Direct Operated Check Valve, SAE Flange - Series C5V - C5V06-640B1

Parker direct operated check valves series C5V with SAE flange are easy to install and provide high flow rates. They can be mounted either directly on the outlet flange of pumps or on the inlet flange of actuators to achieve a very compact design.
Availability:
Backordered
SKU: C5V06-640B1
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Products specifications
Attribute nameAttribute value
DivisionIndustrial Systems Division EuropeMaximum Operating Temperature60 °C
Minimum Operating Temperature-20 °CConfigurationn/a
Seal MaterialNBRBody MaterialCast Iron
Product SeriesCheck ValveConnection Sizen/a
Operation TypeDirectFlow DirectionA to B
Maximum Flow Rate100 L/minMaximum Operating Pressure420 bar
Weight0.6 kgMounting TypeFlanged according SAE
Actuation TypeMechanicalConnection TypeFlange
Cracking Pressure0.5 bar
Seal MaterialNBRAdditional OptionsNA
Port ConnectionSAE 3/4Seal TypeSealing for port B
DIN Flange SizeSAE62Cracking Pressure0.5 bar
Product resources