• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Body Material
  • Cavity Size
  • Configuration
  • Division
  • Drain Option
  • Filter Efficiency Rating
  • Flow Direction
  • Flow Rate
  • For Fluid Type
More Filters...

3 Way Pilot Operated Directional Control Valves

Picture for category 3 Way Pilot Operated Directional Control Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s series of 3-way, pilot-operated directional control valves feature a strong design for maximum durability and performance that can operate with hydraulic system flows as high as 90 lpm and pressures up to 420 bar. The high pressure and flow capabilities of Parker’s selection make these valves suitable for high flow switching, diverting, bypassing, or unloading applications within a broad range of markets, such as the agriculture, construction, material handling and industrial markets.

Normally-open or normally-closed options are available depending on application needs, and can even be configured with a vent to atmosphere option for the spring chamber. Parker’s spring chamber vent to atmosphere design is especially beneficial when high pilot pressures are not readily available, which will help ensure proper valve and system functionality.

Markets:
• Aerial
• Agricultural Machinery
• Construction Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile

Features/Benefits:
• High flow capacity
• Multiple switching pressure options
• Sealed pilot option available
• Hardened working parts for maximum durability
• All external parts zinc plated

Applications:
• Bypass flow paths
• Diverter for hydrostatic transmission cooling or filtration
• Enabling/disabling functions
• Enabling/disabling hydraulic subsystems
• Regen functions

Additional Technical Insight:
Parker’s 3-way, pilot-operated series of directional control valves are available both normally-open and normally-closed, with flow and pressure ranging up to 90 lpm (24 gpm) and 420 bar (6,000 psi) respectively. Two versions of both the normally-open and normally-closed are available at varying flow and pressure ratings depending on the application needs. This series of valve acts as flow diverters and redirects the hydraulic fluid’s flow path from the valve’s neutral position to its shifted position by providing external pilot pressure to port 1 (nose) of the valve. The neutral or un-shifted position of the normally-open valves allow bidirectional flow from port 3 to port 2, with the 4th port blocked. When pilot pressure is provided to port 1, the spool shifts and then redirects the flow to between the 3rd and 4th port, blocking port 2. There is a selection of valves in this family that vent to atmosphere, allowing pressure equalization in the spring chamber. The remaining valves in this family vent the spring chamber internally through the 4th port, and as a result it is advised that port 4 is located on the lower pressure side of the valve and/or the tank line. Also, any additional pressure seen at port 4 is additive to the spring setting, which may impact the pilot pressure necessary to shift the valve. Pilot pressures of 2.8 bar (40 psi), 5.5 bar (80 psi), and 11 bar (160 psi) are available as standard options on the lower flow valves, and pilot pressures of 5 bar (73 psi) and 10 bar (145 psi) are available for the higher flow valves.

For all valves where the spring chamber is vented internally, the 4th port should be connected to the lower pressure flow path and/or ideally the tank line.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPartner AvailablePriceWeightOperation TypeSeal MaterialBody MaterialMaximum Operating PressureMinimum Operating TemperatureMaximum Kinematic ViscosityDivisionPilot LocationInstallation TorqueMaximum Inlet Pressure RatingFlow RateCavity SizeMaximum Flow RateFor Fluid TypeMaximum Operating TemperatureConfigurationValve MaterialOperating TemperatureFilter Efficiency RatingFunctionLeak RateDrain OptionActuation TypeFlow DirectionSwitching PressureSealed Pilot IncludedStandard Flow Rate SettingSeal MaterialConfigurationFlow RateFlow DirectionSwitching PressureSealed Pilot Included
DH103A04V
Backordered
0.23 kgPilot OperatedFluorocarbonn/a3500 psi-26 °C45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionExternal22 Nm3500 psi10 Gal/minC10-410 Gal/minMineral-based or synthetic hydraulic fluids+204 °CNormally OpenAll parts steel. All operating parts hardened steel-15 to +400 °FISO 4406 18/16/13, SAE Class 4Directional Control50 @ 3500 PSI (240 BAR) cm3/minVent to AtmospherePilot to shift2-3 Neutral, 3-4 Piloted40 psiN/AN/A Gal/minFluorocarbonNormally Open10 GAL/MIN, 38 L/MIN2-3 Neutral, 3-4 Piloted40 PSI, 2.8 BARN/A
DH103C16V
Backordered
0.23 kgPilot OperatedFluorocarbonn/a3500 psi-15 °F45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionExternal16 lb-ft240 bar10 Gal/minC10-410 Gal/minMineral-based or synthetic hydraulic fluids+400 °FNormally OpenAll parts steel. All operating parts hardened steel-26 to +204 °CISO 4406 18/16/13, SAE Class 4Directional Control50 @ 3500 PSI (240 BAR) cm3/minInternalPilot to shift2-3 Neutral, 3-4 Piloted160 psiN/AN/A Gal/minFluorocarbonNormally Open10 GAL/MIN, 38 L/MIN2-3 Neutral, 3-4 Piloted160 PSI, 11 BARN/A
N04B4-10.0N
Backordered
0.17 kgPilot OperatedNitrilen/a6000 psi-30 °F45-2000 SSU (6 to 420 cSt)Mobile Hydraulic Systems Division EuropeExternal50 Nm420 bar24 Gal/minC10-424 Gal/minMineral-based or synthetic hydraulic fluids+121 °CSelectorAll parts steel. All operating parts hardened steel-34 to +121 °CISO 4406 18/16/13, SAE Class 4Directional Control55 @ 1450 PSI (100 BAR) cm3/minInternalPilot to shift2-3 Neutral, 3-4 Piloted10 barNo13 Gal/minNitrileSelector24 GAL/MIN, 90 L/MIN2-3 Neutral, 3-4 Piloted145 PSI, 10 BARNo
N04B4-5.0VS
Backordered
0.17 kgPilot OperatedFluorocarbonn/a420 bar-26 °C45-2000 SSU (6 to 420 cSt)Mobile Hydraulic Systems Division EuropeExternal50 Nm6000 psi24 Gal/minC10-490 L/minMineral-based or synthetic hydraulic fluids+400 °FSelectorAll parts steel. All operating parts hardened steel-26 to +204 °CISO 4406 18/16/13, SAE Class 4Directional Control55 @ 1450 PSI (100 BAR) cm3/minInternalPilot to shift2-3 Neutral, 3-4 Piloted73 psiYes13 Gal/minFluorocarbonSelector24 GAL/MIN, 90 L/MIN2-3 Neutral, 3-4 Piloted73 PSI, 5 BARYes
N04G4-15.0N
Backordered
0.48 lbPilot OperatedNitrilen/a6000 psi-34 °C45-2000 SSU (6 to 420 cSt)Mobile Hydraulic Systems Division EuropeExternal50 Nm420 bar85 L/minC10-490 L/minMineral-based or synthetic hydraulic fluids+121 °COpen TransitionAll parts steel. All operating parts hardened steel-30 to +250 °FISO 4406 18/16/13, SAE Class 4Directional Control55 @ 1450 PSI (100 BAR) cm3/minVent to AtmospherePilot to shift2-3 Neutral, 3-4 Piloted15 barNo13 Gal/minNitrileOpen Transition22.5 GAL/MIN, 85 LPM2-3 Neutral, 3-4 Piloted218 PSI, 15 BARNo
N04G4-9.0N
Backordered
0.48 lbPilot OperatedNitrilen/a6000 psi-34 °C45-2000 SSU (6 to 420 cSt)Mobile Hydraulic Systems Division EuropeExternal50 Nm420 bar85 L/minC10-490 L/minMineral-based or synthetic hydraulic fluids+250 °FOpen TransitionAll parts steel. All operating parts hardened steel-30 to +250 °FISO 4406 18/16/13, SAE Class 4Directional Control55 @ 1450 PSI (100 BAR) cm3/minVent to AtmospherePilot to shift2-3 Neutral, 3-4 Piloted131 psiNo13 Gal/minNitrileOpen Transition22.5 GAL/MIN, 85 LPM2-3 Neutral, 3-4 Piloted131 PSI, 9 BARNo
N04G4-9.0NS
Backordered
0.22 kgPilot OperatedNitrilen/a6000 psi-34 °C45-2000 SSU (6 to 420 cSt)Mobile Hydraulic Systems Division EuropeExternal37 lb-ft6000 psi85 L/minC10-490 L/minMineral-based or synthetic hydraulic fluids+250 °FOpen TransitionAll parts steel. All operating parts hardened steel-34 to +121 °CISO 4406 18/16/13, SAE Class 4Directional Control55 @ 1450 PSI (100 BAR) cm3/minVent to AtmospherePilot to shift2-3 Neutral, 3-4 Piloted9 barYes13 Gal/minNitrileOpen Transition22.5 GAL/MIN, 85 LPM2-3 Neutral, 3-4 Piloted131 PSI, 9 BARYes
N04G4-9.0V
Backordered
0.48 lbPilot OperatedFluorocarbonn/a420 bar-15 °F45-2000 SSU (6 to 420 cSt)Mobile Hydraulic Systems Division EuropeExternal37 lb-ft420 bar85 L/minC10-424 Gal/minMineral-based or synthetic hydraulic fluids+204 °COpen TransitionAll parts steel. All operating parts hardened steel-15 to +400 °FISO 4406 18/16/13, SAE Class 4Directional Control55 @ 1450 PSI (100 BAR) cm3/minVent to AtmospherePilot to shift2-3 Neutral, 3-4 Piloted131 psiNo13 Gal/minFluorocarbonOpen Transition22.5 GAL/MIN, 85 LPM2-3 Neutral, 3-4 Piloted131 PSI, 9 BARNo