Directional Control Valve - Series D1MW

Picture for category Directional Control Valve - Series D1MW

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker's direct operated directional control valves series D1MW (NG06 / CETOP 03 / NFPA D03) feature an excellent corrosion protection of the valve body, the solenoid coil and the anchor tube which predestines these on/off valves for mobile applications.

The D1MW is based on the D1VW series. The 3-chamber valve is direct operated by wet pin solenoids. They provide the typical solenoid connections for the mobile market such as AMP Junior Timer and DT04-2P “Deutsch”.

Markets:
• Mobile

Features/Benefits:
• Robust design - ideal for rough applications
• Wide range of spools and connectors - universally applicable, fits all hydraulic systems
• Anti corrosion coating according to DIN EN ISO 9227 NSS, optional - excellent surface protection
• Extended manual override with rubber cover, optional
• Short delivery time - no warehousing necessary

Applications:
• Construction equipment
• Material handling equipment
• Agriculture machinery
• Forestry equipment
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPartner AvailablePriceDivisionMaximum Operating TemperatureMaximum Operating PressureMounting TypeSeal MaterialWeightBody MaterialFor Fluid TypeOperation TypeMounting PositionActuation TypeMinimum Operating TemperatureFunctionMaximum Flow RateProduct SeriesSeal MaterialMarkingPort ConnectionSpool CodeSpool PositionSolenoid OptionSolenoid ConnectionSignal InputNominal SizeCorrosion Resistance Included
D1MW001CNJA
Backordered
Industrial Systems Division Europe60 °C350 barSubplateNBR2.1 kgCast IronHydraulic Oil According to DIN 51524DirectUnrestrictedSolenoid-25 °C3-Way80 L/minDirectional Control ValveNBRStandardNG06 / CETOP 030013 positions, spring offset in position 0, operated in position a or bStandard solenoid2-pin AMP Junior Timer24 VNG06 / CETOP 03Standard surface protection
D1MW001CNJAW
Backordered
Industrial Systems Division Europe60 °C350 barSubplateNBRCast IronHydraulic Oil According to DIN 51524DirectPreferably HorizontalSolenoid-25 °C3-Way80 L/minDirectional Control ValveNBRStandardNG06 / CETOP 030013 positions, spring offset in position 0, operated in position a or bExtended manual override with rubber cover2-pin AMP Junior Timer24 VNG06 / CETOP 03Standard surface protection
D1MW001CNJJ
Backordered
Industrial Systems Division Europe60 °C350 barSubplateNBR2.1 kgCast IronHydraulic Oil According to DIN 51524DirectPreferably HorizontalSolenoid-25 °C3-Way80 L/minDirectional Control ValveNBRStandardNG06 / CETOP 030013 positions, spring offset in position 0, operated in position a or bStandard solenoidDT04-2P24 VNG06 / CETOP 03Standard surface protection
D1MW001CNJJ1P
Backordered
Industrial Systems Division Europe60 °C350 barSubplateNBR2.1 kgCast IronHydraulic Oil According to DIN 51524DirectUnrestrictedSolenoid-25 °C3-Way80 L/minDirectional Control ValveNBRStandardNG06 / CETOP 030013 positions, spring offset in position 0, operated in position a or bStandard solenoidDT04-2P24 VNG06 / CETOP 03Anti corrosion coating
D1MW001CNJJW
Backordered
Industrial Systems Division Europe60 °C350 barSubplateNBR2.1 kgCast IronHydraulic Oil According to DIN 51524DirectPreferably HorizontalSolenoid-25 °C3-Way80 L/minDirectional Control ValveNBRStandardNG06 / CETOP 030013 positions, spring offset in position 0, operated in position a or bExtended manual override with rubber coverDT04-2P24 VNG06 / CETOP 03Standard surface protection
D1MW001CNJJW1P
Backordered
Industrial Systems Division Europe60 °C350 barSubplateNBR2.1 kgCast IronHydraulic Oil According to DIN 51524DirectUnrestrictedSolenoid-25 °C3-Way80 L/minDirectional Control ValveNBRStandardNG06 / CETOP 030013 positions, spring offset in position 0, operated in position a or bExtended manual override with rubber coverDT04-2P24 VNG06 / CETOP 03Anti corrosion coating
D1MW001CNJW1P
Backordered
Industrial Systems Division Europe60 °C350 barSubplateNBR2.1 kgCast IronHydraulic Oil According to DIN 51524DirectPreferably HorizontalSolenoid-25 °C3-Way80 L/minDirectional Control ValveNBRStandardNG06 / CETOP 030013 positions, spring offset in position 0, operated in position a or bStandard solenoidEN 175301-80324 VNG06 / CETOP 03Anti corrosion coating
D1MW001CNJWW
Backordered
Industrial Systems Division Europe60 °C350 barSubplateNBR2.1 kgCast IronHydraulic Oil According to DIN 51524DirectUnrestrictedSolenoid-25 °C3-Way80 L/minDirectional Control ValveNBRStandardNG06 / CETOP 030013 positions, spring offset in position 0, operated in position a or bExtended manual override with rubber coverEN 175301-80324 VNG06 / CETOP 03Standard surface protection
D1MW001CNJWW1P
Backordered
Industrial Systems Division Europe60 °C350 barSubplateNBR2.1 kgCast IronHydraulic Oil According to DIN 51524DirectUnrestrictedSolenoid-25 °C3-Way80 L/minDirectional Control ValveNBRStandardNG06 / CETOP 030013 positions, spring offset in position 0, operated in position a or bExtended manual override with rubber coverEN 175301-80324 VNG06 / CETOP 03Anti corrosion coating
D1MW001CNKA
Backordered
Industrial Systems Division Europe60 °C350 barSubplateNBR2.1 kgCast IronHydraulic Oil According to DIN 51524DirectUnrestrictedSolenoid-25 °C3-Way80 L/minDirectional Control ValveNBRStandardNG06 / CETOP 030013 positions, spring offset in position 0, operated in position a or bStandard solenoid2-pin AMP Junior Timer12 VNG06 / CETOP 03Standard surface protection
D1MW001CNKJ
Backordered
Industrial Systems Division Europe60 °C350 barSubplateNBR2.1 kgCast IronHydraulic Oil According to DIN 51524DirectPreferably HorizontalSolenoid-25 °C3-Way80 L/minDirectional Control ValveNBRStandardNG06 / CETOP 030013 positions, spring offset in position 0, operated in position a or bStandard solenoidDT04-2P12 VNG06 / CETOP 03Standard surface protection
D1MW001CNKJW1P
Backordered
Industrial Systems Division Europe60 °C350 barSubplateNBR2.1 kgCast IronHydraulic Oil According to DIN 51524DirectUnrestrictedSolenoid-25 °C3-Way80 L/minDirectional Control ValveNBRStandardNG06 / CETOP 030013 positions, spring offset in position 0, operated in position a or bExtended manual override with rubber coverDT04-2P12 VNG06 / CETOP 03Anti corrosion coating
D1MW001CNKW1P
Backordered
Industrial Systems Division Europe60 °C350 barSubplateNBR2.1 kgCast IronHydraulic Oil According to DIN 51524DirectPreferably HorizontalSolenoid-25 °C3-Way80 L/minDirectional Control ValveNBRStandardNG06 / CETOP 030013 positions, spring offset in position 0, operated in position a or bStandard solenoidEN 175301-80312 VNG06 / CETOP 03Anti corrosion coating
D1MW001CNKWW
Backordered
Industrial Systems Division Europe60 °C350 barSubplateNBR2.1 kgCast IronHydraulic Oil According to DIN 51524DirectPreferably HorizontalSolenoid-25 °C3-Way80 L/minDirectional Control ValveNBRStandardNG06 / CETOP 030013 positions, spring offset in position 0, operated in position a or bExtended manual override with rubber coverEN 175301-80312 VNG06 / CETOP 03Standard surface protection
D1MW001CVJW1P
Backordered
Industrial Systems Division Europe60 °C350 barSubplateFPM2.1 kgCast IronWater-GlycolDirectUnrestrictedSolenoid-25 °C3-Way80 L/minDirectional Control ValveFPMStandardNG06 / CETOP 030013 positions, spring offset in position 0, operated in position a or bStandard solenoidEN 175301-80324 VNG06 / CETOP 03Anti corrosion coating
D1MW001CVJWT1P
Backordered
Industrial Systems Division Europe60 °C350 barSubplateFPM2.1 kgCast IronWater-GlycolDirectUnrestrictedSolenoid-25 °C3-Way80 L/minDirectional Control ValveFPMStandardNG06 / CETOP 030013 positions, spring offset in position 0, operated in position a or bWithout manual overrideEN 175301-80324 VNG06 / CETOP 03Anti corrosion coating
D1MW001CVJWW
Backordered
Industrial Systems Division Europe60 °C350 barSubplateFPM2.1 kgCast IronWater-GlycolDirectPreferably HorizontalSolenoid-25 °C3-Way80 L/minDirectional Control ValveFPMStandardNG06 / CETOP 030013 positions, spring offset in position 0, operated in position a or bExtended manual override with rubber coverEN 175301-80324 VNG06 / CETOP 03Standard surface protection
D1MW001ENJA
Backordered
Industrial Systems Division Europe60 °C350 barSubplateNBR1.5 kgCast IronHydraulic Oil According to DIN 51524DirectPreferably HorizontalSolenoid-25 °C2-way80 L/minDirectional Control ValveNBRStandardNG06 / CETOP 030012 positions, spring offset in position 0, operated in position aStandard solenoid2-pin AMP Junior Timer24 VNG06 / CETOP 03Standard surface protection
D1MW001ENJAW
Backordered
Industrial Systems Division Europe60 °C350 barSubplateNBR1.5 kgCast IronHydraulic Oil According to DIN 51524DirectUnrestrictedSolenoid-25 °C2-way80 L/minDirectional Control ValveNBRStandardNG06 / CETOP 030012 positions, spring offset in position 0, operated in position aExtended manual override with rubber cover2-pin AMP Junior Timer24 VNG06 / CETOP 03Standard surface protection
D1MW001ENJJ
Backordered
Industrial Systems Division Europe60 °C350 barSubplateNBR1.5 kgCast IronHydraulic Oil According to DIN 51524DirectPreferably HorizontalSolenoid-25 °C2-way80 L/minDirectional Control ValveNBRStandardNG06 / CETOP 030012 positions, spring offset in position 0, operated in position aStandard solenoidDT04-2P24 VNG06 / CETOP 03Standard surface protection