2 Way Poppet Type Solenoid Valve

Picture for category 2 Way Poppet Type Solenoid Valve

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s 2-way poppet style solenoid valves feature a proven design that ensures very low leakage when flow is blocked in one direction and minimized pressure drop in the free flow position. These valves can operate with hydraulic system flows as high as 260 lpm and pressures up to 350 bar with normally-open or normally closed configurations available. Parker’s 2-way poppet solenoid valves are ideal for unloading and load holding applications that require low poppet style leakage within mobile, industrial, or manufacturing markets._x000D_
_x000D_
Markets:_x000D_
• Aerial_x000D_
• Construction_x000D_
• Material Handling_x000D_
• Miscellaneous Industrial_x000D_
• Miscellaneous Manufacturing_x000D_
• Miscellaneous Mobile_x000D_
_x000D_
Features & Benefits:_x000D_
• Replaceable one-piece coils with low amp draw_x000D_
• Fast response available_x000D_
• Manual override options_x000D_
• Low leakage spherical poppet_x000D_
• All external parts zinc plated_x000D_
_x000D_
Applications:_x000D_
• Unloading circuits_x000D_
• Load holding applications_x000D_
• Lift circuits_x000D_
_x000D_
Additional Technical Insight:_x000D_
Parker’s 2 way poppet valves are pilot operated, low leakage solenoid actuated valves. Similar to a check valve, these valves will block flow in one direction will very low leakage (5 drops per minute, or less). When actuated, these valves allow flow to pass through the valve. These valves are typically selected due to their low leakage characteristics and their ability to meet higher flow requirements. Poppet valves are often used on single operation actuators or in unloading functions. They are available in normally closed and normally open types with fast response versions available._x000D_
_x000D_
Parker’s two way, two position poppet valves consist of a main poppet, a pilot piston, a spring, and a solenoid coil. _x000D_
_x000D_
The normally closed poppet version of these valves will act as a check valve when the valve is de-energized. This blocks flow in both directions while allowing free flow in the reverse direction. When the coil is energized, the poppet is piloted open (lifts) and allows free flow in the previously checked direction, typically from the side of the cartridge out the nose._x000D_
_x000D_
The normally open poppet version of these valves, when the coil is de-energized, will allow free flow from the side port of the valve (port 2) out the nose of the valve (port 1). Energizing the coil shifts the poppet to block flow in both directions._x000D_
_x000D_
Operation: The normally closed poppet valve is held on its seat by a spring, blocking the pilot flow. This will allow pressure at the inlet port (port 2) to hold the poppet on its seat preventing flow through the valve (port 2 to port 1)._x000D_
_x000D_
If the nose of the cartridge (port 1) is pressurized enough to overcome the spring force, and pushing the poppet off of its seat, flow will be allowed through port 1 to port 2. When the coil is energized, the pilot poppet is lifted off of its seat, venting the pressure inside the poppet to port 1. This creates a pressure imbalance across the main poppet, therefore lifting the poppet and allowing flow from the side to the nose (2 to 1). Because these valves are pilot operated, a minimal amount of pressure differential is necessary (25-50 psi), along with flow between ports 2 and 1 must be present to overcome the spring and lift the poppet._x000D_
_x000D_
The normally open valve pilot is held off its seat by spring force. Pilot flow is vented to port 1, creating a pressure imbalance that moves the main poppet. This differential lifts the poppet allowing flow from the side to nose (2 to 1). Since poppet valves are pilot operated, a minimum amount of pressure differential (25-50 psi) between ports 2 overcomes the spring force to drive the valve pilot and main poppet into their seats, thus blocking flow from port 2 to 1. If the nose of the cartridge (port 1) is pressurized, the pressure will overcome the spring force and solenoid force, pushing the poppet off of its seat, allowing restricted flow through the cartridge (1 to 2).
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPartner AvailablePriceFunctionBody MaterialMaximum Operating PressureMinimum Operating TemperatureMaximum Kinematic ViscosityDivisionFlow DirectionMaximum Operating TemperatureOverride FunctionalityMaximum Flow RateFlow RateCavity SizeMaximum Inlet Pressure RatingSeal MaterialActuation TypeOperation TypeWeightFor Fluid TypeConfigurationValve MaterialFilter Efficiency RatingWire Mesh Screen IncludedMounting TypeOperating TemperatureCoil TypeLeak RateInput VoltageResponse TimeInstallation TorqueCoil Nut Tightening TorqueAdjustment MechanismFree Reverse FlowConfigurationFlow RateMaximum Inlet Pressure RatingSeal MaterialActuation TypeWire Mesh Screen Included
DSH081C
Backordered
1 in stock
$68.50
2-wayn/a5000 psi-37 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)+200 °Fn/a30 L/min8 Gal/minC08-25000 psiD-Ring (Standard)ElectricalSolenoid Operated0.25 lbMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-37 to +93 °C1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms32-36 lb-ft5-7 lb-ftN/ANoNormally Closed8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARD-Ring (Standard)ElectricalNo
DSH081CH
Backordered
Backordered
$85.00
2-wayn/a5000 psi-35.0 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)+93 °Cn/a8 Gal/min8 Gal/minC08-2350 barD-Ring (Standard)ElectricalSolenoid Operated0.11 kgMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-35 to +200 °F1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min30 ms43-49 Nm5-7 lb-ftN/ANoNormally Closed8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARD-Ring (Standard)ElectricalNo
DSH081CHR
Backordered
2 in stock
$89.25
2-wayn/a350 bar-35.0 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)+93 °Cn/a8 Gal/min8 Gal/minC08-2350 barD-Ring (Standard)ElectricalSolenoid Operated0.11 kgMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-35 to +200 °F1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min30 ms43-49 Nm7-10 NmN/AYesNormally Closed8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARD-Ring (Standard)ElectricalNo
DSH081CHRT
Backordered
Backordered
$133.50
2-wayn/a350 bar-35.0 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)+93 °CPush and Twist8 Gal/min8 Gal/minC08-2350 barD-Ring (Standard)Electrical, ManualSolenoid operated, Manually operated0.11 kgMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-35 to +200 °F1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min30 ms43-49 Nm7-10 NmN/AYesNormally Closed8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARD-Ring (Standard)Electrical, ManualNo
DSH081CHRTV
Backordered
2-wayn/a5000 psi-26 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)+400 °FPush and Twist30 L/min30 L/minC08-25000 psiFluorocarbonElectrical, ManualSolenoid operated, Manually operated0.25 lbMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-26 to +204 °C1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min30 ms32-36 lb-ft5-7 lb-ftN/AYesNormally Closed8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARFluorocarbonElectrical, ManualNo
DSH081CHRV
Backordered
Backordered
$94.00
2-wayn/a5000 psi-15 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)+400 °Fn/a8 Gal/min8 Gal/minC08-25000 psiFluorocarbonElectricalSolenoid Operated0.25 lbMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-26 to +204 °C1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min30 ms32-36 lb-ft5-7 lb-ftN/AYesNormally Closed8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARFluorocarbonElectricalNo
DSH081CHS
Backordered
2-wayn/a350 bar-35.0 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)+93 °Cn/a8 Gal/min30 L/minC08-2350 barD-Ring (Standard)ElectricalSolenoid Operated0.25 lbMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4YesScrew in cartridge valve-35 to +200 °F1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min30 ms43-49 Nm7-10 NmN/ANoNormally Closed8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARD-Ring (Standard)ElectricalYes
DSH081CHT
Backordered
Backordered
$129.25
2-wayn/a350 bar-37 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)+93 °CPush and Twist30 L/min8 Gal/minC08-25000 psiD-Ring (Standard)Electrical, ManualSolenoid operated, Manually operated0.25 lbMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-37 to +93 °C1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min30 ms32-36 lb-ft7-10 NmN/ANoNormally Closed8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARD-Ring (Standard)Electrical, ManualNo
DSH081CHTV
Backordered
2-wayn/a350 bar-26 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)+400 °FPush and Twist30 L/min30 L/minC08-25000 psiFluorocarbonElectrical, ManualSolenoid operated, Manually operated0.11 kgMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-26 to +204 °C1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min30 ms32-36 lb-ft5-7 lb-ftN/ANoNormally Closed8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARFluorocarbonElectrical, ManualNo
DSH081CR
Backordered
10 in stock
$71.50
2-wayn/a350 bar-35.0 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)+93 °Cn/a30 L/min8 Gal/minC08-25000 psiD-Ring (Standard)ElectricalSolenoid Operated0.11 kgMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-35 to +200 °F1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms43-49 Nm7-10 NmN/AYesNormally Closed8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARD-Ring (Standard)ElectricalNo
DSH081CRS
Backordered
Backordered
$67.50
2-wayn/a5000 psi-37 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)+200 °Fn/a30 L/min30 L/minC08-25000 psiD-Ring (Standard)ElectricalSolenoid Operated0.25 lbMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4YesScrew in cartridge valve-35 to +200 °F1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms32-36 lb-ft5-7 lb-ftN/AYesNormally Closed8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARD-Ring (Standard)ElectricalYes
DSH081CRT
Backordered
9 in stock
$115.25
2-wayn/a5000 psi-35.0 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)+93 °CPush and Twist30 L/min8 Gal/minC08-2350 barD-Ring (Standard)Electrical, ManualSolenoid operated, Manually operated0.11 kgMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-35 to +200 °F1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms43-49 Nm5-7 lb-ftN/AYesNormally Closed8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARD-Ring (Standard)Electrical, ManualNo
DSH081CRTS
Backordered
Backordered
$122.50
2-wayn/a5000 psi-37 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)+93 °CPush and Twist30 L/min30 L/minC08-25000 psiD-Ring (Standard)Electrical, ManualSolenoid operated, Manually operated0.25 lbMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4YesScrew in cartridge valve-37 to +93 °C1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms32-36 lb-ft5-7 lb-ftN/AYesNormally Closed8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARD-Ring (Standard)Electrical, ManualYes
DSH081CRTV
Backordered
2-wayn/a350 bar-26 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)+204 °CPush and Twist8 Gal/min30 L/minC08-25000 psiFluorocarbonElectrical, ManualSolenoid operated, Manually operated0.25 lbMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-15 to +400 °F1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms32-36 lb-ft7-10 NmN/AYesNormally Closed8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARFluorocarbonElectrical, ManualNo
DSH081CRV
Backordered
Backordered
$76.00
2-wayn/a5000 psi-26 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)+400 °Fn/a30 L/min30 L/minC08-25000 psiFluorocarbonElectricalSolenoid Operated0.11 kgMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-26 to +204 °C1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms32-36 lb-ft5-7 lb-ftN/AYesNormally Closed8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARFluorocarbonElectricalNo
DSH081CS
Backordered
Backordered
$75.25
2-wayn/a350 bar-35 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)+93 °Cn/a30 L/min8 Gal/minC08-2350 barD-Ring (Standard)ElectricalSolenoid Operated0.25 lbMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4YesScrew in cartridge valve-37 to +93 °C1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms32-36 lb-ft7-10 NmN/ANoNormally Closed8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARD-Ring (Standard)ElectricalYes
DSH081CT
Backordered
Backordered
$113.00
2-wayn/a5000 psi-37 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)+93 °CPush and Twist8 Gal/min30 L/minC08-2350 barD-Ring (Standard)Electrical, ManualSolenoid operated, Manually operated0.25 lbMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-37 to +93 °C1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms32-36 lb-ft5-7 lb-ftN/ANoNormally Closed8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARD-Ring (Standard)Electrical, ManualNo
DSH081CTS
Backordered
2-wayn/a5000 psi-35 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)+93 °CPush and Twist8 Gal/min30 L/minC08-2350 barD-Ring (Standard)Electrical, ManualSolenoid operated, Manually operated0.25 lbMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4YesScrew in cartridge valve-37 to +93 °C1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms43-49 Nm5-7 lb-ftN/ANoNormally Closed8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARD-Ring (Standard)Electrical, ManualYes
DSH081CTV
Backordered
2-wayn/a5000 psi-15 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)+400 °FPush and Twist8 Gal/min30 L/minC08-25000 psiFluorocarbonElectrical, ManualSolenoid operated, Manually operated0.25 lbMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-26 to +204 °C1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms32-36 lb-ft5-7 lb-ftN/ANoNormally Closed8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARFluorocarbonElectrical, ManualNo
DSH081CV
Backordered
Backordered
$73.25
2-wayn/a350 bar-26 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionSide to Nose (2-1)+400 °Fn/a30 L/min30 L/minC08-25000 psiFluorocarbonElectricalSolenoid Operated0.11 kgMineral-based or synthetic hydraulic fluidsNormally ClosedAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4NoScrew in cartridge valve-26 to +204 °C1/2" Super Coil5 drops/min85% of rated voltage at 72°F (20°C) min50 ms43-49 Nm7-10 NmN/ANoNormally Closed8 GAL/MIN, 30 L/MIN5000 PSI, 350 BARFluorocarbonElectricalNo