Direct Operated Proportional Directional Control Valve - Series D1FC / D3FC

Picture for category Direct Operated Proportional Directional Control Valve - Series D1FC / D3FC

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The direct operated proportional DC valves series D1FC (NG06/ CETOP 03) and D3FC (NG10/CETOP 05) with digital onboard electronics and position feedback provides optimized process speed with high dynamics and flow for various applications. The LVDT is completely integrated into the compact housing,  therefore it does not require an exposed cable connection. Thus an unintended disconnection is impossible. The digital onboard electronics is situated in a robust metal housing, which allows the usage under rough environmental conditions. The nominal values are factory set. The cable connection to a serial RS232 interface is available as accessory.

Optionally available with EtherCAT® interface
The D1FC and D3FC with EtherCAT® interface  fulfill the requirements  of  modern communication between valve and main control. Due to high data transmission speed and short cycle times, also demanding control functions can be realized within the fieldbus system.

The valve is actuated and monitored by the EtherCAT® interface. Actual value (spool position), temperature, operating hours and different error messages are available as diagnostic signals. The valve parameters are factory set  and can be adapted with the Parker ProPxD software via the parametrizing interface.

In addition to the fieldbus communication, the valves provide the range of functions of the standard version including  analogue  command  signal  and  diagnostic  spare stroke. Thus they can be operated independent of the fieldbus control, particularly during commissioning and maintenance.

Markets:
• Industrial
• Power generation
• Machine tools
• Molding
• Rubber & tire processing

Features/benefits:
• High level of dynamics and flows - optimized process speed
• Very good repeatability - improved process and product accuracy
• Fully integrated position feedback system - protection from mechanical external influences, resulting in lower down times
• Position feedback sensor positioned directly on the spool - very precise measurements, resulting in improved process accuracy
• Digital electronics - can be easily adapted to the application, resulting in flexible use
• Short delivery time - no storage necessary
• Compact dimensions - for use in particularly confined conditions
• With EtherCAT® interface upon request - high data speeds, short cycle times
• Progressive flow characteristics for sensitive adjustment

Applications:
• Machine tool
• General presses
• Tire presses
Read More...
View as Grid List
Sort by
Display per page
ActionSKUAvailabilityPartner AvailablePriceDivisionMaximum Operating PressureSeal MaterialBody MaterialMaximum Flow RateMounting PositionMinimum Fluid TemperatureMaximum Ambient TemperatureMaximum Kinematic ViscosityMinimum Ambient TemperatureActuation TypeFunctionFor Fluid TypeMinimum Kinematic ViscosityFilter Efficiency RatingMaximum Fluid TemperatureMounting StyleElectronics TypePower Supply VoltageIngress Protection RatingVariation of Opening PointLeak RateHysteresisResponse TimeVibration ResistanceSeal MaterialMarkingPort ConnectionFlow RateConnection TypeSpool TypeSignal InputFunctionSignal OutputSpool CodeDefined Spool Position At Power DownMaximum Operating TemperatureMinimum Operating TemperatureFlow RateMounting TypeBrandTechnologyOperation TypeApplicationMediaWeightValve TypeDivisionProduct SeriesPressure DifferentialSpool Design
D1FCE50FC9NB03
Backordered
Industrial Systems Division Europe350 barNBRCast Ironn/aUnrestricted-25 °C60 °C400 cSt-20 °CProportional3-WayHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboard18...30, electric shut-off at < 17, ripple < 5 % eff., surge free VIP65 in accordance with EN 60529set to 10 % command signal<800 (zerolap spool)< 0,1 %20 ms15 Shock Acc. IEC 68-2-27NBRStandardNG06 / CETOP 0310 l/min6 + PEZerolap0 to ±10 V0 to 10 V = P-A+10...0...-10 VE50, equal metering, 4-way, 3 position, all ports open, meteredna
D1FCE50FC9NB73
Backordered
Industrial Systems Division Europe350 barNBRCast Ironn/aUnrestricted-25 °C60 °C400 cSt-20 °CProportional3-WayHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboard18...30, electric shut-off at < 17, ripple < 5 % eff., surge free VIP65 in accordance with EN 60529set to 10 % command signal<800 (zerolap spool)< 0,1 %20 ms10 Sinus 5...2000 Hz Acc. IEC 68-2-6NBRStandardNG06 / CETOP 0310 l/min6 + PE + enableZerolap0 to ±10 V0 to 10 V = P-A+10...0...-10 VE50, equal metering, 4-way, 3 position, all ports open, meteredCenter position60 °C-20 °Cn/aSubplateParkerHydraulicsDirectIndustrial HydraulicHydraulic Oil3.4 kgProportional DC ValveIndustrial Systems Division EuropeProportional DC Valve5 barSpool/body
D1FCE50FC9NS03
Backordered
Industrial Systems Division Europe350 barNBRCast Ironn/aUnrestricted-25 °C60 °C400 cSt-20 °CSolenoid3-WayHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboard18...30, electric shut-off at < 17, ripple < 5 % eff., surge free VIP65 in accordance with EN 60529set to 10 % command signal<800 (zerolap spool)< 0,1 %20 ms10 (RMS) Random Noise 20...2000 Hz Acc. IEC 68-2-36NBRStandardNG06 / CETOP 0310 l/min6 + PEZerolap4 to 20 mA12 to 20 mA = P-A+10...0...-10 VE50, equal metering, 4-way, 3 position, all ports open, meteredCenter positionSubplateDirect3.4 kgProportional DC Valve5 barSpool/body
D1FCE50FC9NS73
Backordered
Industrial Systems Division Europe350 barNBRCast Ironn/aUnrestricted-25 °C60 °C400 cSt-20 °CProportional3-WayHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboard18...30, electric shut-off at < 17, ripple < 5 % eff., surge free VIP65 in accordance with EN 60529set to 10 % command signal<800 (zerolap spool)< 0,1 %20 ms15 Shock Acc. IEC 68-2-27NBRStandardNG06 / CETOP 0310 l/min6 + PE + enableZerolap4 to 20 mA12 to 20 mA = P-A+10...0...-10 VE50, equal metering, 4-way, 3 position, all ports open, meteredna
D1FCE50HA9NB03
Backordered
Industrial Systems Division Europe350 barNBRCast Ironn/aUnrestricted-25 °C60 °C400 cSt-20 °CProportional3-WayHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboard18...30, electric shut-off at < 17, ripple < 5 % eff., surge free VIP65 in accordance with EN 60529set to 10 % command signal<800 (zerolap spool)< 0,1 %20 ms10 (RMS) Random Noise 20...2000 Hz Acc. IEC 68-2-36NBRStandardNG06 / CETOP 0320 l/min6 + PEZerolap0 to ±10 V0 to 10 V = P-A+10...0...-10 VE50, equal metering, 4-way, 3 position, all ports open, meteredP to ASubplateDirect3.4 kgProportional DC Valve5 barSpool/body
D1FCE50HA9NS03
Backordered
Industrial Systems Division Europe350 barNBRCast Ironn/aUnrestricted-25 °C60 °C400 cSt-20 °CProportional3-WayHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboard18...30, electric shut-off at < 17, ripple < 5 % eff., surge free VIP65 in accordance with EN 60529set to 10 % command signal<800 (zerolap spool)< 0,1 %20 ms10 (RMS) Random Noise 20...2000 Hz Acc. IEC 68-2-36NBRStandardNG06 / CETOP 0320 l/min6 + PEZerolap4 to 20 mA12 to 20 mA = P-A+10...0...-10 VE50, equal metering, 4-way, 3 position, all ports open, meteredP to ASubplateDirect3.4 kgProportional DC Valve5 barSpool/body
D1FCE50HA9VB03
Backordered
Industrial Systems Division Europe350 barFPMCast Ironn/aUnrestricted-20 °C60 °C400 cSt-20 °CProportional3-WayWater-Glycol20 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboard18...30, electric shut-off at < 17, ripple < 5 % eff., surge free VIP65 in accordance with EN 60529set to 10 % command signal<800 (zerolap spool)< 0,1 %20 ms10 (RMS) Random Noise 20...2000 Hz Acc. IEC 68-2-36FPMStandardNG06 / CETOP 0320 l/min6 + PEZerolap0 to ±10 V0 to 10 V = P-A+10...0...-10 VE50, equal metering, 4-way, 3 position, all ports open, meteredP to ASubplateDirect3.4 kgProportional DC Valve5 barSpool/body
D1FCE50HA9VS03
Backordered
Industrial Systems Division Europe350 barFPMCast Ironn/aUnrestricted-20 °C60 °C400 cSt-20 °CSolenoid3-WayWater-Glycol20 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboard18...30, electric shut-off at < 17, ripple < 5 % eff., surge free VIP65 in accordance with EN 60529set to 10 % command signal<800 (zerolap spool)< 0,1 %20 ms10 Sinus 5...2000 Hz Acc. IEC 68-2-6FPMStandardNG06 / CETOP 0320 l/min6 + PEZerolap4 to 20 mA12 to 20 mA = P-A+10...0...-10 VE50, equal metering, 4-way, 3 position, all ports open, meteredP to ASubplateDirect3.4 kgProportional DC Valve5 barSpool/body
D1FCE50HB9NB03
Backordered
Industrial Systems Division Europe350 barNBRCast Ironn/aUnrestricted-25 °C60 °C400 cSt-20 °CSolenoid3-WayHydraulic Oil20 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboard18...30, electric shut-off at < 17, ripple < 5 % eff., surge free VIP65 in accordance with EN 60529set to 10 % command signal<800 (zerolap spool)< 0,1 %20 ms10 Sinus 5...2000NBRStandardNG06 / CETOP 0320 l/min6 + PEZerolap0 to ±10 V0 to 10 V = P-A+10...0...-10 VE50, equal metering, 4-way, 3 position, all ports open, meteredP to B
D1FCE50HB9NB73
Backordered
Industrial Systems Division Europe350 barNBRCast Ironn/aUnrestricted-25 °C60 °C400 cSt-20 °CProportional3-WayHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboard18...30, electric shut-off at < 17, ripple < 5 % eff., surge free VIP65 in accordance with EN 60529set to 10 % command signal<800 (zerolap spool)< 0,1 %20 ms15 Shock Acc. IEC 68-2-27NBRStandardNG06 / CETOP 0320 l/min6 + PE + enableZerolap0 to ±10 V0 to 10 V = P-A+10...0...-10 VE50, equal metering, 4-way, 3 position, all ports open, meteredP to B
D1FCE50HB9VB03
Backordered
Industrial Systems Division Europe350 barFPMCast Ironn/aUnrestricted-20 °C60 °C400 cSt-20 °CProportional3-WayWater-Glycol20 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboard18...30, electric shut-off at < 17, ripple < 5 % eff., surge free VIP65 in accordance with EN 60529set to 10 % command signal<800 (zerolap spool)< 0,1 %20 ms10 (RMS) Random Noise 20...2000 Hz Acc. IEC 68-2-36FPMStandardNG06 / CETOP 0320 l/min6 + PEZerolap0 to ±10 V0 to 10 V = P-A+10...0...-10 VE50, equal metering, 4-way, 3 position, all ports open, meteredP to BSubplateDirect3.4 kgProportional DC Valve5 barSpool/body
D1FCE50HB9VS03
Backordered
Industrial Systems Division Europe350 barFPMCast Ironn/aUnrestricted-20 °C60 °C400 cSt-20 °CProportional3-WayWater-Glycol20 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboard18...30, electric shut-off at < 17, ripple < 5 % eff., surge free VIP65 in accordance with EN 60529set to 10 % command signal<800 (zerolap spool)< 0,1 %20 ms15 Shock Acc. IEC 68-2-27FPMStandardNG06 / CETOP 0320 l/min6 + PEZerolap4 to 20 mA12 to 20 mA = P-A+10...0...-10 VE50, equal metering, 4-way, 3 position, all ports open, meteredP to BSubplateDirect3.4 kgProportional DC Valve5 barSpool/body
D1FCE50HC9NB03
Backordered
Industrial Systems Division Europe350 barNBRCast Ironn/aUnrestricted-25 °C60 °C400 cSt-20 °CSolenoid3-WayHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboard18...30, electric shut-off at < 17, ripple < 5 % eff., surge free VIP65 in accordance with EN 60529set to 10 % command signal<800 (zerolap spool)< 0,1 %20 ms10 Sinus 5...2000 Hz Acc. IEC 68-2-6NBRStandardNG06 / CETOP 0320 l/min6 + PEZerolap0 to ±10 V0 to 10 V = P-A+10...0...-10 VE50, equal metering, 4-way, 3 position, all ports open, meteredna
D1FCE50HC9NB73
Backordered
Industrial Systems Division Europe350 barNBRCast Ironn/aUnrestricted-25 °C60 °C400 cSt-20 °CSolenoid3-WayHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboard18...30, electric shut-off at < 17, ripple < 5 % eff., surge free VIP65 in accordance with EN 60529set to 10 % command signal<800 (zerolap spool)< 0,1 %20 ms10 Sinus 5...2000 Hz Acc. IEC 68-2-6NBRStandardNG06 / CETOP 0320 l/min6 + PE + enableZerolap0 to ±10 V0 to 10 V = P-A+10...0...-10 VE50, equal metering, 4-way, 3 position, all ports open, meteredCenter positionSubplateDirect3.4 kgProportional DC Valve5 barSpool/body
D1FCE50KA9NB03
Backordered
Industrial Systems Division Europe350 barNBRCast Ironn/aUnrestricted-25 °C60 °C400 cSt-20 °CSolenoid3-WayHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboard18...30, electric shut-off at < 17, ripple < 5 % eff., surge free VIP65 in accordance with EN 60529set to 10 % command signal<800 (zerolap spool)< 0,1 %20 ms10 Sinus 5...2000 Hz Acc. IEC 68-2-6NBRStandardNG06 / CETOP 0330 l/min6 + PEZerolap0 to ±10 V0 to 10 V = P-A+10...0...-10 VE50, equal metering, 4-way, 3 position, all ports open, meteredP to ASubplateDirect3.4 kgProportional DC Valve5 barSpool/body
D1FCE50KA9NB73
Backordered
Industrial Systems Division Europe350 barNBRCast Ironn/aUnrestricted-25 °C60 °C400 cSt-20 °CProportional3-WayHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboard18...30, electric shut-off at < 17, ripple < 5 % eff., surge free VIP65 in accordance with EN 60529set to 10 % command signal<800 (zerolap spool)< 0,1 %20 ms10 (RMS) Random Noise 20...2000 Hz Acc. IEC 68-2-36NBRStandardNG06 / CETOP 0330 l/min6 + PE + enableZerolap0 to ±10 V0 to 10 V = P-A+10...0...-10 VE50, equal metering, 4-way, 3 position, all ports open, meteredP to ASubplateDirect3.4 kgProportional DC Valve5 barSpool/body
D1FCE50KA9NN03
Backordered
Industrial Systems Division Europe350 barNBRCast Ironn/aUnrestricted-25 °C60 °C400 cSt-20 °CProportional3-WayHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboard18...30, electric shut-off at < 17, ripple < 5 % eff., surge free VIP65 in accordance with EN 60529set to 10 % command signal<800 (zerolap spool)< 0,1 %20 ms15 Shock Acc. IEC 68-2-27NBRStandardNG06 / CETOP 0330 l/min6 + PEZerolapEtherCAT bus type N0 to 4096 = P-A+10...0...-10 VE50, equal metering, 4-way, 3 position, all ports open, meteredP to ASubplateDirect3.4 kgProportional DC Valve5 barSpool/body
D1FCE50KA9VS03
Backordered
Industrial Systems Division Europe350 barFPMCast Ironn/aUnrestricted-20 °C60 °C400 cSt-20 °CProportional3-WayWater-Glycol20 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboard18...30, electric shut-off at < 17, ripple < 5 % eff., surge free VIP65 in accordance with EN 60529set to 10 % command signal<800 (zerolap spool)< 0,1 %20 ms10 Sinus 5...2000 Hz Acc. IEC 68-2-6FPMStandardNG06 / CETOP 0330 l/min6 + PEZerolap4 to 20 mA12 to 20 mA = P-A+10...0...-10 VE50, equal metering, 4-way, 3 position, all ports open, meteredP to ASubplateDirect3.4 kgProportional DC Valve5 barSpool/body
D1FCE50KB9NB73
Backordered
Industrial Systems Division Europe350 barNBRCast Ironn/aUnrestricted-25 °C60 °C400 cSt-20 °CSolenoid3-WayHydraulic Oil According to DIN 51524 ... 53520 cStISO 4406; 18/16/1360 °CDIN 24340 / ISO 4401 / CETOP RP121 / NFPAOnboard18...30, electric shut-off at < 17, ripple < 5 % eff., surge free VIP65 in accordance with EN 60529set to 10 % command signal<800 (zerolap spool)< 0,1 %20 ms15 Shock Acc. IEC 68-2-27NBRStandardNG06 / CETOP 0330 l/min6 + PE + enableZerolap0 to ±10 V0 to 10 V = P-A+10...0...-10 VE50, equal metering, 4-way, 3 position, all ports open, meteredP to BSubplateDirect3.4 kgProportional DC Valve5 barSpool/body
D1FCE50KB9NS03
Backordered
Industrial Systems Division EuropeDIN 24340 / ISO 4401 / CETOP RP121 / NFPANBRStandardNG06 / CETOP 0330 l/min6 + PEZerolap4 to 20 mA12 to 20 mA = P-A+10...0...-10 VE50, equal metering, 4-way, 3 position, all ports open, meteredP to BDirect