• Availability & Price
  • Search SKU
Filter by attributes
  • Actuation Type
  • Body Material
  • Configuration
  • Division
  • Filter Efficiency Rating
  • For Fluid Type
  • Function
  • Maximum Ambient Temperature
  • Maximum Flow Rate
  • Maximum Fluid Temperature
More Filters...

Directional Control Valve with Inductive Position Control - Series D1VW

Picture for category Directional Control Valve with Inductive Position Control - Series D1VW

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s direct operated directional control valve series D1VW with inductive position control in NG06 (CETOP 03 / NFPA D03) features low energy losses due to optimized flow passages. It offers high functional limits up to 80 l/min and a maximum pressure of 350 bar.

This on/off valve is typically used in safety relevant applications. It complies with the machinery directive 2006/42/EG for use as clamping valve according to EN 201:2010. The start or the end position can be monitored. The position control is available for single and double solenoid valves.

Markets:
• Industrial
• Molding

Features/Benefits:
• High functional limits – low forces resulting in safe operation also at high flow rates
• Low pressure drop – resulting in low energy losses in operation
• Wide product offering – many different options – all valves from one single source
• Short delivery time – no warehousing necessary

Applications:
• All types of safety relevant applications
• Injection molding (safety component according to machinery directive 2006/42/EG)

Attention:
The adjustment of the position control is factory set and sealed. Replacement and repairs can only be undertaken by Parker.

The fail-safe position of the directional valve during power failure is the spring offset or center position.
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPartner AvailablePriceDivisionMaximum Operating TemperatureMinimum Operating TemperatureSeal MaterialFor Fluid TypeBody MaterialActuation TypeMaximum Fluid TemperatureMaximum Ambient TemperatureMaximum Kinematic ViscosityWeightFunctionMaximum Flow RateMounting TypeFilter Efficiency RatingMinimum Ambient TemperaturePort ConnectionMaximum Operating PressureConfigurationMinimum Fluid TemperatureMinimum Kinematic ViscositySeal MaterialSpool CodeSpool PositionSolenoid OptionInput VoltagePosition Control Type
D1VW001KVJWI1N
Backordered
Industrial Systems Division Europe60 °C-20 °CFPMWater-GlycolCast IronSolenoid70 °C60 °C400 cSt1.8 kg3-Way80 L/minManifoldISO 4406; 18/16/13-25 °CNG06 / CETOP 03T: 210 barDirectional spool valve-202.8 cStFPM0012 positions, spring offset in position 0, operated in position bWith manual override24 V DCEnd position monitored side A
D1VW001KVJWI4N
Backordered
Industrial Systems Division Europe60 °C-20 °CFPMWater-GlycolCast IronSolenoid70 °C60 °C400 cSt3.8 kg2-way30 to 80 L/minManifoldISO 4406; 18/16/13-25 °CNG06 / CETOP 03T: 210 barDirectional spool valve-202.8 cStFPM0012 positions, spring offset in position 0, operated in position bWith manual override24 V DCStart position monitored side A
D1VW001MNJWI4N
Backordered
Industrial Systems Division Europe60 °C-20 °CNBRHydraulic Oil According to DIN 51524Cast IronSolenoid70 °C60 °C400 cSt1.8 kg3-Way80 L/minManifoldISO 4406; 18/16/13-25 °CNG06 / CETOP 03P, A, B: 350 barDirectional spool valve-202.8 cStNBR0012 positions, operated in position 0, spring offset in postion aWith manual override24 V DCStart position monitored side A
D1VW001MNJWTI4N
Backordered
Industrial Systems Division Europe60 °C-20 °CNBRHydraulic Oil According to DIN 51524Cast IronSolenoid70 °C60 °C400 cSt1.8 kg3-Way80 L/minManifoldISO 4406; 18/16/13-25 °CNG06 / CETOP 03T: 210 barDirectional spool valve-202.8 cStNBR0012 positions, operated in position 0, spring offset in postion aWithout manual override24 V DCStart position monitored side A
D1VW002CNGWI6N
Backordered
Industrial Systems Division Europe60 °C-20 °CNBRHydraulic Oil According to DIN 51524Cast IronSolenoid70 °C60 °C400 cSt3.8 kg3-Way80 L/minSub-baseISO 4406; 18/16/13-25 °CNG06 / CETOP 03T: 210 barDirectional spool valve-202.8 cStNBR0023 positions, spring offset in position 0, operated in position a or bWith manual override205 V DCStart positions
D1VW002CNJWI3N
Backordered
Industrial Systems Division Europe60 °C-20 °CNBRHydraulic Oil According to DIN 51524Cast IronSolenoid70 °C60 °C400 cSt3.8 kg3-Way80 L/minManifoldISO 4406; 18/16/13-25 °CNG06 / CETOP 03P, A, B: 350 barDirectional spool valve-202.8 cStNBR0023 positions, spring offset in position 0, operated in position a or bWith manual override24 V DCEnd positions
D1VW002CNJWI6N
Backordered
Industrial Systems Division Europe60 °C-20 °CNBRHydraulic Oil According to DIN 51524Cast IronSolenoid70 °C60 °C400 cSt3.8 kg3-Way80 L/minSub-baseISO 4406; 18/16/13-25 °CNG06 / CETOP 03T: 210 barDirectional spool valve-202.8 cStNBR0023 positions, spring offset in position 0, operated in position a or bWith manual override24 V DCStart positions
D1VW002CNJWTI6N
Backordered
Industrial Systems Division Europe60 °C-20 °CNBRHydraulic Oil According to DIN 51524Cast IronSolenoid70 °C60 °C400 cSt3.8 kg3-Way80 L/minManifoldISO 4406; 18/16/13-25 °CNG06 / CETOP 03P, A, B: 350 barDirectional spool valve-202.8 cStNBR0023 positions, spring offset in position 0, operated in position a or bWithout manual override24 V DCStart positions
D1VW002CVJWI3N
Backordered
Industrial Systems Division Europe60 °C-20 °CFPMWater-GlycolCast IronSolenoid70 °C60 °C400 cSt3.8 kg3-Way80 L/minManifoldISO 4406; 18/16/13-25 °CNG06 / CETOP 03T: 210 barDirectional spool valve-202.8 cStFPM0023 positions, spring offset in position 0, operated in position a or bWith manual override24 V DCEnd positions
D1VW002CVJWI6N
Backordered
Industrial Systems Division Europe60 °C-20 °CFPMWater-GlycolCast IronSolenoid70 °C60 °C400 cSt3.8 kg3-Way80 L/minSub-baseISO 4406; 18/16/13-25 °CNG06 / CETOP 03P, A, B: 350 barDirectional spool valve-202.8 cStFPM0023 positions, spring offset in position 0, operated in position a or bWith manual override24 V DCStart positions
D1VW002ENGWI5N
Backordered
Industrial Systems Division Europe60 °C-20 °CNBRHydraulic Oil According to DIN 51524Cast IronSolenoid70 °C60 °C400 cSt1.8 kg3-Way80 L/minManifoldISO 4406; 18/16/13-25 °CNG06 / CETOP 03T: 210 barDirectional spool valve-202.8 cStNBR0022 positions, spring offset in position 0, operated in position aWith manual override205 V DCStart position monitored side B
D1VW002ENJWI2N
Backordered
Industrial Systems Division Europe60 °C-20 °CNBRHydraulic Oil According to DIN 51524Cast IronSolenoid70 °C60 °C400 cSt1.8 kg3-Way80 L/minSub-baseISO 4406; 18/16/13-25 °CNG06 / CETOP 03P, A, B: 350 barDirectional spool valve-202.8 cStNBR0022 positions, spring offset in position 0, operated in position aWith manual override24 V DCEnd position monitored side B
D1VW002ENJWTI5N
Backordered
Industrial Systems Division Europe60 °C-20 °CNBRHydraulic Oil According to DIN 51524Cast IronSolenoid70 °C60 °C400 cSt1.8 kg3-Way80 L/minSub-baseISO 4406; 18/16/13-25 °CNG06 / CETOP 03P, A, B: 350 barDirectional spool valve-202.8 cStNBR0022 positions, spring offset in position 0, operated in position aWithout manual override24 V DCStart position monitored side B
D1VW002ENUWI5N
Backordered
Industrial Systems Division Europe60 °C-20 °CNBRHydraulic Oil According to DIN 51524Cast IronSolenoid70 °C60 °C400 cSt1.8 kg3-Way80 L/minManifoldISO 4406; 18/16/13-25 °CNG06 / CETOP 03P, A, B: 350 barDirectional spool valve-202.8 cStNBR0022 positions, spring offset in position 0, operated in position aWith manual override98 V DCStart position monitored side B
D1VW002EVJWI5N
Backordered
Industrial Systems Division Europe60 °C-20 °CFPMWater-GlycolCast IronSolenoid70 °C60 °C400 cSt1.8 kg3-Way80 L/minManifoldISO 4406; 18/16/13-25 °CNG06 / CETOP 03T: 210 barDirectional spool valve-202.8 cStFPM0022 positions, spring offset in position 0, operated in position aWith manual override24 V DCStart position monitored side B
D1VW002EVJWTI5N
Backordered
Industrial Systems Division Europe60 °C-20 °CFPMWater-GlycolCast IronSolenoid70 °C60 °C400 cSt1.8 kg3-Way80 L/minManifoldISO 4406; 18/16/13-25 °CNG06 / CETOP 03T: 210 barDirectional spool valve-202.8 cStFPM0022 positions, spring offset in position 0, operated in position aWithout manual override24 V DCStart position monitored side B
D1VW002KNJWI4N
Backordered
Industrial Systems Division Europe60 °C-20 °CNBRHydraulic Oil According to DIN 51524Cast IronSolenoid70 °C60 °C400 cSt1.8 kg3-Way80 L/minManifoldISO 4406; 18/16/13-25 °CNG06 / CETOP 03T: 210 barDirectional spool valve-202.8 cStNBR0022 positions, spring offset in position 0, operated in position bWith manual override24 V DCStart position monitored side A
D1VW002KNJWTI4N
Backordered
Industrial Systems Division Europe60 °C-20 °CNBRHydraulic Oil According to DIN 51524Cast IronSolenoid70 °C60 °C400 cSt1.8 kg3-Way80 L/minSub-baseISO 4406; 18/16/13-25 °CNG06 / CETOP 03T: 210 barDirectional spool valve-202.8 cStNBR0022 positions, spring offset in position 0, operated in position bWithout manual override24 V DCStart position monitored side A
D1VW002KNUWI4N
Backordered
Industrial Systems Division Europe60 °C-20 °CNBRHydraulic Oil According to DIN 51524Cast IronSolenoid70 °C60 °C400 cSt1.8 kg3-Way80 L/minManifoldISO 4406; 18/16/13-25 °CNG06 / CETOP 03T: 210 barDirectional spool valve-202.8 cStNBR0022 positions, spring offset in position 0, operated in position bWith manual override98 V DCStart position monitored side A
D1VW003CNGWI6N
Backordered
Industrial Systems Division Europe60 °C-20 °CNBRHydraulic Oil According to DIN 51524Cast IronSolenoid70 °C60 °C400 cSt3.8 kg3-Way30 to 80 L/minManifoldISO 4406; 18/16/13-25 °CNG06 / CETOP 03P, A, B: 350 barDirectional spool valve-202.8 cStNBR0033 positions, spring offset in position 0, operated in position a or bWith manual override205 V DCStart positions