• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Adjustment Mechanism
  • Body Material
  • Cavity Size
  • Division
  • Division
  • Filter Efficiency Rating
  • Flow Direction
  • Flow Rate
  • For Fluid Type
More Filters...

Standard Pilot Vented Load Control Valves

Picture for category Standard Pilot Vented Load Control Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s vented to atmosphere load holding/counterbalance valves are a combination of a relief, sequence, and flow control valve that can handle pressures up to 350 bar (5000 psi) and flows up to 113 lpm (30 gpm). These robust valves allow the operator to maintain control of the load by preventing it from overrunning the pump while also protecting against thermal expansion. The wide selection of pilot ratios enables the valve to open at pressures much lower than the spring pressure setting, allowing consistent control of the load throughout its lowering cycle. Because these valves spring chamber are vented to atmosphere, the valve will not be affected by changes in return pressure. Parker’s vented load holding valves are ideal in closed center circuits where there is need to control pressure using an auxiliary relief valve.

Markets:
• Aerial
• Construction Equipment
• Material Handling Equipment
• Miscellaneous Industrial
• Miscellaneous Mobile

Features/Benefits:
• Vented to atmosphere, no additional drain line required
• Hardened, precision ground parts for durability
• Poppet style construction with minimal leakage
• Tamperproof versions available
• Single cartridge valve with integral reverse flow check valve
• Available pilot ratios from 8:1 to 3:1
• All external parts zinc plated

Applications:
• Load holding
• Position holding

Additional Technical Insight:
The load control valves are load assisted i.e the pilot pressure acts on the difference between the setting and the load at the pilot ratio.
The valve should always be set at a minimum of 30% higher than the maximum load induced pressure to ensure the valve closes correctly.
Sizing a counterbalance valve needs care in that the flow required is usually higher than system pump flow, as in the case with a cylinder application (retract flow could be twice the system flow) though oversizing the valve could cause instability.
Because of  dynamic load variations in many applications, it may be necessary to use a lower pilot ratio or fit an orifice in the pilot line in order to gain stability.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPartner AvailablePriceSeal MaterialMaximum Operating PressureDivisionMaximum Flow RateMaximum Kinematic ViscosityDivisionPilot LocationMinimum Operating TemperatureBody MaterialWeightAdjustment MechanismMaximum Inlet Pressure RatingFunctionPilot Pressure RatioHolding PressureCavity SizeFor Fluid TypeMaximum Operating TemperatureValve MaterialOperating TemperatureFilter Efficiency RatingInstallation TorqueActuation TypeFlow RateLeak RatePort SizeMounting TypeFlow DirectionPressure Control RangePressure Control SensitivitySeal MaterialAdjustment MechanismPilot Pressure RatioPressure Control RangeMaximum Flow RatePort SizeMounting TypeHolding Pressure
MHB-015-WBDE-51N
Backordered
Nitrile3000 psiHydraulic Cartridge Systems Division15 Gal/min45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionInternal-30 °FAluminum1.36 kgTamper Resistant3000 psiCounterbalance Valve3:1210 barn/aMineral-based or synthetic hydraulic fluids+250 °FAll parts steel. All operating parts hardened steel-30 to +250 °FISO 4406 18/16/13, SAE Class 4N/A lb-ftPilot Operated, Vented56 L/min5 @ 80% of setting drops/minSAE-6Double InlineCylinder port C, Valve port V105-210 barN/A psiNitrileTamper Resistant3:1500-1500 PSI, 34.5-103.4 BAR15 GAL/MIN, 56 L/MINSAE-6Double Inline1500 PSI, 103.4 BAR
MHB-030-WJBH-52E
Backordered
Nitrile210 barHydraulic Cartridge Systems Division30 Gal/min45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionExternal-30 °FAluminum2.5 lbTamper Resistant210 barCounterbalance Valve10:13000 psin/aMineral-based or synthetic hydraulic fluids+250 °FAll parts steel. All operating parts hardened steel-30 to +250 °FISO 4406 18/16/13, SAE Class 4N/A lb-ftPilot Operated, Vented112.5 L/min5 @ 80% of setting drops/minSAE-8Single GasketCylinder port C, Valve port V, Pilot port P105-210 barN/A barNitrileTamper Resistant10:1105-210 B30 GAL/MIN, 112.5 L/MINSAE-8Single Gasket3000 PSI, 210 BAR
MHC-010-VASC-00B
Backordered
Nitrile350 barHydraulic Cartridge Systems Division10 Gal/min45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionExternal-30 °Fn/a0.38 kgStandard (adjustable)350 barCounterbalance Valve1:1500 psiCDD-1010Mineral-based or synthetic hydraulic fluids+121 °CAll parts steel. All operating parts hardened steel-34 to +121 °CISO 4406 18/16/13, SAE Class 468-75 NmPilot Operated, Vented10 Gal/min5 @ 80% of setting drops/minn/aThreaded Cartridge ValveCylinder port 2, Valve port 3, Pilot port 1N/A psiN/A psiNitrileStandard (adjustable)1:1N/A10 GAL/MIN, 37.5 L/MINn/aThreaded Cartridge Valve500 PSI, 34.5 BAR
MHC-010-VBNF-00F
Backordered
Fluorocarbon5000 psiHydraulic Cartridge Systems Division10 Gal/min45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionExternal-26 °Cn/a0.38 kgShimmed (non-adjustable)5000 psiCounterbalance Valve4:12000 psiCDD-1010Mineral-based or synthetic hydraulic fluids+204 °CAll parts steel. All operating parts hardened steel-26 to +204 °CISO 4406 18/16/13, SAE Class 468-75 NmPilot Operated, Vented37.5 L/min5 @ 80% of setting drops/minn/aThreaded Cartridge ValveCylinder port 2, Valve port 3, Pilot port 1N/A psiN/A barFluorocarbonShimmed (non-adjustable)4:1N/A10 GAL/MIN, 37.5 L/MINn/aThreaded Cartridge Valve2000 PSI, 140 BAR
MHC-010-VFND-00B
Backordered
Nitrile350 barHydraulic Cartridge Systems Division10 Gal/min45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionExternal-30 °Fn/a0.88 lbShimmed (non-adjustable)5000 psiCounterbalance Valve7:169 barCDD-1010Mineral-based or synthetic hydraulic fluids+250 °FAll parts steel. All operating parts hardened steel-30 to +250 °FISO 4406 18/16/13, SAE Class 450-55 lb-ftPilot Operated, Vented10 Gal/min5 @ 80% of setting drops/minn/aThreaded Cartridge ValveCylinder port 2, Valve port 3, Pilot port 1N/A barN/A psiNitrileShimmed (non-adjustable)7:1N/A10 GAL/MIN, 37.5 L/MINn/aThreaded Cartridge Valve1000 PSI, 69 BAR
MHC-010-VFND-00F
Backordered
Fluorocarbon5000 psiHydraulic Cartridge Systems Division37.5 L/min45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionExternal-26 °Cn/a0.88 lbShimmed (non-adjustable)350 barCounterbalance Valve7:169 barCDD-1010Mineral-based or synthetic hydraulic fluids+400 °FAll parts steel. All operating parts hardened steel-15 to +400 °FISO 4406 18/16/13, SAE Class 468-75 NmPilot Operated, Vented37.5 L/min5 @ 80% of setting drops/minn/aThreaded Cartridge ValveCylinder port 2, Valve port 3, Pilot port 1N/A barN/A barFluorocarbonShimmed (non-adjustable)7:1N/A10 GAL/MIN, 37.5 L/MINn/aThreaded Cartridge Valve1000 PSI, 69 BAR
MHC-010-VFNH-00B
Backordered
Nitrile5000 psiHydraulic Cartridge Systems Division37.5 L/min45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionExternal-30 °Fn/a0.88 lbShimmed (non-adjustable)350 barCounterbalance Valve7:1210 barCDD-1010Mineral-based or synthetic hydraulic fluids+250 °FAll parts steel. All operating parts hardened steel-30 to +250 °FISO 4406 18/16/13, SAE Class 450-55 lb-ftPilot Operated, Vented37.5 L/min5 @ 80% of setting drops/minn/aThreaded Cartridge ValveCylinder port 2, Valve port 3, Pilot port 1N/A psiN/A psiNitrileShimmed (non-adjustable)7:1N/A10 GAL/MIN, 37.5 L/MINn/aThreaded Cartridge Valve3000 PSI, 210 BAR
MHC-010-VFNK-00B
Backordered
Nitrile5000Hydraulic Valve Systems Division1045-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionExternal-30n/a0.88Shimmed (non-adjustable)5000Counterbalance Valve7:15000CDD-1010Mineral-based or synthetic hydraulic fluids+250All parts steel. All operating parts hardened steel-30 to +250ISO 4406 18/16/13, SAE Class 468-75Pilot Operated, Vented105 @ 80% of settingn/aThreaded Cartridge ValveCylinder port 2, Valve port 3, Pilot port 1n/an/aNitrileShimmed (non-adjustable)7:1N/A10 GAL/MIN, 37.5 L/MINn/aThreaded Cartridge Valve5000 PSI, 350 BAR
MHC-010-VFSD-00B
Backordered
Nitrile5000 psiHydraulic Cartridge Systems Division10 Gal/min45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionExternal-30 °Fn/a0.88 lbStandard (adjustable)350 barCounterbalance Valve7:169 barCDD-1010Mineral-based or synthetic hydraulic fluids+250 °FAll parts steel. All operating parts hardened steel-34 to +121 °CISO 4406 18/16/13, SAE Class 468-75 NmPilot Operated, Vented37.5 L/min5 @ 80% of setting drops/minn/aThreaded Cartridge ValveCylinder port 2, Valve port 3, Pilot port 1N/A barN/A psiNitrileStandard (adjustable)7:1N/A10 GAL/MIN, 37.5 L/MINn/aThreaded Cartridge Valve1000 PSI, 69 BAR
MHC-010-VFSF-00B
Backordered
Nitrile5000 psiHydraulic Cartridge Systems Division10 Gal/min45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionExternal-34 °Cn/a0.38 kgStandard (adjustable)5000 psiCounterbalance Valve7:12000 psiCDD-1010Mineral-based or synthetic hydraulic fluids+250 °FAll parts steel. All operating parts hardened steel-34 to +121 °CISO 4406 18/16/13, SAE Class 450-55 lb-ftPilot Operated, Vented37.5 L/min5 @ 80% of setting drops/minn/aThreaded Cartridge ValveCylinder port 2, Valve port 3, Pilot port 1N/A psiN/A psiNitrileStandard (adjustable)7:1N/A10 GAL/MIN, 37.5 L/MINn/aThreaded Cartridge Valve2000 PSI, 140 BAR
MHC-010-VJNK-00B
Backordered
Nitrile5000 psiHydraulic Cartridge Systems Division37.5 L/min45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionExternal-30 °Fn/a0.38 kgShimmed (non-adjustable)350 barCounterbalance Valve10:1350 barCDD-1010Mineral-based or synthetic hydraulic fluids+121 °CAll parts steel. All operating parts hardened steel-30 to +250 °FISO 4406 18/16/13, SAE Class 468-75 NmPilot Operated, Vented37.5 L/min5 @ 80% of setting drops/minn/aThreaded Cartridge ValveCylinder port 2, Valve port 3, Pilot port 1N/A psiN/A barNitrileShimmed (non-adjustable)10:1N/A10 GAL/MIN, 37.5 L/MINn/aThreaded Cartridge Valve5000 PSI, 350 BAR
MHC-010-VJNK-00F
Backordered
Fluorocarbon5000 psiHydraulic Cartridge Systems Division37.5 L/min45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionExternal-26 °Cn/a0.38 kgShimmed (non-adjustable)350 barCounterbalance Valve10:15000 psiCDD-1010Mineral-based or synthetic hydraulic fluids+400 °FAll parts steel. All operating parts hardened steel-15 to +400 °FISO 4406 18/16/13, SAE Class 450-55 lb-ftPilot Operated, Vented10 Gal/min5 @ 80% of setting drops/minn/aThreaded Cartridge ValveCylinder port 2, Valve port 3, Pilot port 1N/A psiN/A barFluorocarbonShimmed (non-adjustable)10:1N/A10 GAL/MIN, 37.5 L/MINn/aThreaded Cartridge Valve5000 PSI, 350 BAR
MHC-010-VJSK-00B
Backordered
Nitrile5000Hydraulic Valve Systems Division1045-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionExternal-30n/a0.88Standard (adjustable)5000Counterbalance Valve10:15000CDD-1010Mineral-based or synthetic hydraulic fluids+250All parts steel. All operating parts hardened steel-30 to +250ISO 4406 18/16/13, SAE Class 468-75Pilot Operated, Vented105 @ 80% of settingn/aThreaded Cartridge ValveCylinder port 2, Valve port 3, Pilot port 1n/an/aNitrileStandard (adjustable)10:1N/A10 GAL/MIN, 37.5 L/MINn/aThreaded Cartridge Valve5000 PSI, 350 BAR
MHC-022-VJNH-00B
Backordered
Nitrile5000 psiHydraulic Cartridge Systems Division25 Gal/min45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionExternal-30 °Fn/a0.88 lbShimmed (non-adjustable)350 barCounterbalance Valve10:13000 psiCDD-1036Mineral-based or synthetic hydraulic fluids+121 °CAll parts steel. All operating parts hardened steel-34 to +121 °CISO 4406 18/16/13, SAE Class 475-80 lb-ftPilot Operated, Vented25 Gal/min5 @ 80% of setting drops/minn/aThreaded Cartridge ValveCylinder port 2, Valve port 3, Pilot port 1N/A psiN/A barNitrileShimmed (non-adjustable)10:1N/A25 GAL/MIN, 93.75 L/MINn/aThreaded Cartridge Valve3000 PSI, 210 BAR
MHC-022-VJNH-00F
Backordered
Fluorocarbon5000 psiHydraulic Cartridge Systems Division25 Gal/min45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionExternal-15 °Fn/a0.88 lbShimmed (non-adjustable)350 barCounterbalance Valve10:1210 barCDD-1036Mineral-based or synthetic hydraulic fluids+400 °FAll parts steel. All operating parts hardened steel-26 to +204 °CISO 4406 18/16/13, SAE Class 475-80 lb-ftPilot Operated, Vented93.75 L/min5 @ 80% of setting drops/minn/aThreaded Cartridge ValveCylinder port 2, Valve port 3, Pilot port 1N/A psiN/A psiFluorocarbonShimmed (non-adjustable)10:1N/A25 GAL/MIN, 93.75 L/MINn/aThreaded Cartridge Valve3000 PSI, 210 BAR
MHC-022-VJSK-00F
Backordered
Fluorocarbon5000 psiHydraulic Cartridge Systems Division25 Gal/min45-2000 SSU (6 to 420 cSt)Hydraulic Systems DivisionExternal-15 °Fn/a0.38 kgStandard (adjustable)5000 psiCounterbalance Valve10:1350 barCDD-1036Mineral-based or synthetic hydraulic fluids+400 °FAll parts steel. All operating parts hardened steel-15 to +400 °FISO 4406 18/16/13, SAE Class 475-80 lb-ftPilot Operated, Vented25 Gal/min5 @ 80% of setting drops/minn/aThreaded Cartridge ValveCylinder port 2, Valve port 3, Pilot port 1N/A psiN/A barFluorocarbonStandard (adjustable)10:1N/A25 GAL/MIN, 93.75 L/MINn/aThreaded Cartridge Valve5000 PSI, 350 BAR