• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Body Material
  • Connection Type
  • Division
  • For Fluid Type
  • Function
  • Maximum Flow Rate
  • Maximum Operating Pressure
  • Maximum Operating Temperature
  • Minimum Operating Temperature
More Filters...

Pilot Operated Directional Control Valve - Series D31DW, D31NW, D41VW, D91VW, D111VW

Picture for category Pilot Operated Directional Control Valve - Series D31DW, D31NW, D41VW, D91VW, D111VW

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker's robust and durable pilot operated directional control valves series D31DW, D31NW, D*1VW are almost universally applicable and ensure a reliable operation. A wide variety of spools and options allows to design an unlimited number of hydraulic circuits.

The pilot operated directional control valves are available in 4 sizes: D31DW (standard) and D31NW (high flow) in NG10/NFPA D05, D41VW in NG16/NFPA D07, D91VW (for port diameter up to 32 mm) in NG25/NFPA D08 and D111VW in NG32/NFPA D10.

All sizes are optionally available with position control or as explosion-proof version according to ATEX and IECEx.

Markets:
• Industrial

Features/Benefits:
• Proven robust design that represents our long-term experience in hydraulics
• Wide range of spools - suitable for almost all hydraulic circuits
• High functional limits – low forces resulting in safe operation also at high flow rates
• Low pressure drop – resulting in low energy losses in operation
• Short delivery time – no warehousing necessary
• Optionally with position control
• Optionally without manual override
• Optionally as explosion-proof version

Applications:
• Suitable for general hydraulic applications

Explosion-proof versions
The valves are not only ATEX certified (explosion proof class is Ex e mb II T4 Gb for use in zone 1 and 2) but also equipped with IECEx compliant solenoids which are  certified  in  accordance with IECEx standard for equipment class 2 G. All explosion-proof solenoids are DC design. The valves for AC operate with integrated rectifier.

Note:
The minimum pilot pressure must be ensured for all operating conditions of the directional valve. Additionally spools with a P to T connection in the deenergized  position  need  an  external  pressure  supply (external inlet) or an integral check valve.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPartner AvailablePriceMaximum Operating TemperatureMaximum Operating PressureSeal MaterialOperation TypeBody MaterialFor Fluid TypeActuation TypeMinimum Operating TemperatureFunctionProduct SeriesConnection TypeMounting TypeMaximum Flow RateWeightDivisionSeal MaterialAdditional OptionsPort ConnectionMarkingInput VoltagePilot Inlet / Drain LocationsSpool PositionSolenoid OptionSpool CodeMaximum Flow RateBore Diameter
D91VW015E1NJW
Backordered
60 °C350 barNBRPilotCast IronHydraulic Oil According to DIN 51524Solenoid-25 °C3-WayDirectional Control ValveConnector as per EN 175301-803Subplate mounting700 L/min17.9 kgHydraulic Valve Systems Division EuropeNBRNANG25 / CETOP 08Standard24 VDCInternal/external2 positions, spring offset in position 0, operated in position aStandard solenoid without options015700 L/min32 mm
D91VW015E4NJW
Backordered
60 °C350 barNBRPilotCast IronHydraulic Oil According to DIN 51524Solenoid-25 °C3-WayDirectional Control ValveConnector as per EN 175301-803Subplate mounting700 L/min17.9 kgIndustrial Systems Division EuropeNBRNANG25 / CETOP 08Standard24 VDCInternal/internal2 positions, spring offset in position 0, operated in position aStandard solenoid without options015700 L/min32 mm
D91VW016F1VJWI2N
Backordered
60 °C350 barFPMPilotCast IronWater GlycolSolenoid-20 °C3-WayDirectional Control ValveConnector as per EN 175301-803Subplate mounting700 L/min17.9 kgIndustrial Systems Division EuropeFPMPosition control, end position monitored, side BNG25 / CETOP 08Standard24 VDCInternal/external2 positions, operated in position 0, spring offset in position bStandard solenoid without options016700 L/min32 mm
D91VW020B1NJW
Backordered
60 °C350 barNBRPilotCast IronHydraulic Oil According to DIN 51524Solenoid-25 °C3-WayDirectional Control ValveConnector as per EN 175301-803Subplate mounting700 L/min17.9 kgHydraulic Valve Systems Division EuropeNBRNANG25 / CETOP 08Standard24 VDCInternal/external2 positions, spring offset in position b, operated in position aStandard solenoid without options020700 L/min32 mm
D91VW020B1NJW3C
Backordered
60 °C350 barNBRPilotCast IronHydraulic Oil According to DIN 51524Solenoid-25 °C3-WayDirectional Control ValveConnector as per EN 175301-803Subplate mounting700 L/min17.9 kgIndustrial Systems Division EuropeNBRPilot with pressure reducing valveNG25 / CETOP 08Standard24 VDCInternal/external2 positions, spring offset in position b, operated in position aStandard solenoid without options020700 L/min32 mm
D91VW020B1NJWI2N
Backordered
60 °C350 barNBRPilotCast IronHydraulic Oil According to DIN 51524Solenoid-20 °C3-WayDirectional Control ValveConnector as per EN 175301-803Subplate mounting700 L/min17.9 kgIndustrial Systems Division EuropeNBRPosition control, end position monitored, side BNG25 / CETOP 08Standard24 VDCInternal/external2 positions, spring offset in position b, operated in position aStandard solenoid without options020700 L/min32 mm
D91VW020B1NJWI5N
Backordered
60 °C350 barNBRPilotCast IronHydraulic Oil According to DIN 51524Solenoid-20 °C3-WayDirectional Control ValveConnector as per EN 175301-803Subplate mounting700 L/min17.9 kgIndustrial Systems Division EuropeNBRPosition control, start position monitored, side BNG25 / CETOP 08Standard24 VDCInternal/external2 positions, spring offset in position b, operated in position aStandard solenoid without options020700 L/min32 mm
D91VW020B1NJWTI5N
Backordered
60 °C350 barNBRPilotCast IronHydraulic Oil According to DIN 51524Solenoid-20 °C3-WayDirectional Control ValveConnector as per EN 175301-803Subplate mounting700 L/min17.9 kgIndustrial Systems Division EuropeNBRPosition control, start position monitored, side BNG25 / CETOP 08Standard24 VDCInternal/external2 positions, spring offset in position b, operated in position aWithout manual override020700 L/min32 mm
D91VW020B1NTW
Backordered
60 °C350 barNBRPilotCast IronHydraulic Oil According to DIN 51524Solenoid-25 °C3-WayDirectional Control ValveConnector as per EN 175301-803Subplate mounting700 L/min17.9 kgIndustrial Systems Division EuropeNBRNANG25 / CETOP 08Standard230/240 VAC, 50/60 HzInternal/external2 positions, spring offset in position b, operated in position aStandard solenoid without options020700 L/min32 mm
D91VW020B1VUWI2N
Backordered
60 °C350 barFPMPilotCast IronWater GlycolSolenoid-20 °C3-WayDirectional Control ValveConnector as per EN 175301-803Subplate mounting700 L/min17.9 kgIndustrial Systems Division EuropeFPMPosition control, end position monitored, side BNG25 / CETOP 08Standard98 VDCInternal/external2 positions, spring offset in position b, operated in position aStandard solenoid without options020700 L/min32 mm
D91VW020B2NJW1R
Backordered
60 °C350 barNBRPilotCast IronHydraulic Oil According to DIN 51524Solenoid-25 °C3-WayDirectional Control ValveConnector as per EN 175301-803Subplate mounting700 L/min17.9 kgIndustrial Systems Division EuropeNBRNANG25 / CETOP 08Standard24 VDCExternal/external2 positions, spring offset in position b, operated in position aStandard solenoid without options020700 L/min32 mm
D91VW020B2NJW3B
Backordered
60 °C350 barNBRPilotCast IronHydraulic Oil According to DIN 51524Solenoid-25 °C3-WayDirectional Control ValveConnector as per EN 175301-803Subplate mounting700 L/min17.9 kgIndustrial Systems Division EuropeNBRPilot choke, meter-inNG25 / CETOP 08Standard24 VDCExternal/external2 positions, spring offset in position b, operated in position aStandard solenoid without options020700 L/min32 mm
D91VW020B2NJWI2N
Backordered
60 °C350 barNBRPilotCast IronHydraulic Oil According to DIN 51524Solenoid-20 °C3-WayDirectional Control ValveConnector as per EN 175301-803Subplate mounting700 L/min17.9 kgIndustrial Systems Division EuropeNBRPosition control, end position monitored, side BNG25 / CETOP 08Standard24 VDCExternal/external2 positions, spring offset in position b, operated in position aStandard solenoid without options020700 L/min32 mm
D91VW020B2NYW
Backordered
60 °C350 barNBRPilotCast IronHydraulic Oil According to DIN 51524Solenoid-25 °C3-WayDirectional Control ValveConnector as per EN 175301-803Subplate mounting700 L/min17.9 kgHydraulic Valve Systems Division EuropeNBRNANG25 / CETOP 08Standard110/120 VAC, 50/60 HzExternal/external2 positions, spring offset in position b, operated in position aStandard solenoid without options020700 L/min32 mm
D91VW020B2VJW
Backordered
60 °C350 barFPMPilotCast IronWater GlycolSolenoid-25 °C3-WayDirectional Control ValveConnector as per EN 175301-803Subplate mounting700 L/min17.9 kgHydraulic Valve Systems Division EuropeFPMNANG25 / CETOP 08Standard24 VDCExternal/external2 positions, spring offset in position b, operated in position aStandard solenoid without options020700 L/min32 mm
D91VW020B4NJEE
Backordered
60 °C350 barNBRPilotCast IronHydraulic Oil According to DIN 51524Solenoid-25 °C3-WayDirectional Control ValveExplosion Proof with Cable GlandsSubplate mounting700 L/min17.9 kgHydraulic Valve Systems Division EuropeNBRNANG25 / CETOP 08Standard24 VDCInternal/internal2 positions, spring offset in position b, operated in position aExplosion proof solenoids Ex e mb II T4Gb + IECEx conformity020700 L/min32 mm
D91VW020B4NJW
Backordered
60 °C350 barNBRPilotCast IronHydraulic Oil According to DIN 51524Solenoid-25 °C3-WayDirectional Control ValveConnector as per EN 175301-803Subplate mounting700 L/min17.9 kgHydraulic Valve Systems Division EuropeNBRNANG25 / CETOP 08Standard24 VDCInternal/internal2 positions, spring offset in position b, operated in position aStandard solenoid without options020700 L/min32 mm
D91VW020B4NJW7E
Backordered
60 °C350 barNBRPilotCast IronHydraulic Oil According to DIN 51524Solenoid-25 °C3-WayDirectional Control ValveConnector as per EN 175301-803Subplate mounting700 L/min17.9 kgIndustrial Systems Division EuropeNBRNANG25 / CETOP 08Standard24 VDCInternal/internal2 positions, spring offset in position b, operated in position aStandard solenoid without options020700 L/min32 mm
D91VW020B4NJWI2N
Backordered
60 °C350 barNBRPilotCast IronHydraulic Oil According to DIN 51524Solenoid-20 °C3-WayDirectional Control ValveConnector as per EN 175301-803Subplate mounting700 L/min17.9 kgHydraulic Valve Systems Division EuropeNBRPosition control, end position monitored, side BNG25 / CETOP 08Standard24 VDCInternal/internal2 positions, spring offset in position b, operated in position aStandard solenoid without options020700 L/min32 mm
D91VW020B4NJWI5N
Backordered
60 °C350 barNBRPilotCast IronHydraulic Oil According to DIN 51524Solenoid-20 °C3-WayDirectional Control ValveConnector as per EN 175301-803Subplate mounting700 L/min17.9 kgHydraulic Valve Systems Division EuropeNBRPosition control, start position monitored, side BNG25 / CETOP 08Standard24 VDCInternal/internal2 positions, spring offset in position b, operated in position aStandard solenoid without options020700 L/min32 mm