• Availability & Price
  • Search SKU
Filter by attributes
  • Application
  • Brand
  • Division
  • Division
  • For Fluid Type
  • Indicator Pressure Setting
  • Industry
  • Materials of Construction
  • Mounting Type
  • Operating Pressure
More Filters...

High Pressure Inline Hydraulic Oil Filter – iProtect® EPF Series

Picture for category High Pressure Inline Hydraulic Oil Filter – iProtect® EPF Series

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The Parker EPF Series is a high pressure, inline hydraulic oil filter that provides high-efficiency filtration for equipment in demanding environments, including mining, construction, marine, drilling, and agricultural applications. A unique feature of the EPF Series is that the filter element remains inside the filter bowl when performing a change-out. This can save over 500 mm of space envelope in comparison with traditional high pressure filters on the market. The filter element core is also reusable, which reduces waste by up to 50% when compared to conventional filters with non-reusable elements.

EPF Series filters serve as a highly economical filtration solution in high pressure range applications (up to 450 bar), where compact envelopes and excellent fatigue pressure ratings are critical. Specific examples include (but are not limited to) mobile working hydraulics, wind turbines, drive systems, pilot line filtration systems, servo controls, industrial working hydraulics, control systems, and reverse flow valve applications.

The patented design of the filter element allows for integration of the bypass valve and element core as re-usable parts in the filter bowl. This makes the filter secure and eliminates the risk of forgetting to re-install reusable parts during maintenance. Bypass settings are available up to 7 bar (100 psi) or no bypass versions when using patented, high strength filter elements. The principle is based on differential pressure measurement across the filter element.

The EPF Series is designed for use with EPF Series Replacement Elements and is available with various port connection types, filtration media (2, 5, 10, and 20 micron), indicators, and flow capacities (up to 700 L/min) to meet the unique requirements of customers’ hydraulic circuits

Features and Benefits:
• Prevents damaging of hydraulic circuits or machinery done by dirt, sand, dust, metal, etc.

• Lengthens time in between required maintenance intervals, reduces operating costs, and extends overall equipment/machine operational life

• Compact filter design can save over 500 mm of space envelope when compared to traditional inline hydraulic filters

• Reusable element core with patented filtration technology reduces waste by up to 50% when compared to conventional filters with non-reusable elements

• A "clever" design minimizes the likelihood of installation mistakes

• Can be equipped with an optional reverse flow. This valve assembly is integrated in the element end cap and isolates the filter medium during reverse flow conditions.

• Protected aftermarket to guarantee the use of genuine products to protect equipment/machinery.

• Provides OEM branding (labelling)opportunities

• High efficiency Quantµmfiber™ glass media increases particle capture and dirt holding capacity.

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPartner AvailablePriceDivisionBrandOperating PressureOperating TemperatureTechnologyDivisionIndicator Pressure SettingIndustrySpecifications MetProduct StyleProduct SeriesApplicationMaterials of ConstructionMounting TypeFor Fluid TypeProduct TypeSeal MaterialBypass Valve (bar)Flow RateOptionsConnection TypeIndicator TypeFlow Capacity (l/min)Filter ElementBypass Valve Pressure RatingPort Connection TypeFilter Element TypeMicron Rating
EPF1102AIBPMG081EX
Backordered
Hydraulic & Industrial Process Filtration Division EMEAParker6500 psi-40 to 100 °CFiltrationHydraulic & Industrial Process Filtration Division EMEANo indicatorMiningDegree of filtration determined by multipass test according to ISO 16889.Inline FilteriProtect® EPFDrilling EquipmentHousing: Iron/SteelInlineHydraulic OilHydraulic Oil FiltersNitrile7.00 to 30 l/minAtexG½Plugged with steel plug0 to 3002 Antistatic element7.0 barG1/202 Antistatic element
EPF1102QIBM3MG081
Backordered
Hydraulic & Industrial Process Filtration Division EMEAParker450 barHydraulicsHydraulic & Industrial Process Filtration Division EMEA5 barMiningDegree of filtration determined by multipass test according to ISO 16889.Inline FilteriProtect® EPFForwardersHousing: Iron/SteelHydraulic OilHydraulic Oil FiltersNitrile7.00 to 30 l/minStandard, incl. BypassG½Visual0 to 3002QI (Microglass)7.0 barG1/202QI (Microglass)2 µm
EPF1102QIBM3MG081EX
Backordered
Hydraulic & Industrial Process Filtration Division EMEANitrile0 to 30 l/minAtexG½Visual7.0 bar02QI (Microglass)2 µm
EPF1102QIBPMG081
Backordered
Hydraulic & Industrial Process Filtration Division EMEAParker450 barHydraulicsHydraulic & Industrial Process Filtration Division EMEANo indicatorMarineDegree of filtration determined by multipass test according to ISO 16889.Inline FilteriProtect® EPFMarine Steering UnitsHousing: Iron/SteelHydraulic OilHydraulic Oil FiltersNitrile7.00 to 30 l/minStandard, incl. BypassG½Plugged with steel plug0 to 3002QI (Microglass)7.0 barG1/202QI (Microglass)2 µm
EPF1102QIBXMKIT1
Backordered
Hydraulic & Industrial Process Filtration Division EMEAParker6500 psi-40 to 100 °CHydraulicsHydraulic & Industrial Process Filtration Division EMEANo indicatorConstructionDegree of filtration determined by multipass test according to ISO 16889.Inline FilteriProtect® EPFMarine Steering UnitsHousing: Iron/SteelManifold integratedHydraulic OilHydraulic Oil FiltersNitrile7.00 to 30 l/minBowl + Element kit, incl. BypassNo filter headNo indicator0 to 3002QI (Microglass)7.0 barNo filter head02QI (Microglass)2 µm
EPF1102QIHBM3MG082
Backordered
Hydraulic & Industrial Process Filtration Division EMEAParker450 barFiltrationHydraulic & Industrial Process Filtration Division EMEA5 barAgricultureDegree of filtration determined by multipass test according to ISO 16889.Inline FilteriProtect® EPFForwardersHousing: Iron/SteelHydraulic OilHydraulic Oil FiltersNitrileNo Bypass with 5.0 bar indicator0 to 30 l/minNo bypassG½Visual0 to 3002QIH (High Strenght Microglass)No Bypass with 5.0 bar indicatorG1/202QIH (High Strength Microglass)2 µm
EPF1102QIHBPXG082
Backordered
Hydraulic & Industrial Process Filtration Division EMEAParker450 barHydraulicsHydraulic & Industrial Process Filtration Division EMEANo indicatorMarineDegree of filtration determined by multipass test according to ISO 16889.Inline FilteriProtect® EPFHydraulic PressesHousing: Iron/SteelHydraulic OilHydraulic Oil FiltersNitrileNo bypass / No indicator0 to 30 l/minNo bypassG½Plugged with steel plug0 to 3002QIH (High Strenght Microglass)No Bypass / No indicatorG1/202QIH (High Strength Microglass)2 µm
EPF1102QIHBT1MG082
Backordered
Hydraulic & Industrial Process Filtration Division EMEAParker450 barFiltrationHydraulic & Industrial Process Filtration Division EMEA5 barOil and GasDegree of filtration determined by multipass test according to ISO 16889.Inline FilteriProtect® EPFForwardersHousing: Iron/SteelHydraulic OilHydraulic Oil FiltersNitrileNo Bypass with 5.0 bar indicator0 to 30 l/minNo bypassG½Electrical NO/NC0 to 3002QIH (High Strenght Microglass)No Bypass with 5.0 bar indicatorG1/202QIH (High Strength Microglass)2 µm
EPF1102QIVM3KG081
Backordered
Hydraulic & Industrial Process Filtration Division EMEAParker450 barHydraulicsHydraulic & Industrial Process Filtration Division EMEA2.5 barMarineDegree of filtration determined by multipass test according to ISO 16889.Inline FilteriProtect® EPFForwardersHousing: Iron/SteelHydraulic OilHydraulic Oil FiltersFluorelastomer3.50 to 30 l/minStandard, incl. BypassG½Visual0 to 3002QI (Microglass)3.5 barG1/202QI (Microglass)2 µm
EPF1105QIBM3MG081
Backordered
Hydraulic & Industrial Process Filtration Division EMEAParker450 barFiltrationHydraulic & Industrial Process Filtration Division EMEA5 barConstructionDegree of filtration determined by multipass test according to ISO 16889.Inline FilteriProtect® EPFExcavatorsHousing: Iron/SteelHydraulic OilHydraulic Oil FiltersNitrile7.00 to 35 l/minStandard, incl. BypassG½Visual0 to 3505QI (Microglass)7.0 barG1/205QI (Microglass)5 µm
EPF1105QIBPKG081
Backordered
Hydraulic & Industrial Process Filtration Division EMEAParker450 barHydraulicsHydraulic & Industrial Process Filtration Division EMEANo indicatorMiningDegree of filtration determined by multipass test according to ISO 16889.Inline FilteriProtect® EPFDeck and Mobile CranesHousing: Iron/SteelHydraulic OilHydraulic Oil FiltersNitrile3.50 to 35 l/minStandard, incl. BypassG½Plugged with steel plug0 to 3505QI (Microglass)3.5 barG1/205QI (Microglass)5 µm
EPF1105QIBPMG081
Backordered
Hydraulic & Industrial Process Filtration Division EMEAParker450 barFiltrationHydraulic & Industrial Process Filtration Division EMEANo indicatorMaterial HandlingDegree of filtration determined by multipass test according to ISO 16889.Inline FilteriProtect® EPFDrilling EquipmentHousing: Iron/SteelHydraulic OilHydraulic Oil FiltersNitrile7.00 to 35 l/minStandard, incl. BypassG½Plugged with steel plug0 to 3505QI (Microglass)7.0 barG1/205QI (Microglass)5 µm
EPF1105QIBT1MG081
Backordered
Hydraulic & Industrial Process Filtration Division EMEAParker450 barFiltrationHydraulic & Industrial Process Filtration Division EMEA5 barConstructionDegree of filtration determined by multipass test according to ISO 16889.Inline FilteriProtect® EPFWind turbinesHousing: Iron/SteelHydraulic OilHydraulic Oil FiltersNitrile7.00 to 35 l/minStandard, incl. BypassG½Electrical NO/NC0 to 3505QI (Microglass)7.0 barG1/205QI (Microglass)5 µm
EPF1105QIBXKKIT1
Backordered
Hydraulic & Industrial Process Filtration Division EMEAParker450 bar-40 to 100 °CHydraulicsHydraulic & Industrial Process Filtration Division EMEANo indicatorMiningDegree of filtration determined by multipass test according to ISO 16889.Inline FilteriProtect® EPFMarine Steering UnitsHousing: Iron/SteelManifold integratedHydraulic OilHydraulic Oil FiltersNitrile3.50 to 35 l/minBowl + Element kit, incl. BypassNo filter headNo indicator0 to 3505QI (Microglass)3.5 barNo filter head05QI (Microglass)5 µm
EPF1105QIBXMKIT1
Backordered
Hydraulic & Industrial Process Filtration Division EMEAParker450 bar-40 to 100 °CHydraulicsHydraulic & Industrial Process Filtration Division EMEANo indicatorMaterial HandlingDegree of filtration determined by multipass test according to ISO 16889.Inline FilteriProtect® EPFMarine Steering UnitsHousing: Iron/SteelManifold integratedHydraulic OilHydraulic Oil FiltersNitrile7.00 to 35 l/minBowl + Element kit, incl. BypassNo filter headNo indicator0 to 3505QI (Microglass)7.0 barNo filter head05QI (Microglass)5 µm
EPF1105QIHBM3MG082
Backordered
Hydraulic & Industrial Process Filtration Division EMEAParker450 barHydraulicsHydraulic & Industrial Process Filtration Division EMEA5 barOil and GasDegree of filtration determined by multipass test according to ISO 16889.Inline FilteriProtect® EPFForwardersHousing: Iron/SteelHydraulic OilHydraulic Oil FiltersNitrileNo Bypass with 5.0 bar indicator0 to 35 l/minNo bypassG½Visual0 to 3505QIH (High Strenght Microglass)No Bypass with 5.0 bar indicatorG1/205QIH (High Strength Microglass)5 µm
EPF1105QIHBPXG082
Backordered
Hydraulic & Industrial Process Filtration Division EMEAParker450 barFiltrationHydraulic & Industrial Process Filtration Division EMEANo indicatorMarineDegree of filtration determined by multipass test according to ISO 16889.Inline FilteriProtect® EPFPower PacksHousing: Iron/SteelHydraulic OilHydraulic Oil FiltersNitrileNo bypass / No indicator0 to 35 l/minNo bypassG½Plugged with steel plug0 to 3505QIH (High Strenght Microglass)No Bypass / No indicatorG1/205QIH (High Strength Microglass)5 µm
EPF1105QIHBT1MG082
Backordered
Hydraulic & Industrial Process Filtration Division EMEAParker450 barHydraulicsHydraulic & Industrial Process Filtration Division EMEA5 barOil and GasDegree of filtration determined by multipass test according to ISO 16889.Inline FilteriProtect® EPFDeck and Mobile CranesHousing: Iron/SteelHydraulic OilHydraulic Oil FiltersNitrileNo Bypass with 5.0 bar indicator0 to 35 l/minNo bypassG½Electrical NO/NC0 to 3505QIH (High Strenght Microglass)No Bypass with 5.0 bar indicatorG1/205QIH (High Strength Microglass)5 µm
EPF1105QIRBPKG08RFV
Backordered
Hydraulic & Industrial Process Filtration Division EMEAParker450 barFiltrationHydraulic & Industrial Process Filtration Division EMEANo indicatorMaterial HandlingDegree of filtration determined by multipass test according to ISO 16889.Inline FilteriProtect® EPFForwardersHousing: Iron/SteelHydraulic OilHydraulic Oil FiltersNitrile3.50 to 35 l/minReverse flow valve incl. BypassG½Plugged with steel plug0 to 3505QIR (Microglass - Reverse Flow)3.5 barG1/205QIR (Microglass - Reverse Flow)5 µm
EPF1110QIBM3KG081
Backordered
Hydraulic & Industrial Process Filtration Division EMEAParker6500 psi-40 to 100 °CFiltrationHydraulic & Industrial Process Filtration Division EMEA2.5 barAgricultureDegree of filtration determined by multipass test according to ISO 16889.Inline FilteriProtect® EPFWheeled LoadersHousing: Iron/SteelInlineHydraulic OilHydraulic Oil FiltersNitrile3.50 to 40 l/minStandard, incl. BypassG½Visual0 to 4010QI (Microglass)3.5 barG1/210QI (Microglass)10 µm