• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Adjustment Mechanism
  • Body Material
  • Cavity Size
  • Configuration
  • Connection Size
  • Connection Type
  • Division
  • Division
  • Filter Efficiency Rating
More Filters...

Pressure Compensated Priority Flow Control Valves

Picture for category Pressure Compensated Priority Flow Control Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s family of pressure compensated priority flow control valves feature a proven design that allows for a reliable and repeatable flow compensation curve throughout a wide pressure range while ensuring priority flow is met. These valves can operate with hydraulic system flows as high as 90 lpm and pressures up to 420 bar with a selection of adjustment and tamper-proof options. Parker’s pressure compensated priority flow control valves are ideal for steering, brake, or actuator control applications within a broad range of markets, such as the agriculture, construction, material handling, industrial, and oil & gas markets.

Markets:
• Agriculture
• Construction Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Mobile
• Oil & Gas

Features/Benefits:
• Fine adjustments
• Reverse flow function
• Hardened working parts for maximum durability
• Tamperproof options available
• All external parts zinc plated

Applications:
• Steering applications
• Actuator speed control
• Meter-in circuits

Additional Technical Insight:
Priority style pressure compensator flow control valves maintain constant priority flow to one leg of a circuit regardless of any changes in load or inlet pressure. Once the priority flow is satisfied, any excess flow may be used in other parts of the circuit. The valve consists of a control orifice housed within a spring biased compensator spool. This orifice may be fixed or adjustable. The priority port is normally open while the bypass port is normally closed. As flow enters the inlet port of the cartridge, it passes through the control orifice. A pressure differential is created across the compensator spool. If the inlet flow exceeds the setting of the valve, the force produced by this pressure differential exceeds the spring force and shifts the compensator spool; opening up the bypass port, and bypassing the excess flow. If the load pressure at the bypass port is greater than the load pressure at the priority port, the compensator spool will further shift restricting the priority flow to that of the valve setting. However, caution should be taken if the priority gets blocked so that no flow can pass through the control orifice, the compensator spool will shift, blocking the bypass port and allowing inlet pressure to go to full system relief pressure. It is common to place an external relief valve downstream of the priority flow port to prevent a no flow condition.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPartner AvailablePriceDivisionMaximum Operating PressureBody MaterialMinimum Operating TemperatureOperating TemperatureMaximum Regulated Flow RateFlow RateSeal MaterialActuation TypeFunctionOperation TypeMaximum Kinematic ViscosityStandard Flow Rate SettingFilter Efficiency RatingInstallation TorqueAdjustment MechanismConfigurationMaximum Operating TemperatureFlow Rate Display RangeFlow Rate AccuracyCavity SizeConnection SizeMaximum Flow RateWeightMaximum Inlet Pressure RatingMaximum Priority FlowFor Fluid TypeConnection TypeDivisionValve MaterialFlow Rate Display RangeMaximum Flow RateAdjustment MechanismStandard Flow Rate SettingSeal Material
FP101K295V
Backordered
Hydraulic Cartridge Systems Division3500 psin/a-26 °C-15 to +400 °FN/A L/min56.3 L/minFluorocarbonPressure CompensatedFlow Regulator ValveManually operated45-2000 SSU (6 to 420 cSt)N/A L/minISO 4406 18/16/13, SAE Class 416 lb-ftKnobPriority Flow+400 °F2.3-3.6 Gal/min20%C10-3n/a15 Gal/min0.5 lb3500 psi9 Gal/minMineral-based or synthetic hydraulic fluidsn/aHydraulic Systems DivisionAll parts steel. All operating parts hardened steel2.3-3.6 GAL/MIN, 8.6-13.5 L/MIN15 GAL/MIN, 56.3 L/MINKnobN/AFluorocarbon
FP101K405
Backordered
Hydraulic Cartridge Systems Division3500 psin/a-34 °C-34 to +121 °CN/A L/min56.3 L/minNitrilePressure CompensatedFlow Regulator ValveManually operated45-2000 SSU (6 to 420 cSt)N/A L/minISO 4406 18/16/13, SAE Class 416 lb-ftKnobPriority Flow+121 °C3.1-5 Gal/min20%C10-3n/a56.3 L/min0.23 kg3500 psi33.8 L/minMineral-based or synthetic hydraulic fluidsn/aHydraulic Systems DivisionAll parts steel. All operating parts hardened steel3.1-5 GAL/MIN, 11.6-18.8 L/MIN15 GAL/MIN, 56.3 L/MINKnobN/ANitrile
FP101K405V
Backordered
Hydraulic Cartridge Systems Division3500 psin/a-15 °F-26 to +204 °CN/A L/min56.3 L/minFluorocarbonPressure CompensatedFlow Regulator ValveManually operated45-2000 SSU (6 to 420 cSt)N/A L/minISO 4406 18/16/13, SAE Class 422 NmKnobPriority Flow+204 °C3.1-5 Gal/min20%C10-3n/a56.3 L/min0.5 lb245 bar33.8 L/minMineral-based or synthetic hydraulic fluidsn/aHydraulic Systems DivisionAll parts steel. All operating parts hardened steel3.1-5 GAL/MIN, 11.6-18.8 L/MIN15 GAL/MIN, 56.3 L/MINKnobN/AFluorocarbon
FP101S405V
Backordered
Hydraulic Cartridge Systems Division245 barn/a-26 °C-26 to +204 °CN/A L/min56.3 L/minFluorocarbonPressure CompensatedFlow Regulator ValveManually operated45-2000 SSU (6 to 420 cSt)N/A L/minISO 4406 18/16/13, SAE Class 422 NmScrewPriority Flow+400 °F11.6-18.8 L/min20%C10-3n/a56.3 L/min0.23 kg245 bar9 Gal/minMineral-based or synthetic hydraulic fluidsn/aHydraulic Systems DivisionAll parts steel. All operating parts hardened steel3.1-5 GAL/MIN, 11.6-18.8 L/MIN15 GAL/MIN, 56.3 L/MINScrewN/AFluorocarbon
FP101S575V
Backordered
Hydraulic Cartridge Systems Division3500 psin/a-26 °C-15 to +400 °FN/A L/min15 Gal/minFluorocarbonPressure CompensatedFlow Regulator ValveManually operated45-2000 SSU (6 to 420 cSt)N/A L/minISO 4406 18/16/13, SAE Class 422 NmScrewPriority Flow+204 °C4.5-7 Gal/min20%C10-3n/a56.3 L/min0.5 lb245 bar9 Gal/minMineral-based or synthetic hydraulic fluidsn/aHydraulic Systems DivisionAll parts steel. All operating parts hardened steel4.5-7 GAL/MIN, 16.9-26.3 L/MIN15 GAL/MIN, 56.3 L/MINScrewN/AFluorocarbon
FP101S780V
Backordered
Hydraulic Valve Systems Division3500n/a-15-15 to +400N/A15FluorocarbonPressure CompensatedFlow Regulator ValveManually operated45-2000 SSU (6 to 420 cSt)n/aISO 4406 18/16/13, SAE Class 416ScrewPriority Flow+4006.3-9.3 gal/min This is the regulated flow range (min - max)20%C10-3n/a150.535009Mineral-based or synthetic hydraulic fluidsn/aHydraulic Systems DivisionAll parts steel. All operating parts hardened steel6.3-9.3 GAL/MIN, 23.6-34.9 L/MIN15 GAL/MIN, 56.3 L/MINScrewN/AFluorocarbon
J1A125TN
Backordered
Hydraulic Cartridge Systems Division5000 psin/a-34 °C-30 to +250 °F24 Gal/min40 Gal/minNitrilePressure CompensatedFlow Regulator ValveManually operated45-2000 SSU (6 to 420 cSt)6.6 GAL/MIN@11.9 GAL/MIN Inlet Gal/minISO 4406 18/16/13, SAE Class 485 NmTamper ResistantPriority Flow+121 °CN/A L/minN/A3An/a40 Gal/min0.45 kg5000 psiN/A L/minMineral-based or synthetic hydraulic fluidsn/aMobile Hydraulic Systems Division EuropeAll parts steel. All operating parts hardened steelN/A40 GAL/MIN,150 L/MINTamper Resistant6.6 GAL/MIN@11.9 GAL/MIN Inlet, 25 L/MIN@45 L/MIN InletNitrile