seats, thus blocking flow from port 2 to 1. If the nose of the cartridge (port 1) is pressurized, the pressure will overcome the spring force and solenoid force, pushing the poppet off of its seat, allowing restricted flow through the cartridge (1 to 2).
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPartner AvailablePriceFunctionSeal MaterialBody MaterialMaximum Operating PressureMinimum Operating TemperatureMaximum Kinematic ViscosityDivisionFlow DirectionOverride FunctionalityMaximum Flow RateFlow RateCavity SizeMaximum Inlet Pressure RatingActuation TypeOperation TypeWeightFor Fluid TypeMaximum Operating TemperatureConfigurationValve MaterialOperating TemperatureFilter Efficiency RatingWire Mesh Screen IncludedMounting TypeCoil TypeLeak RateInput VoltageResponse TimeInstallation TorqueCoil Nut Tightening TorqueAdjustment MechanismFree Reverse FlowSeal MaterialConfigurationFlow RateMaximum Inlet Pressure RatingActuation TypeWire Mesh Screen Included
DSH081NV
Backordered
Backordered
$100.75
2-wayFluorocarbonn/a5000 psi-26 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)n/a30 L/min30 L/minC08-25000 psiElectricalSolenoid Operated0.25 lbMineral-based or synthetic hydraulic fluids+400 °FNormally OpenAll parts steel. All operating parts hardened steel-26 to +204 °CISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms32-36 lb-ft5-7 lb-ftN/ANoFluorocarbonNormally Open8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARElectricalNo
DSH101C
Backordered
64 in stock
$72.50
2-wayD-Ring (Standard)n/a350 bar-37 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)n/a60 L/min60 L/minC10-25000 psiElectricalSolenoid Operated0.41 lbMineral-based or synthetic hydraulic fluids+200 °FNormally ClosedAll parts steel. All operating parts hardened steel-37 to +93 °CISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min80 ms51-55 lb-ft7-10 NmN/ANoD-Ring (Standard)Normally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARElectricalNo
DSH101CH
Backordered
Backordered
$111.50
2-wayD-Ring (Standard)n/a350 bar-37 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)n/a15 Gal/min60 L/minC10-2350 barElectricalSolenoid Operated0.2 kgMineral-based or synthetic hydraulic fluids+93 °CNormally ClosedAll parts steel. All operating parts hardened steel-35 to +200 °FISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms51-55 lb-ft7-10 NmN/ANoD-Ring (Standard)Normally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARElectricalNo
DSH101CHR
Backordered
4 in stock
$111.50
2-wayD-Ring (Standard)n/a350 bar-35 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)n/a15 Gal/min15 Gal/minC10-2350 barElectricalSolenoid Operated0.2 kgMineral-based or synthetic hydraulic fluids+93 °CNormally ClosedAll parts steel. All operating parts hardened steel-35 to +200 °FISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms69-75 Nm7-10 NmN/AYesD-Ring (Standard)Normally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARElectricalNo
DSH101CHRT
Backordered
Backordered
$156.00
2-wayD-Ring (Standard)n/a350 bar-35 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)Push and Twist15 Gal/min15 Gal/minC10-2350 barElectrical, ManualSolenoid operated, Manually operated0.2 kgMineral-based or synthetic hydraulic fluids+93 °CNormally ClosedAll parts steel. All operating parts hardened steel-35 to +200 °FISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms69-75 Nm7-10 NmN/AYesD-Ring (Standard)Normally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARElectrical, ManualNo
DSH101CHRTV
Backordered
2-wayFluorocarbonn/a5000 psi-15 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)Push and Twist15 Gal/min15 Gal/minC10-2350 barElectrical, ManualSolenoid operated, Manually operated0.41 lbMineral-based or synthetic hydraulic fluids+204 °CNormally ClosedAll parts steel. All operating parts hardened steel-15 to +400 °FISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms69-75 Nm5-7 lb-ftN/AYesFluorocarbonNormally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARElectrical, ManualNo
DSH101CHRV
Backordered
Backordered
$116.50
2-wayFluorocarbonn/a5000 psi-15 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)n/a60 L/min15 Gal/minC10-25000 psiElectricalSolenoid Operated0.2 kgMineral-based or synthetic hydraulic fluids+400 °FNormally ClosedAll parts steel. All operating parts hardened steel-15 to +400 °FISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms69-75 Nm5-7 lb-ftN/AYesFluorocarbonNormally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARElectricalNo
DSH101CHT
Backordered
Backordered
$156.00
2-wayD-Ring (Standard)n/a350 bar-35 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)Push and Twist15 Gal/min15 Gal/minC10-2350 barElectrical, ManualSolenoid operated, Manually operated0.2 kgMineral-based or synthetic hydraulic fluids+93 °CNormally ClosedAll parts steel. All operating parts hardened steel-35 to +200 °FISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms51-55 lb-ft7-10 NmN/ANoD-Ring (Standard)Normally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARElectrical, ManualNo
DSH101CHV
Backordered
Backordered
$116.50
2-wayFluorocarbonn/a350 bar-26 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)n/a60 L/min60 L/minC10-25000 psiElectricalSolenoid Operated0.2 kgMineral-based or synthetic hydraulic fluids+400 °FNormally ClosedAll parts steel. All operating parts hardened steel-15 to +400 °FISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms69-75 Nm7-10 NmN/ANoFluorocarbonNormally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARElectricalNo
DSH101CR
Backordered
61 in stock
$79.25
2-wayD-Ring (Standard)n/a350 bar-35 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)n/a15 Gal/min15 Gal/minC10-2350 barElectricalSolenoid Operated0.41 lbMineral-based or synthetic hydraulic fluids+93 °CNormally ClosedAll parts steel. All operating parts hardened steel-37 to +93 °CISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min80 ms51-55 lb-ft7-10 NmN/AYesD-Ring (Standard)Normally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARElectricalNo
DSH101CRT
Backordered
50 in stock
$123.50
2-wayD-Ring (Standard)n/a5000 psi-35 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)Push and Twist60 L/min15 Gal/minC10-2350 barElectrical, ManualSolenoid operated, Manually operated0.2 kgMineral-based or synthetic hydraulic fluids+93 °CNormally ClosedAll parts steel. All operating parts hardened steel-35 to +200 °FISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min80 ms69-75 Nm5-7 lb-ftN/AYesD-Ring (Standard)Normally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARElectrical, ManualNo
DSH101CRTS
Backordered
2-wayD-Ring (Standard)n/a5000 psi-37 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)Push and Twist60 L/min60 L/minC10-25000 psiElectrical, ManualSolenoid operated, Manually operated0.41 lbMineral-based or synthetic hydraulic fluids+93 °CNormally ClosedAll parts steel. All operating parts hardened steel-37 to +93 °CISO 4406 18/16/13, SAE Class 4YesScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min80 ms51-55 lb-ft5-7 lb-ftN/AYesD-Ring (Standard)Normally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARElectrical, ManualYes
DSH101CRTV
Backordered
Backordered
$128.25
2-wayFluorocarbonn/a5000 psi-15 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)Push and Twist15 Gal/min60 L/minC10-2350 barElectrical, ManualSolenoid operated, Manually operated0.41 lbMineral-based or synthetic hydraulic fluids+204 °CNormally ClosedAll parts steel. All operating parts hardened steel-26 to +204 °CISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min80 ms69-75 Nm5-7 lb-ftN/AYesFluorocarbonNormally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARElectrical, ManualNo
DSH101CRV
Backordered
Backordered
$84.25
2-wayFluorocarbonn/a5000 psi-26 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)n/a15 Gal/min60 L/minC10-2350 barElectricalSolenoid Operated0.41 lbMineral-based or synthetic hydraulic fluids+204 °CNormally ClosedAll parts steel. All operating parts hardened steel-15 to +400 °FISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min80 ms69-75 Nm7-10 NmN/AYesFluorocarbonNormally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARElectricalNo
DSH101CS
Backordered
Backordered
$79.50
2-wayD-Ring (Standard)n/a350 bar-35 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)n/a15 Gal/min15 Gal/minC10-25000 psiElectricalSolenoid Operated0.2 kgMineral-based or synthetic hydraulic fluids+200 °FNormally ClosedAll parts steel. All operating parts hardened steel-35 to +200 °FISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min80 ms69-75 Nm7-10 NmN/ANoD-Ring (Standard)Normally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARElectricalYes
DSH101CT
Backordered
38 in stock
$117.00
2-wayD-Ring (Standard)n/a5000 psi-37 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)Push and Twist60 L/min60 L/minC10-25000 psiElectrical, ManualSolenoid operated, Manually operated0.2 kgMineral-based or synthetic hydraulic fluids+200 °FNormally ClosedAll parts steel. All operating parts hardened steel-35 to +200 °FISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min80 ms69-75 Nm5-7 lb-ftN/ANoD-Ring (Standard)Normally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARElectrical, ManualNo
DSH101CTS
Backordered
2-wayD-Ring (Standard)n/a5000 psi-37 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)Push and Twist15 Gal/min60 L/minC10-2350 barElectrical, ManualSolenoid operated, Manually operated0.41 lbMineral-based or synthetic hydraulic fluids+200 °FNormally ClosedAll parts steel. All operating parts hardened steel-37 to +93 °CISO 4406 18/16/13, SAE Class 4YesScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min80 ms51-55 lb-ft5-7 lb-ftN/ANoD-Ring (Standard)Normally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARElectrical, ManualYes
DSH101CTV
Backordered
Backordered
$122.00
2-wayFluorocarbonn/a350 bar-26 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)Push and Twist15 Gal/min60 L/minC10-2350 barElectrical, ManualSolenoid operated, Manually operated0.41 lbMineral-based or synthetic hydraulic fluids+204 °CNormally ClosedAll parts steel. All operating parts hardened steel-15 to +400 °FISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min80 ms69-75 Nm7-10 NmN/ANoFluorocarbonNormally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARElectrical, ManualNo
DSH101CV
Backordered
Backordered
$77.25
2-wayFluorocarbonn/a350 bar-15 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)n/a15 Gal/min15 Gal/minC10-25000 psiElectricalSolenoid Operated0.2 kgMineral-based or synthetic hydraulic fluids+400 °FNormally ClosedAll parts steel. All operating parts hardened steel-15 to +400 °FISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min80 ms69-75 Nm7-10 NmN/ANoFluorocarbonNormally Closed15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARElectricalNo
DSH101N
Backordered
44 in stock
$106.50
2-wayD-Ring (Standard)n/a350 bar-37 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)n/a60 L/min15 Gal/minC10-25000 psiElectricalSolenoid Operated0.2 kgMineral-based or synthetic hydraulic fluids+200 °FNormally OpenAll parts steel. All operating parts hardened steel-35 to +200 °FISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve5/8" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min70 ms69-75 Nm7-10 NmN/ANoD-Ring (Standard)Normally Open15 GAL/MIN, 60 L/MIN5000 PSI, 350 BARElectricalNo