Pilot Operated Directional Control Valve - Series D31DW, D31NW, D41VW, D91VW, D111VW - D91VW001F2NGWTI5N

Setting standards for pilot operated on-/off valves in terms of functional limits and pressure drop, Parker's series D31DW, D31NW, D*1VW are suitable for practically any industrial application. Optionally available as ex-proof version.
Availability:
Backordered
SKU: D91VW001F2NGWTI5N
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
Maximum Operating Temperature60 °CMinimum Operating Temperature-20 °C
Maximum Operating Pressure350 barSeal MaterialNBR
Operation TypePilotBody MaterialCast Iron
For Fluid TypeHydraulic Oil According to DIN 51524Actuation TypeSolenoid
Function3-WayProduct SeriesDirectional Control Valve
Connection TypeConnector as per EN 175301-803Mounting TypeSubplate mounting
Maximum Flow Rate700 L/minWeight17.9 kg
DivisionHydraulic Valve Systems Division Europe
Seal MaterialNBRPort ConnectionNG25 / CETOP 08
MarkingStandardInput Voltage205 VDC
Pilot Inlet / Drain LocationsExternal/externalSpool Code001
Solenoid OptionWithout manual overrideAdditional OptionsPosition control, start position monitored, side B
Spool Position2 positions, operated in position 0, spring offset in position bMaximum Flow Rate700 L/min
Bore Diameter32 mm
Product resources

Literature and Reference Materials

Compliance, Certifications & Safety